For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.68.021 — Definitions

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.68.021

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/e294c6b5-2b02-4623-bb6d-54838df4fc9f

18.68.021 - Definitions.

For the purpose of this chapter, the following definitions shall apply: "Collar joint" is the vertical space between adjacent wythes and may contain mortar. "Crosswall" is a wall that meets the requirements of Subsection 18.68.027.D.3. A crosswall is not a shear wall. "Crosswall shear capacity" is the length of the crosswall times the allowable shear value, v c L 0 . "Diaphragm edge" is the intersection of the horizontal diaphragm and a shear wall. "Diaphragm shear capacity" is the depth of the diaphragm times the allowable shear value, v u D. "Flexible diaphragm" is a diaphragm of wood construction or other construction of similar flexibility. "Normal wall" is a wall perpendicular to the direction of seismic forces. "Open front" is an exterior building wall plane on one side only without vertical elements of the lateral force resisting system in one or more stories. "Pointing" is the partial reconstruction of the bed joints of a URM wall as defined in Standard No. 24-42. (See Section 18.68.222.) "UBC" is the 1988 Edition of the Uniform Building Code as published by the International Conference of Building Officials. "UBC standard" is the 1988 Edition of the Uniform Building Code standard as published by the International Conference of Building Officials. "Unreinforced masonry bearing wall" is URM wall which provides the vertical support for a floor or roof for which the total superimposed load exceeds one hundred (100) pounds per linear foot of wall. "Unreinforced masonry (URM) wall" is a masonry wall in which the area of reinforcing steel is less than twenty five percent (25%) of the minimum required by the UBC for reinforced masonry. "Yield story drift" is the lateral displacement of one level relative to the level above or below at which yield stress is first developed in a frame member.

(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.