§ 16.24.040 — Application Submittal Requirements
Murrieta Municipal Code (2026 S-23 through Ord. 639-26) · Murrieta Municipal Code § 16.24.040
Corpus is an independent public-information project, not the official City of Murrieta website. Stable reference: corpuslaw.us/code/61eab572-90ff-4b94-97a2-b757a2daf37e
16.24.040 Application Submittal Requirements.
Applications for development shall comply with the submittal requirements of this chapter. When a development project is a specific plan or master development plan, the submittal requirements shall be incorporated in the appropriate sections of the corresponding documents. If adequate detailed studies are provided with the specific plan and/or master development plan, subsequent implementing development applications shall be reviewed for substantial conformance with these plans. Application filing requirements are as follows: A. Natural Features Map. This map shall identify slope banks, ridgelines, canyons, natural drainage courses, United States Geological Survey (U.S.G.S.) blueline streams, rock outcroppings, sensitive biological habitats, cultural resources, and other natural features for the purposes of project review and California Environmental Quality Act (CEQA) analysis. B. Overall Conceptual Grading Plan. An overall conceptual grading plan shall be submitted at a minimum scale of one (1) inch equals twenty (20) feet). The plan shall include the following items: 1. A legend with symbols identifying the following, but not limited to: high point, low point, spot elevations, pad, top of wall, top of footing, top of curb, top of ground surface on both sides of a retaining wall, and planned drainage improvements; 2. A separate map shall be provided with proposed cut and fill areas, depths of these identified areas shown in five-foot topographic lines. Quantities of each cut and fill area shall be identified and calculated as a percentage of the total site area. The cut and fill areas shall be either colored green and red, cross-hatched, or screened to delineate each respective area; 3. Contours for existing and proposed topographic conditions shall be provided within submitted plan exhibits. Existing contours shall be depicted with continuous screened lines and proposed contours shall be depicted as above except with a solid line. Contours shall be shown at minimum intervals of two feet of change in elevation. Elevations of less than two feet shall be depicted with spot elevations; and 4. Additional information as required to assist with review of the project. C. Drainage Map. A conceptual drainage and flood control facilities map describing planned drainage improvements. The map shall utilize city standards or an acceptable alternate as determined by the city engineer or their designee. D. Slope Profile Drawings. Cross-section slope profiles shall be included with the slope analysis. Additional profiles may be required as determined by the city engineer or their designee. The slope profiles shall: 1. Be drawn at the same scale and indexed, or keyed, to the slope analysis map, grading plan, and project site map. Both vertical and horizontal scales shall be indicated; 2. Show existing and proposed topography, structures, and infrastructure. Proposed topography, structures, and infrastructures shall be drawn with a thin, solid line. Existing topography and features shall be drawn with a dashed line; 3. Extend at a minimum of one hundred (100) feet outside the project site boundary to clearly show the impact on adjacent property. Additional distance may be necessary to determine off-site terrain and features; 4. Be drawn along those portions of the subject site where: a. The greatest portion of the site where alteration of existing topography is proposed; b. The most intensive or massive portion of the site where development is proposed (e.g. where structures are proposed); c. Where proposed grading would potentially impact existing natural drainage conditions. 5. At least two of the slope profiles shall be roughly parallel to each other and roughly perpendicular to existing contour lines. At least one other slope profile shall be roughly at a ninety (90) degree angle to the other slope profiles and existing contour lines. E. Indicate Source of Data. Indicate the datum, source, data, and scale. F. Geotechnical Report. A geotechnical and soils report shall be prepared by a registered geotechnical engineer to city standards and provide in sufficient detail to substantiate and support the design concepts presented in the application. Additional environmental technical studies and investigations, including, but not limited to, hydrologic, seismic, access/circulation, cultural, tribal cultural, and biological resources may be required to help in the determination of the buildable area of a subject site for consistency with project review and for California Environmental Quality Act (CEQA) analysis. G. Objective Design Guidelines. Objective design guidelines shall be provided for projects that are to be reviewed by the planning commission. Otherwise, illustrative building elevations showing all sides of the structure shall be provided. H. No Grading Proposed. See 16.24.080 (Exceptions) for applicability. I. Additional Information. The following items may be required if determined necessary by the city engineer or their designee to aid in the analysis of the proposed project: 1. A line of sight or view analysis; 2. Photographic and/or computer-generated graphic renderings; or 3. A topographic model and/or large-scale detailed partial model. (Ord. 638-26 § 10 (part), 2026; Ord. 293 § 1 (part), 2004; Ord. 182 § 2 (part), 1997)
Ask a question about Murrieta law
Corpus searches the Murrieta sections it holds and shows the ones that match, with their citations. Free, no sign-in.
