§ 15.04.3.5025 — CPC Section 912.1 amended
Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.04.3.5025
Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/0d893972-53a1-40c9-be40-f43a47cfc498
15.04.3.5025 - CPC Section 912.1 amended.
In Section 912.1, add the following text at the end of the section: "Listed Studor vents shall be permitted to be installed in outdoor sinks for venting purposes when installed as follows: Individual and branch studor vents shall be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented. Stack-type studor vents shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture being vented. The air admittance valve shall be located within the maximum developed length permitted for the vent."
(Ord. No. 13861, § 4, 9-15-2025)