18.71.070 - Equivalent lateral force procedure.
A. General. Structures shall be analyzed for prescribed forces acting concurrently on the orthogonal axes of the building. The effects of the loading on the two (2) orthogonal axes shall be combined as required by Subsection 18.71.060.A. B. Base Shear for Analysis. The base shear used to determine story drifts shall be determined using seventy-five percent (75%) of the base shear as determined in accordance with ASCE 7-16 Section 12.8.1. Where: R = 1.4 for concrete frame buildings with masonry infill and all other reinforced concrete buildings. EXCEPTION: R = 1.0 for single-story buildings. The R value in ASCE 7-16 Table 12.2-1 for new building design shall not be used for story drift determination. C. Structure period. The value of T may be determined by either Method A or B as prescribed by ASCE 7-16 Section 12.8.2. The structure period calculated by Method B need not be limited to a percent of the value obtained by Method A. D. Vertical distribution of forces. The base shear shall be distributed over the height of the structure in conformance with Formula (71-6). [image omitted; see the official code] (71-6) Where: C vx = vertical distribution factor to be applied to V to obtain the story force at level x. k = an exponent related to building period as follows: For buildings having a period of 0.4 seconds or less, k = 1.0 For buildings having a period of 2.0 seconds or more, k = 2.0 For buildings having a period between 0.4 and 2.0 seconds, k may be taken as two (2) or determined by linear interpolation between one (1) and two (2). E. Horizontal distribution of shear. The effective stiffness of elements shall be used for the horizontal distribution of shear. F. Horizontal torsional moments. Provision shall be made for increased displacements resulting from horizontal torsion. The effects of torsional moments shall be included in the determination of the effective stiffness of elements and systems. Reinforced concrete floors may be considered as rigid diaphragms. G. Effective stiffness. The effective stiffness of concrete and masonry elements shall be determined as prescribed in Subsection 18.71.060.D. H. Material characteristics. Material characteristics shall be determined as prescribed in Subsection 18.71.060.F. I. Story drift limitations. Story drift limits shall be as prescribed in Subsection 18.71.060.G. J. Compressive strain determination. Compressive strain shall be determined as prescribed in Subsection 18.71.060.H. K. Shear strength limitation. The in-plane shear strength shall equal or exceed the shear forces determined as prescribed in Subsection 18.71.060.I.
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.