§ 6.01.040 — REQUIREMENT FOR LAMP SOURCE AND SHIELDING

Menifee Municipal Code (2026 S-15) · Menifee Municipal Code § 6.01.040

Corpus is an independent public-information project, not the official City of Menifee website. Stable reference: corpuslaw.us/code/d18384ee-fb3f-4faa-9470-7af8f9c7266b

§ 6.01.040 REQUIREMENT FOR LAMP SOURCE AND SHIELDING.

(A) A maximum of 8,100 total lumens per acre or per parcel if under one acre shall be allowed. When lighting is “allowed”, it must be fully shielded if feasible and partially shielded in all other cases, and must be focused to minimize spill light into the night sky and onto adjacent properties. (B) The requirements for lamp source and shielding of light emissions for outdoor light fixtures shall be: Lamp Type and Shielding Requirements per Fixture Class I — Lamp Type Low pressure sodium | Allowed Others above 4,050 lumens | Allowed if fully shielded Others 4,050 lumens and below | Allowed Class II — Parking Lots, Walkways, Security — Lamp Type Low pressure sodium | Allowed Others above 4,050 lumens | Prohibited Others 4,050 lumens and below | Allowed Class III — Decorative — Lamp Type Low pressure sodium | Allowed Others above 4,050 lumens | Prohibited Others 4,050 lumens and below | Allowed (Ord. 2009-24, passed 3-3-2009)