15.08.230 - Sanitation (HSC Section 17910, et seq.).

A. Dwelling Units, Lodging Houses, and Congregate Residences. Dwelling units, lodging houses, and congregate residences shall be provided with a bathroom equipped with plumbing fixtures consisting of a water closet, lavatory and either a bathtub or a shower receptor. Exception: Vehicular residential facilities authorized for residential occupancy pursuant to the Oakland Planning Code need not contain a bathroom in-unit if the occupants are provided adequate on-site water closet, lavatory, and shower facilities meeting the requirements of Oakland Planning Code Section 17.103.085. B. Hotels and Motels. Hotels and motels or subdivisions thereof where both genders are accommodated shall contain at least two separate toilet facilities that are conspicuously identified for male or female use, each of which contains at least one water closet. Exception: Guest rooms may have one unidentified toilet facility. Additional water closets shall be provided on each floor for each gender at the rate of one for every additional 10 guests, or fractional part thereof, in excess of 10. C. Kitchen. Each dwelling unit shall be provided with a kitchen. Every kitchen shall be provided with an approved kitchen sink, cooking appliance, refrigeration appliance and cabinet for storing food, crockery, cutlery, and cooking utensils. Wooden sinks or sinks of similarly absorbent material shall not be permitted. Drain boards shall be maintained waterproofed. Exception: Vehicular residential facilities authorized for residential occupancy pursuant to the Oakland Planning Code need not contain a kitchen in-unit if the occupants are provided on-site kitchen facilities meeting the requirements of Oakland Planning Code Section 17.103.085. D. Plumbing Fixtures. All plumbing fixtures shall be approved and connected to an approved sanitary sewer. All plumbing fixtures shall be connected to an approved system of potable water supply and provided with hot and cold running water necessary for its normal operation. E. Water Closet Compartments. Walls and floors of water closet compartments, except in dwellings, shall be finished in accordance with the Oakland Building Construction Code. F. Room Separations. Every water closet, bathtub or shower receptor required by this Code shall be installed in a room that will afford privacy to the occupant. G. Sanitary Facilities. All sanitary facilities, including but not limited to plumbing fixtures, sanitary sewer, and garbage receptacles, shall be installed and maintained in a safe and sanitary condition and in accordance with applicable requirements of the Oakland Building Construction Code and Oakland Municipal Code. H. Basements. Window wells for habitable space in basements of residential buildings or structures shall conform to the requirements of the Oakland Building Construction Code. I. Subdivision of Rooms. No portion of any room in a dwelling, dwelling unit, efficiency dwelling unit, housekeeping room, apartment house, lodging house, congregate residence, hotel, or motel shall be enclosed or subdivided, wholly or in part by a curtain, portiere, fixed or movable partition or other contrivance or device so as to reduce the minimum floor area and width required by this Code. J. Guest Room Cooking. Food shall not be cooked or otherwise prepared in a guest room except in a kitchen. Exception: Microwave oven used solely to heat pre-prepared food. K. Prohibited Use. No person shall use or occupy or allow another person to use or occupy any residential or non-residential building or structure or portion thereof for living, sleeping, cooking, or eating purposes unless such space or room or rooms conform with the requirements of this Code for habitable space and of the Oakland Planning Code. L. Lot Drainage. All portions of a lot surrounding a residential or non-residential building or structure, including but not limited to yards, courts, driveways, areaways, parking areas, vent shafts, and passageways, shall be graded and drained to an approved facility to preclude the ponding or retention of surface water. Exception: Group R, Division 3 occupancy. Surface water and its collection system shall not be drained or connected to a sanitary sewer system. M. Lot Surfacing. Whenever necessary for proper sanitation or for the protection of the health of the occupants, portion or portions of a lot surrounding a residential building or structure, including but not limited to yards, courts, driveways, areaways, parking areas, vent shafts, and passageways, shall be surfaced with an approved hardened material such as Portland cement concrete or asphalt concrete. N. Room Finishes. Walls and ceilings of habitable rooms in residential buildings or structures shall be finished, sealed, coated, or covered in an approved manner. Approved materials shall be applied as required to maintain surfaces clean and sanitary. Exterior walls or portions thereof and floors of habitable rooms below surrounding finished grade level shall be maintained waterproof. Walls of courts and vent shafts shall be painted and maintained light-colored. O. Garbage Receptacles. Approved solid waste (garbage) receptacles and adequate collection service for residential and non-residential buildings and structures shall be provided as required by Chapter 8.28 (Solid Waste Collection and Disposal and Recycling) of the Oakland Municipal Code. Garbage receptacles and garbage chutes, shafts, covers, and doors shall be maintained clean and tightly closed. Garbage receptacles shall be stored in an approved location. Garbage chutes and shafts and walls of closets, compartments, and rooms used for storing garbage receptacles in residential and non-residential buildings or structure shall be concrete, concrete block, or lined with galvanized metal. P. Vector Control. 1. General. Every room, corridor, hallway, passageway, stairway, wall, partition, ceiling, floor, skylight, glass window, door, carpet, rug, matting, widow curtain or shade or drapery, water closet compartment, toilet room, bathroom, slop sink room, crawl space, washroom, plumbing fixture, drain, roof, closet, cellar, basement, yard, court, and the premises of every residential and non-residential building or structure shall be kept in every part clean, sanitary, and free from all accumulation debris, filth, rubbish, garbage and other offensive matter, insects, rodents and other vector. Neither any article that is dangerous or detrimental to life and limb or to the health of occupants; nor any feed, hay, straw, excelsior, cotton, paper stock, rags, junk, or any other material that may create a fire hazard or provide harborage for rodents or other vector, shall be kept, stored, or handled in any part of a dwelling, dwelling unit, lodging house, apartment house, congregate residence, hotel, or motel, or of the lot on which such building is located, except upon written permit obtained from the officer or agency authorized by law to issue such permit. 2. Openings and Penetrations. Residential and non-residential buildings or structures used for the following activities or occupancies shall be constructed and maintained impervious to the ingress of insects, rodents, and other vector: a. Group I and Group R, Division 1, and Group R, Division 3 occupancies; b. Storing, processing, packaging, or milling of food, meats, fats, oils, dairy products, hay, straw, grain, or feed; c. Raising or housing chickens, birds, poultry, horses, cows, sheep, goats, swine, or other fowl, animals, livestock, or domestic pets. Foundations and foundation walls shall extend for the full perimeter of building or structure and shall be constructed of concrete or masonry. Exception: Type V construction with a floor area not greater than 120 square feet, provided that the floor joists of such a building or structure have not less than 18 inches clearance above the ground and that the exterior perimeter of the underfloor area is fully open on three or more sides and that the underfloor area is maintained clear and free of storage and of debris, vegetation, and other materials. Foundation wall openings for underfloor access and ventilation shall conform with the requirements of the Oakland Building Construction Code. Chimneys, piping, ducting, and other penetrations of the basement and first floor shall have metal shields which tightly encircle the penetration and underlay the flooring. Stores and warehouses shall have concrete floors. Interior surfaces of exterior walls of stores shall be covered with gypsum wallboard or plaster. Q. Operator. The owner or manager, custodian, housekeeper, or homeowners' association representative or other responsible person shall reside or maintain continuous (24-hour) attendance upon the premises and shall have charge of every hotel or motel with 12 or more guest rooms or apartment house, Joint Live Work Quarters, Conversion Residence Quarters, or residential condominium with sixteen or more dwelling units. A notice displaying the name, address, and telephone number of the owner or the owner's designated agent shall be prominently posted in a conspicuous place on the premises of every apartment house having more than three but less than sixteen dwelling units and every hotel and motel having more than three but less than twelve guest rooms and iii every lodging house having more than three guest rooms. R. All structures shall be maintained free of visible mold due to moisture intrusion from rising of moisture from the ground, action of rain, exposed tops of walls, condensation, defective roof covering, inadequate slopes of roofs, or other construction defects.

(Ord. No. 13719, § 4, 12-20-2022; Ord. No. 13666, § 5(Exh. C), 11-16-2021; Ord. No. 13575, § 5(Exh. A), 12-10-2019; Ord. No. 13407, § 4(Exh. A), 12-13-2016)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.