For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.19.050 — Property development standards

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Planning Code § 17.19.050

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/56980611-2499-40ff-873a-6686a562e11b

17.19.050 - Property development standards.

A. Zone Specific Standards. Table 17.19.03 below prescribes development standards specific to individual zones. The number designations in the "Additional Regulations" column refer to the regulations listed at the end of the Table. "N/A" designates a standard is not applicable to the specified zone. Table 17.19.03: Property Development Standards Development Standards | Zones | Additional Regulations RU-1 | RU-2 | RU-3 | RU-4 | RU-5 Minimum Lot Dimensions Lot Width mean | 25 ft. | 25 ft. | 25 ft. | 25 ft. | 25 ft. | 1 Frontage | 25 ft. | 25 ft. | 25 ft. | 25 ft. | 25 ft. | 1 Lot area | 2,500 sf. | 2,500 sf. | 4,000 sf. | 4,000 sf. | 4,000 sf. | 1 Maximum Residential Density Permitted density for Regular Dwelling Units | 1 unit per 1,000 sf. of lot area | 1 unit per 750 sf. of lot area | 1 unit per 450 sf. of lot area | See Table 17.19.04 | See Table 17.19.04 | 2 Permitted density for Rooming Units | 1 unit per 500 sf. of lot area | 1 unit per 375 sf. of lot area | 1 unit per 225 sf. of lot area | See Table 17.19.04 | See Table 17.19.04 Permitted density for Efficiency Dwelling Units | 1 unit per 500 sf. of lot area | 1 unit per 375 sf. of lot area | 1 unit per 225 sf. of lot area | See Table 17.19.04 | See Table 17.19.04 Minimum Setbacks for Lots Equal to or Greater than 3,000 Square Feet Minimum front (≤20% street-to-setback gradient) for Residential Facilities | 15 ft. | 10 ft. | 10 ft. | 5 ft. | 0 ft. | 3, 4, 5, 6, 20 Minimum front (>20% street-to-setback gradient) for Residential Facilities | 5 ft. | 5 ft. | 5 ft. | 5 ft. | 5 ft. | 3, 4, 5, 6, 20 Minimum front for Commercial Facilities | 10 ft. | 10 ft. | 5 ft. | 0 ft. | 0 ft. | 3, 20 Minimum interior side | 4 ft. | 4 ft. | 3 ft. | 0 ft. | 0 ft. | 1, 3, 7, 8, 20, 21 Minimum street side | 4 ft. | 4 ft. | 3 ft. | 0 ft. | 0 ft. | 3, 4, 7, 9, 20 Rear (Residential Facilities) | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 1, 3, 7, 10, 11, 20 Rear (Nonresidential Facilities) | 10 ft. | 10 ft. | 10 ft. | 0/10 ft. | 0/10 ft. | 1, 3, 10, 11 Reduced Setbacks for Smaller Lots (Less than 3,000 Square Feet) Minimum interior side | 3 ft. | 3 ft. | 0 ft. | N/A | N/A | 1, 3, 8, 20, 21 Minimum street side | 3 ft. | 3 ft. | N/A | N/A | N/A | 3, 4, 8, 20 Height Regulations Minimum height of ground floor Nonresidential Facilities | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 12 Minimum separation between the grade and ground floor living space | N/A | N/A | N/A | N/A | 2.5 ft. | 13 Maximum height primary building | 45 ft. | 55 ft. | 65 ft. | See Table 17.19.04 | See Table 17.19.04 | 14, 15 Maximum height for accessory structures | 15 ft. | 15 ft. | 15 ft. | See Table 17.19.04 | See Table 17.19.04 Parking Requirements | See Chapter 17.116 for automobile parking and Chapter 17.117 for bicycle parking requirements | 16, 17 Parking and driveway location requirements | No | No | No | Yes | Yes | 18 Minimum Usable Open Space Group usable open space per Regular Dwelling Unit | 75 sf. | 75 sf. | 75 sf. | See Table 17.19.04 | See Table 17.19.04 | 19 Group usable open space per Regular Dwelling Unit when private open space is substituted | 20 sf. | 20 sf. | 20 sf. | See Table 17.19.04 | See Table 17.19.04 | 19 Group usable open space per Rooming Unit | 38 sf. | 38 sf. | 38 sf. | See Table 17.19.04 | See Table 17.19.04 | 19 Group usable open space per Rooming Unit when private open space substituted | 10 sf. | 10 sf. | 10 sf. | See Table 17.19.04 | See Table 17.19.04 | 19 Group usable open space per Efficiency Dwelling Unit | 38 sf. | 38 sf. | 38 sf. | See Table 17.19.04 | See Table 17.19.04 | 12 Group usable open space per Efficiency Dwelling Unit when private open space substituted | 10 sf. | 10 sf. | 10 sf. | See Table 17.19.04 | See Table 17.19.04 | 12 Courtyard Regulations | See Section 17.108.120 Additional Regulations for Table 17.19.03: 1. See Sections 17.106.010 and 17.106.020 for exceptions to lot development standard regulations. 2. See Chapter 17.107 for affordable and senior housing incentives. See Section 17.103.080 and Chapter 17.88 for regulations regarding permitted Accessory Dwelling Units. Also applicable are the provisions of Section 17.102.270 with respect to additional kitchens for a dwelling unit, and the provisions of Section 17.102.300 with respect to dwelling units with five (5) or more bedrooms. 3. See Section 17.108.130 for allowed projections into setbacks. 4. On lots with only Residential Facilities, paved surfaces within required street-fronting yards, and any unimproved rights-of-way of adjacent streets, shall be limited to fifty percent (50%) on interior lots and thirty percent (30%) on corner lots. Exceptions: The maximum percentages of paved surfaces specified in this additional regulation may be exceeded within unimproved rights-of-way in the following cases upon issuance of a private construction of public improvements (P-job) permit or if undertaken directly by the City or by a private contractor under contract to the City: a. Roadway construction or widening; b. Sidewalk construction or widening; and c. Any work pursuant to an approved final map, parcel map or final development plan pursuant to a Planned Unit Development (PUD) permit. For purposes of this additional regulation, an unimproved right-of-way is the portion of a street or alley right-of-way that is not paved. 5. In the RU-1 Zone, if adjacent lots abutting the side lot lines of the subject lot both contain principal Residential Facilities that have front setbacks with a depth of less than the minimum required in this Chapter, the minimum front setback shall be reduced for buildings and other structures on the subject lot up to a line parallel to the front lot line and extended from the most forward projection of the principal Residential Facility on the adjacent lots having the deeper front setback depth, provided such projection is enclosed, has a wall height of at least eight (8) feet, and has a width of at least five (5) feet. In the case of a corner lot, or lot that has one or more vacant parcels next to it, this same principal shall apply if the nearest non-vacant lot to each side of a corner lot, or to each side of a lot that has one or more vacant parcels next to it, have less than the minimum front setback required in this Chapter (see Illustration for Table 17.19.03 [Additional Regulation 5], below). Also, see Section 17.108.130 for allowed projections into setbacks. Illustration for Table 17.19.03 [Additional Regulation 5] *for illustration purposes only [image omitted; see the official code] 6. In all RU Zones, the minimum front setback otherwise required by the applicable individual zone regulations shall be reduced to five (5) feet on any lot with a street-to-setback gradient that exceeds twenty percent (20%), provided, however, that the minimum length of any driveway or parking pad accommodating one or more parking spaces between the front property line and the front building elevation shall be at least eighteen (18) feet (see Illustration for Table 17.19.03 [Additional Regulation 6], below). See Section 17.108.130 for allowed projections into setbacks. Illustration for Table 17.19.03 [Additional Regulation 6] *for illustration purposes only [image omitted; see the official code] 7. See Section 17.108.080 for the required interior side and rear setbacks on a lot containing two (2) or more living units and opposite a legally-required living room window. 8. Wherever an interior side lot line of any lot located in the RU-3, RU-4, or RU-5 Zone abuts an interior side lot line of any lot located in an RH or RD Zone, a side setback of six (6) feet is required. In the case where an interior side lot line of any lot located in the RU-3, RU-4, or RU-5 Zone abuts an interior side lot line in an RM or RU-1 Zone, a side setback of four (4) feet is required (see Illustration for Table 17.19.03 [Additional Regulation 8] below). Illustration for Table 17.19.03 [Additional Regulation 8] *for illustration purposes only [image omitted; see the official code] 9. When the rear yard of a reversed corner lot abuts a key lot that is in an RH, RD, or RM Zone, the required street side yard setback in the rear ten (10) feet of the reversed corner lot is one-half (½) of the minimum front yard required on the key lot, but shall not be required to exceed four (4) feet in width if it would reduce to less than twenty-five (25) feet the buildable width of any corner lot (see Illustration for Table 17.19.03 [Additional Regulation 9], below). Illustration for Table 17.19.03 [Additional Regulation 9] *for illustration purposes only [image omitted; see the official code] 10. Wherever a rear lot line abuts an alley, one-half (½) of the right-of-way width of the alley may be counted toward the required minimum rear setback; provided, however, that the portion of the minimum rear setback actually on the lot itself shall not be so reduced to less than ten (10) feet. Also, see Section 17.108.130 for allowed projections into setbacks. 11. When a rear lot line in the RU-4 or RU-5 Zones is adjacent to an RH, RD, or RM Zone, the required rear setback for both Residential and Nonresidential Facilities is ten (10) feet. When a rear lot line of a lot in these zones is not adjacent to an RH, RD, or RM Zone, the required rear setback is ten (10) feet for Residential Facilities and there is no required setback for Nonresidential Facilities. 12. This height is only required for new principal buildings with ground floor Nonresidential Facilities, and is measured from the sidewalk grade to the second story floor. 13. This regulation only applies to new Residential Facilities and ground floor living space located within fifteen (15) feet of a street frontage. 14. Buildings in the RU Zones shall have a thirty (30) foot maximum height at the setback line associated with any rear or interior side lot line that abut a lot in an RH, RD, or RM Zone; if the principal building on the abutting lot has a height of thirty (30) feet or less, this maximum height shall increase one (1) foot for every foot of distance from this setback line. If the principal building on the abutting lot has a height of greater than thirty (30) feet, the maximum height shall increase two (2) feet for every foot away from the applicable setback line (see Illustration for Table 17.19.03 [Additional Regulation 14], below). Also, see Section 17.108.030 for allowed projections above height limits and Section 17.108.020 for increased height limits in certain situations. Illustration for Table 17.19.03 [Additional Regulation 14] *for illustration purposes only [image omitted; see the official code] 15. In the RU-2 and RU-3 Zone, a building may only exceed forty-five (45) feet in height up to the maximum height if each portion above forty-five (45) feet is set back from the inner line of any minimum side setback, a minimum horizontal distance equal to one (1) foot for each four (4) feet by which it extends above the height of forty-five (45) feet; and set back from the inner line of any minimum rear yard, a minimum horizontal distance equal to one (1) foot for each two (2) feet by which it extends above the height of forty-five (45) feet, provided, however, that such setback from the inner line of the any minimum rear yard need not exceed twenty (20) feet (see Illustration for Table 17.19.03 [Additional Regulation 15], below). Illustration for Table 17.19.03 [Additional Regulation 15] *for illustration purposes only [image omitted; see the official code] 16. Off-street parking and loading shall be provided as prescribed in the off-street parking and loading requirements in Chapter 17.116. Bicycle parking shall be provided as prescribed in the bicycle parking regulations in Chapter 17.117. Also, additional parking standards apply within the S-11 and S-12 Zones, as prescribed in Chapters 17.92 and 17.94. 17. See Section 17.103.080 for additional parking regulations that apply to Accessory Dwelling Units. 18. For the new construction of principal buildings in the RU-4 and RU-5 Zones, access to parking and loading facilities through driveways, garage doors, or other means shall not be from the principal street when alternative access is feasible from another location such as a secondary frontage or an alley. Where this is not feasible, every reasonable effort shall be made to share means of vehicular access with abutting properties. Open parking areas shall not be located between the sidewalk and a principal building. 19. Usable open space is only required on lots with two (2) or more dwelling units, excluding any permitted Accessory Dwelling Units. Each one (1) square foot of private usable open space equals two (2) square feet towards the total usable open space requirement, except that actual group space shall be provided in the minimum amount specified in the table per dwelling unit, excluding any permitted Accessory Dwelling Units. All usable open space shall meet the standards contained in Chapter 17.126. 20. See Section 17.103.085 for setback and separation requirements for Vehicular Residential Facilities. 21. For developments involving the creation of new units on two (2) or more adjoining parcels under the same ownership, there is no minimum interior side setback required between those new units. B. Height, Floor Area Ratio (FAR), Density, and Open Space for the RU-4 and RU-5 Zones Only. Table 17.19.04 below prescribes height, FAR, intensity, and open space standards associated with the Height Areas described in the Zoning Maps. The number designations in the "Additional Regulations" column refer to regulations below the table. "N/A" designates a regulation is not applicable to the specified Height Area. Table 17.19.04 Height, Floor Area Ratio (FAR), Density, and Open Space Regulations for the RU-4 and RU-5 Zones Only Regulation | Height Area | Additional Regulations 35 | 45 | 65 | 95 | 125 Maximum Height | 35 ft. | 45 ft. | 65 ft. | 95 ft. | 125 ft. | 1, 2 Height Minimum Permitted height minimum | N/A | N/A | 35 ft. | 45 ft. | 55 ft. | 3 Conditionally permitted height minimum | N/A | N/A | 25 ft. | 35 ft. | 45 ft. | 3 Maximum Residential Density (square feet of lot area required per dwelling unit) Regular Dwelling Units | 500 sf. | 400 sf. | 300 sf. | 200 sf. | 200 sf. | 4, 5 Rooming Units | 250 sf. | 200 sf. | 150 sf. | 100 sf. | 200 sf. | 4, 5 Efficiency Dwelling Units | 250 sf. | 200 sf. | 150 sf. | 100 sf. | 100 sf. | 4, 5 Maximum Nonresidential FAR | 2.0 | 2.5 | 3.0 | 4.0 | 4.0 | 4, 5 Maximum Number of Stories (not including underground construction) | 3 | 4 | 6 | 8 | 12 Minimum Usable Open Space Group usable open space per Regular Dwelling Unit | 75 sf. | 75 sf. | 75 sf. | 75 sf. | 75 sf. | 6 Group usable open space per Regular Dwelling Unit when private open space substituted | 20 sf. | 20 sf. | 20 sf. | 20 sf. | 20 sf. | 6 Group usable open space per Rooming Unit | 38 sf. | 38 sf. | 38 sf. | 38 sf. | 38 sf. | 6 Group usable open space per Rooming Unit when private open space is substituted | 10 sf. | 10 sf. | 10 sf. | 10 sf. | 10 sf. | 6 Group usable open space per Efficiency Dwelling Unit | 38 sf. | 38 sf. | 38 sf. | 38 sf. | 38 sf. | 6 Group usable open space per Efficiency Dwelling Unit when private open space is substituted | 10 sf. | 10 sf. | 10 sf. | 10 sf. | 10 sf. | 6 Additional Regulations for Table 17.19.04: 1. The maximum height within ten (10) feet of the front property line is either the height limit on the subject lot shown in the above table or the height maximum for the height area of the parcel directly across the principal street, whatever is less (see Illustration for Table 17.19.04 [Additional Regulation 1], below). Illustration for Table 17.19.04 [Additional Regulation 1] *for illustration purposes only [image omitted; see the official code] 2. Buildings in the RU Zones shall have a thirty (30) foot maximum height at the setback line along any rear or interior side lot line that abuts a lot in an RH, RD, or RM Zone; if the principal building on the abutting lot has a height of thirty (30) feet or less, this maximum height may increase one (1) foot for every foot of distance away from this setback line. If the principal building on the abutting lot has a height of greater than thirty (30) feet, the maximum height shall increase two (2) feet for every foot away from the applicable setback line. Also, see Section 17.108.030 for allowed projections above height limits and Section 17.108.020 for increased height limits in certain situations. 3. This minimum height requirement only applies to the new construction of a principal building that is located on parcels adjacent to a street right-of-way that is one hundred (100) feet wide or more. Buildings constructed to accommodate Essential Service, Utility and Vehicular, or Extensive Impact Civic Activities are exempted from the height minimum regulation. The allowed projections into the height limits contained in Section 17.108.030 are not counted towards the height minimum. 4. See Chapter 17.107 for affordable and senior housing incentives. See Section 17.103.080 and Chapter 17.88 for regulations regarding permitted Accessory Dwelling Units. Also applicable are the provisions of Section 17.102.270 with respect to additional kitchens for a primary dwelling unit, and the provisions of Section 17.102.300 with respect to dwelling units with five (5) or more bedrooms. 5. As specified in Section 17.106.030, the total lot area shall be used as the basis for computing both the maximum nonresidential FAR and the maximum residential density for mixed use projects. 6. Usable open space is only required on lots with two (2) or more dwelling units, excluding any permitted Accessory Dwelling Units. Each one (1) square foot of private usable open space equals two (2) square feet towards the total usable open space requirement, except that actual group space shall be provided in the minimum amount specified in the table per dwelling unit, excluding any permitted Accessory Dwelling Units. All usable open space shall meet the standards contained in Chapter 17.126.

(Ord. No. 13805, §§ 2(Exh. A), 3, 7-16-2024; Ord. No. 13763, § 5, 10-3-2023; Ord. No. 13677, § 4(Exh. A), 1-18-2022; Ord. No. 13666, § 3(Exh. A), 11-16-2021; Ord. No. 13518, § 4(Exh. A), 2-5-2019; Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13172, § 3(Exh. A), 7-2-2013; Ord. No. 13090, § 4(Exh. A), 10-4-2011; Ord. No. 13064, § 2(Exh. A), 3-15-2011)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.