For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.101J.050 — Property development standards

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Planning Code § 17.101J.050

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/d7686cab-deec-4469-9569-db8a2a0433d7

17.101J.050 - Property development standards.

A. Zone Specific Standards. Table 17.101J.03 below prescribes development standards specific to individual zones. The number designations in the "Additional Regulations" column refer to the regulations listed at the end of the Table. "—" indicates that a standard is not required in the specified zone. Table 17.101J.03: Property Development Standards Development Standards | Zones | Additional Regulations D-OK-1 | D-OK-2 | D-OK-3 | D-OK-4 | D-OK-5 | D-OK-6 | D-OK-7 Minimum Lot Dimensions Width mean | 42 ft. | 40 ft. | 20 ft. | 25 ft. | 25 ft. | 20 ft. | N/A | 1 Frontage | 25 ft. | 25 ft. | 20 ft. | 25 ft. | 25 ft. | 20 ft. | N/A | 2 Lot area | 3,750 sf. | 2,000 sf. | 5,000 sf. | 4,000 sf. | 4,000 sf. | 2,000 sf. | N/A Minimum/Maximum Setbacks Minimum Front | 15 ft./5 ft. | 8 ft. | 8 ft. | 0 ft. | 20 ft. | 8 ft. | N/A | 3, 4, 5, 6, 10, 12 Minimum Interior Side | 4 ft./5 ft. | 3 ft. per side or a total of 5 ft. | 4 ft. | 0 ft./5 ft. | 20 ft. | 4 ft. | N/A | 7, 8, 10, 19 Minimum Street Side | 5 ft. | 5 ft. | 5 ft. | 0 ft. | 20 ft. | 0 ft. | N/A | 10, 19 Rear | 15 ft. | 12 ft. | N/A | 0 ft./5 ft. | 20 ft. | 0 ft. | N/A | 9, 10, 19 Maximum Density Permitted Density | 1 primary unit per lot | 1 primary unit per lot | 1 unit per 1,600 sf. of lot area on lots 5,000 sf. or greater | 0.50 FAR | 0.50 FAR | 0.15 FAR | N/A | 11 Maximum FAR for Lots with a Footprint Slope >20% | 0.65 | N/A | N/A | N/A | N/A | N/A | N/A | 11 Maximum Lot Coverage (%) | 50% | 55% | 55% | N/A | N/A | N/A | N/A | 11 Heights Maximum wall height primary building | 30 ft. and 2 stories | 35 ft. and 3 stories | 35 ft. | 30 ft. | 42 ft. | 15 ft. | N/A | 12 Maximum pitched roof height primary building | 32 ft. and 2 stories | 35 ft. and 3 stories | 40 ft. | 30 ft. | 46 ft. | 20 ft. | N/A | 12 Maximum height for accessory structures | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 12 Height Regulations for all Lots with a Footprint Slope of >20% or that are terraced or split | See Table 17.101J.04 | N/A | N/A | N/A | N/A | N/A | N/A Minimum Open Space Group Open Space | N/A | N/A | 170 sf. per unit | N/A | N/A | N/A | N/A | 13 Courtyard Regulations | N/A | N/A | See Section 17.108.1 20 | N/A | N/A | N/A | N/A Other Development Standards Parking and driveway location requirements | Yes | Yes | Yes | Yes | No | No | N/A | 14 Ground floor active space requirement | N/A | N/A | N/A | Yes | N/A | N/A | N/A | 15 Minimum ground floor façade glazing | N/A | N/A | N/A | 40 to 70% | N/A | N/A | N/A | 16 Minimum height of ground floor facilities | N/A | N/A | N/A | 12 ft. | N/A | N/A | N/A | 17 Minimum Required Parking | Yes | Yes | Yes | Yes | No | No | N/A | 18 Additional Regulations for Table 17.101J.03: 1. No additional subdivisions other than what was approved in the OKPUD are permitted unless a new planned unit development (PUD) application is submitted pursuant to the procedures in Chapter 17.140. 2. The minimum frontage requirement does not apply to flag lots created as part of the original OKPUD. 3. For lots in the D-OK-1 Zone with a footprint slope of less than twenty percent (20%), the minimum front setback is fifteen (15) feet. For lots in the D-OK-1 Zone with a footprint slope equal to or greater than twenty percent (20%), the minimum front setback is five (5) feet. 4. For residences in the D-OK-2 Zone located off of a shared access facility, the minimum front setback is measured from the edge of the pavement of the common access drive. 5. The minimum front setback for a garage is eighteen (18) feet for lots in the D-OK-1 Zone with a footprint slope equal to or less than twenty percent (20%), and lots in the D-OK-3 Zone. In the D-OK-2 Zone, the minimum front setback for a garage is fifteen (15) feet. The minimum front setback for a garage is five (5) feet for lots in the D-OK-1 Zone with a footprint slope greater than twenty percent (20%). 6. In the D-OK-1, D-OK-2, and D-OK-3 Zones, covered porches are permitted in the front setback; in these zones, covered porches not exceeding one (1) story and structures under thirty (30) inches in height shall have a minimum front setback of three (3) feet. Stairs in these zones are permitted up to the front property line. 7. In the D-OK-2 Zone, the minimum interior side yard is three (3) feet except, for a single-family dwelling unit on a lot with two (2) interior side yards, one (1) of the two (2) interior side yards can be reduced to zero (0) feet without a variance if the other interior side yard is at least five (5) feet. On the ground-floor, only a garage of a maximum length of twenty-four (24) feet is allowed on the interior side without a side yard. Habitable rooms are permitted over such a garage. On the interior side without a side yard, no windows, doors or upper floor balconies or decks are permitted less than three (3) feet of the property line. 8. In the D-OK-1 Zone, the minimum interior side yard is four (4) feet on lots less than six thousand (6,000) square feet. The minimum interior side yard is five (5) feet on all other lots in the D-OK-1 Zone. In the D-OK-4 Zone, there is no minimum interior side yard setback unless the interior side lot line is adjacent to a Residential Zone, in which case the minimum side yard setback is five (5) feet. 9. In the D-OK-2 Zone, the minimum rear setback can be reduced to five (5) feet over a maximum of one-half (½) the width of the developable portion of the lot (i.e., the width not including the applicable side yard setbacks), as shown in the following figure. In the D-OK-4 Zone, there is no minimum rear setback unless the rear lot line is adjacent to a Residential Zone, in which case the rear setback is five (5) feet. [image omitted; see the official code] 10. If there is any ambiguity regarding the required setbacks, the setbacks in the Oak Knoll Design Guidelines shall control. 11. Section 17.103.080 for regulations regarding permitted Accessory Dwelling Units. 12. See Section 17.108.030 for allowed projections above height limits and Section 17.108.020 for increased height limits in certain situations. See Table 17.101J.04 for height regulations for all lots with a footprint slope exceeding twenty percent (20%), or that are terraced or split. In the D-OK-5 Zone, the maximum height is measured from the ground level of the building, and the tower of Club Knoll is an allowed projection above the height limit. Also in the D-OK-5 Zone, for any building other than Club Knoll or a replica of Club Knoll, the height limit is the same as in the D-OK-4 Zone. 13. The per unit Group Open Space requirement can be replaced by 70 square feet of dedicated Private Open Space per unit. All usable Group Open Space shall meet the requirements in Sections 17.126.030.A through 17.126.030.E. Usable Private Open Space shall meet the following requirements: a. Usability. A surface shall be provided which prevents dust and allows convenient use for outdoor activities. Such surface shall be any practicable combination of lawn, garden, flagstone, wood planking, concrete, asphalt, or other serviceable, dust-free surfacing. Slope shall not exceed ten percent (10%). Off-street parking and loading areas, driveways, and service areas shall not be counted as usable open space. Adequate safety railings or other protective devices shall be erected wherever necessary for space on a roof or balcony, but shall not be more than the minimum height required by the Oakland Building Code. b. Location. The space may be located anywhere on the lot. Above-ground-level space may be counted even though it projects beyond a street line. All spaces shall be adjacent to, and not more than four (4) feet above or below the floor level of, the living unit served. c. Size and Shape. An area of contiguous ground-level space shall be of such size and shape that a rectangle inscribed within it shall have no dimension less than ten (10) feet. An area of above-ground-level space shall be of such size and shape that a rectangle inscribed within it shall have no dimension less than five (5) feet. When space is located on a roof, the area occupied by vents or other structures which do not enhance usability of the space shall not be counted toward the above dimension. d. Accessibility. The space shall be accessible to only one (1) living unit by a doorway to a habitable room or hallway. e. Openness. There shall be no obstructions over ground-level space except for devices to enhance its usability and except that not more than fifty percent (50%) of the space may be covered by a private balcony projecting from a higher story. Above-ground-level space shall have at least one (1) exterior side open and unobstructed, except for incidental railings or balustrades, for eight (8) feet above its floor level. Enclosures and landscaping for both usable Group and Private Open Spaces must be consistent with the requirements in the Oak Knoll Design Guidelines. 14. In the D-OK District Residential Zones, Section 2.6 of the Oak Knoll Design Guidelines applies. Parking and loading requirements in the D-OK-4 Zone are the same as in the CN-4 Zone, subject to the exceptions stated in Note 15 below. 15. Locker areas, storage areas, mechanical rooms, and other non-active spaces shall not be located within thirty (30) feet from the front of the principal building except for incidental entrances to such activities elsewhere in the building. Exceptions to this regulation may be permitted by the Planning Director for utilities and trash enclosures that cannot be feasibly placed in other locations of the building. Driveways, garage entrances, or other access to parking and loading facilities may be located in front of the principal building, as regulated by Note 12 to Table 17.33.03 in Planning Code Section 17.33.050.A. "Street" parking is allowed along either the principal street or principal private driveway in front of the principal building. (An example of "street" parking is shown in Figure 1.5 in Chapter 2.3 of the Oak Knoll Design Guidelines.) Parking lots are not allowed in the front of the principal building. 16. The minimum percent transparency for the band between two (2) feet and eight (8) feet in height of any side of a commercial building facing a Principal Drive is forty percent (40%). The minimum percent transparency for the band between two (2) feet and eight (8) feet in height of any side of a commercial building facing a retail plaza is seventy percent (70%). An example of glazing treatment that meets these requirements is illustrated in the figure below: [image omitted; see the official code] 17. The minimum height requirement applies only for new principal buildings and the height is measured from the sidewalk grade to the ground floor ceiling. 18. In the D-OK-1, D-OK-2, and D-OK-3 Zones, the regulations in Sections 17.116.050, 17.116.060 and 17.116.070 for the RH and/or RD Zones apply. In the D-OK-4 Zone, the regulations in Sections 17.116.050, 17.116.070, 17.116.080, 17.116.090, and 17.116.140 for the CN Zone apply. In the D-OK-5 Zone, the regulations in Sections 17.116.050, 17.116.070, 17.116.080, and 17.116.090, and 17.116.130 for "any other zone" apply. In the D-OK-6 and D-OK-7 Zones, the regulations in Sections 17.116.050 through 17.116.100 for the OS Zone apply. 19. See Section 17.103.085 for setback and separation requirements for Vehicular Residential Facilities. B. Height Standards for Sloped, Terraced, or Split Lots. Table 17.101J.04 below prescribes the height standards associated with different sloped, terraced, or split lots. The numbers in the "Additional Regulations" column refer to the regulations listed at the end of the Table. Table 17.101J.04 Height Regulations for all Lots with a Footprint Slope of >20%, Terraced, or Split Regulation | Downslope Lot Height Regulations With a Footprint Slope of: | Upslope Lot Height Regulations With a Footprint Slope of: | Additional Regulations >20% and <40%, and all terraced and split regardless of slope | >40% and <60% | >60% | >20%, terraced and split Maximum Height for Detached Accessory Structures | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 1 Maximum Wall Height Primary Building | 32 ft. | 34 ft. | 36 ft. | 32 ft. | 1, 2 Maximum Wall Height Primary Building with a CUP | 36 ft. | 38 ft. | 40 ft. | 35 ft. | 1 Maximum Pitched Roof Height Primary Building | 36 ft. | 38 ft. | 40 ft. | 35 ft. | 1, 2 Maximum Height Above Edge of Pavement | 18 ft. | 18 ft. | 18 ft. | N/A | 1 Maximum Height Above the Ground Elevation at the Rear Setback Line | N/A | N/A | N/A | 24 ft. | 1 Maximum Height from Finished or Existing Grade (whichever is lower) Within 20' of the Front Property Line | N/A | N/A | N/A | 24 ft. | 1, 3 Additional Regulations for Table 17.101J.04: 1. See Section 17.108.030 for allowed projections above height limits and Section 17.108.020 for increased height limits for civic buildings. 2. On a downslope lot greater than seventeen percent (20%) footprint slope, or that is terraced or split, the rear wall of an attached garage or carport may exceed the wall height and roof height by five (5) feet, but may not exceed eighteen (18) feet above ground elevation at edge of pavement, if the garage or carport conforms with all of the following criteria: a. Maximum width is twenty-two (22) feet and maximum depth is twenty (20) feet; and b. Garage or carport floor is at the same level as the edge of the street pavement resulting from the project at the center point of the driveway entrance or is at a lower level; and c. Maximum height above the garage or carport floor is ten (10) feet for walls to the top of the plate or flat roof, and twelve (12) feet for pitched roofs (see Illustration for Table 17.101J.04, below). 3. The building height is measured from finished or existing grade, whichever is lower. [image omitted; see the official code] C. Additional Development Regulations in the D-OK-1 and D-OK-2 Zones. Table 17.101J.05 below prescribes the standards for garage doors, retaining walls, stoops, and porches in the D-OK-1 and D-OK-2 Zones. The numbers in the "Additional Regulations" column refer to the regulations listed at the end of the Table. Table 17.101J.05 Additional Development Regulations in the D-OK-1 and D-OK-2 Zones Facility | Zones | Additional Regulations D-OK-1 | D-OK-2 Garages Maximum Garage Door Width | 16 ft. | 16 ft. Maximum Garage Door Height | 8 ft. | 8 ft. Minimum Garage Door Recess | 6 in. | 6 in. Retaining Walls Maximum Front Retaining Wall Height | 30 in. | 30 in. | 1 Maximum Side and Rear Retaining Wall Height | — | — Stoops Minimum Landing Depth | 5 ft. | 5 ft. Minimum Landing Width | 6 ft. | 6 ft. Porches Minimum covered area | 30 sq. ft. | 30 sq. ft. Minimum elevation above grade | 8 in. | 8 in. Additional Regulations for Table 17.101J.05: 1. Retaining walls, if used in the front, must be set back a minimum of two (2) feet from the sidewalk.

(Ord. No. 13466, § 2(Exh. A), 11-28-2017; Ord. No. 13666, § 3(Exh. A), 11-16-2021; Ord. No. 13677, § 4(Exh. A), 1-18-2022)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.