§ 8.08.030 — Toilets
Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 8.08.030
Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/7bb2a70b-6545-4160-ac2d-8ce00d307086
8.08.030 - Toilets.
Every food handling establishment, excepting vehicles, shall be provided with adequate and conveniently located toilet facilities on the premises for all employees. A. Where there are five or more persons of different sex, a sufficient number of separate toilets and lavatories shall be provided. No person shall be allowed to use any toilet assigned to persons of the other sex. Every person managing, conducting, or operating any place of business where any beverage containing more than one-half of one percent of alcohol by volume is sold or served for consumption upon the premises shall provide for the use of its patrons separate toilet facilities for each sex. 1. Exception. Food handling establishments with less than thirty-five (35) patrons may be permitted to have one unisex restroom. B. Toilet room floors shall be constructed of cement, wood covered with mastic, or other impervious material, and the angle formed by the floor and wall shall be cove construction, sealed, and so constructed as to be easily cleaned. Surfaces of walls, partitions, doors, fixtures, toilet seats, bowls, and other equipment shall be smooth and nonabsorbent, and all painted surfaces shall be a light color. C. Toilet rooms shall be kept clean and in good repair, well lighted, ventilated to the outside air, and effectively screened against insects. Toilet room doors shall be self-closing and shall not open directly into any room in which food, drinks, or utensils are handled, prepared or stored. D. All sewer drains shall be connected to an approved sanitary sewer and shall be properly trapped and vented. E. In new construction, all toilet rooms shall have floor drains properly trapped and connected to the sanitary sewer. F. Toilet rooms shall be not less than eighteen (18) square feet in area. G. The ceiling height in toilet rooms, measured from the finished floor to the lowest projection from the ceiling, shall be not less than seven feet. H. In new construction the toilet facilities intended for the use of the public shall be so situated that patrons may not pass through the food-preparation rooms.
(Prior code § 4-4.13)
Ask a question about Oakland law
Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
