§ 17.108.030 — Allowed projections above height limits
Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Planning Code § 17.108.030
Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/8a87af8b-be11-4977-8b62-010bdd2f504b
17.108.030 - Allowed projections above height limits.
The height restrictions prescribed for facilities in the applicable individual zone regulations and development control maps and in Sections 17.108.010 and 17.108.020 may be exceeded in accordance with the following table. However, facilities within required minimum yards and courts shall also be subject to the applicable provisions of Section 17.108.130. Facilities Allowed Above the Prescribed Height | Restrictions on Facility, or Portion Thereof, Above the Prescribed Height Maximum Aggregate Coverage of the Building's Horizontal Area (If on a Building) | Maximum Vertical Projection Above the Prescribed Height | Minimum Horizontal Distance from any Abutting Residentially Zoned Lot Chimneys, ventilators, plumbing vent stacks, water tanks, cooling towers, machinery rooms, and other equipment and appurtenances which are not provided for elsewhere in this Section. (For screening around these, see below.) | Ten (10) percent, minus any percentage covered pursuant to Subsection B. of this Section. | Ten (10) feet, except upon the granting of a conditional use permit pursuant to the conditional use permit procedure in Chapter 17.134. | Fifteen (15) feet, except upon the granting of a conditional use permit; but no restriction if the vertical projection above the prescribed height does not exceed four (4) feet. B. Elevator or stair towers; penthouses, excluding those containing any living unit; stage or scenery lofts in theatres or performance venues; skylights and dormer windows located on principal and accessory Nonresidential Facilities; and rooftop fenced or walled spaces which do not qualify elsewhere in this Section. | Ten (10) percent, minus any percentage covered pursuant to Subsection A. of this Section. | Twelve (12) feet, except upon the granting of a conditional use permit. | Ten (10) feet, except upon the granting of a conditional use permit; but no restriction if the vertical projection above the prescribed height does not exceed four (4) feet. C. Skylights, dormers and gable ends up to fifteen (15) feet in width located on principal and accessory Residential Facilities, except accessory facilities permitted in minimum yards or courts pursuant to Subsection 17.108.130.K. | Ten (10) percent, minus any percentage covered pursuant to Subsection A. of this Section. | Ten (10) feet above maximum wall height for dormers and gable ends, but in all cases, no higher than the maximum roof height; and one (1) foot for skylights, but in all cases, no higher than the maximum height of the roof section on which they are located, except that skylights on a flat roof (slope 1:12 or less) may extend one (1) foot above the roof. | Ten (10) feet, except upon the granting of a conditional use permit; but no restriction if the vertical projection above the prescribed height does not exceed four (4) feet. D. Decorative features such as spires, bell towers, domes, cupolas, obelisks, and monuments. | Ten (10) percent, minus any percentage covered pursuant to Subsection A. or B. of this Section. | Fifteen (15) feet, except upon the granting of a conditional use permit. | Fifteen (15) feet, except upon the granting of a conditional use permit; but no restriction if the vertical projection above the prescribed height does not exceed four (4) feet. E. Fire escapes, catwalks, and open railings required by law. | No restriction. | No restriction. | No restriction. F. Rooftop recreational, observation, seating, outdoor dining, clothesline, and parking facilities, unroofed themselves except for incidental sunshades, wind-screens, and similar devices; rooftop landscaping, other than trees; and unroofed open stairs and rooftop open fencing which do not qualify elsewhere in this Section. | No restriction. | Ten (10) feet, except upon the granting of a conditional use permit. | Fifteen (15) feet, except upon the granting of a conditional use permit; but no restriction if the vertical projection above the prescribed height does not exceed four (4) feet. G. Eaves, awnings, balconies, open stairs, and similar lateral extensions of a building, where the prescribed height is expressed as a ratio to some horizontal setback. | No restriction. | Four (4) feet in the case of Section 17.108.010 and eight (8) feet otherwise. | No restriction. H. Microwave and satellite dishes which are over three (3) feet in diameter and located in any Residential Zone or within one hundred fifty (150) feet from the nearest boundary of any Residential Zone, subject where applicable to the provisions of Section 17.102.240. | Ten (10) percent, minus any percentage covered pursuant to Subsection A. or B. of this Section. | Seven (7) feet, except upon the granting of a conditional use permit. | Ten (10) feet, except upon the granting of a conditional use permit. I. Radio and television masts antennas, other than microwave and satellite dishes. | No restriction. | Fifteen (15) feet, except upon the granting of a conditional use permit. | Five (5) feet, except upon the granting of conditional use permit. J. Trees; flagpoles; weather vanes; microwave and satellite dishes which are three (3) feet or less in diameter; and utility poles and lines. | No restriction. | No restriction. | No restriction. K. Special Signs; and other Signs if flat against the surface of a facility authorized above. | No special restriction, but subject to the regular height and other limitations applicable to Signs. | No special restriction, but subject to the regular height and other limitations applicable to Signs. | No special restriction, but subject to the regular height and other limitations applicable to Signs. Any conditional use permit under Subsection H. of this Section shall be subject to the same use permit criteria as are prescribed in Section 17.102.240.
(Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13172, § 3(Exh. A), 7-2-2013; Ord. No. 13112, § 4(Exh. A), 4-30-2012; Ord. No. 13064, § 2(Exh. A), 3-15-2011; Ord. No. 12999, § 4(Exh. A), 3-16-2010; Ord. 12376 § 3 (part), 2001: prior planning code § 7075)
Ask a question about Oakland law
Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.