15.56.300 - Guard rails.

Guard rails at least thirty-six (36) inches in height shall be provided in the following locations: A. Both sides of all exterior stairways and ramps; B. All edges of occupied roof areas; C. Edges of all decks not encompassed by the exterior walls of the houseboat superstructure. Guard rails shall be designed to withstand a twenty (20) pound per foot load applied at the top of the rail. In open type railings intermediate members shall not be spaced more than nine inches apart.

(Prior code § 4-9.30)