§ 11.19 — Mid-rise buildings
The Code of the City of Oceanside, California (Supp. No. 50: codified through Ordinance No. 26-OR0412-1, enacted June 17, 2026) · Oceanside City Code § 11.19
Corpus is an independent public-information project, not the official City of Oceanside website. Stable reference: corpuslaw.us/code/c38529af-4d63-4739-9492-138a08e20aa3
Sec. 11.19. - Mid-rise buildings.
In addition to other applicable provisions of the California Fire Code, the City Code, other laws and regulations, and any policies of the fire code official, the provisions of this article apply to every newly constructed mid-rise building of any type construction, or any mid-rise building which undergoes a complete renovation that requires the complete vacancy of the building to complete the renovation. Exception: Vehicle parking garages, towers, steeples and other similar occupancies that are not used for continuous human occupancy. 1. Building access. Building access must be provided and approved by the fire code official. 2. Automatic fire sprinklers and standpipes. a. Every mid-rise building must be protected throughout by an automatic fire sprinkler system that is designed and installed in conformance with the adopted edition of NFPA 13 and in accordance with the following: b. A control valve and a water-flow alarm device must be provided for each floor. Each control valve and flow device must be electronically supervised. c. Every mid-rise building must be provided with a class I standpipe system that is interconnected with the fire sprinkler system. The system must consist of two and one-half-inch (2½") hose valves that must be located in each interior or exterior stairway on every floor level at the main floor landing unless approved by the fire code official. Two (2) Class I hose outlets must also be located on the roof, outside of each stair shaft enclosure that penetrates the roof. The standpipe system must be designed, installed, and tested in accordance with the adopted edition of NFPA 14. 3. Smoke detection. Smoke detectors must be provided in accordance with this section. Smoke detectors shall be connected to an automatic fire alarm system installed in accordance with the adopted edition of NFPA 72. The actuation of any detector required by this section shall operate the emergency voice alarm signaling system and shall operate all equipment necessary to prevent the circulation of smoke through air return and exhaust ductwork. Smoke detectors must be located as follows: a. In every mechanical equipment, electrical, transformer, telephone equipment, unmanned computer equipment, elevator machinery or similar room and in all elevator lobbies. Elevator lobby detectors must be connected to an alarm verification zone or be listed as a releasing device. b. In the main return-air and exhaust-air plenum of each air-conditioning system having a capacity greater than two thousand (2,000) cubic feet per minute. Such devices must be located in a serviceable area downstream of the last duct inlet. c. At each connection to a vertical duct or riser serving two (2) or more stories from a return-air duct or plenum of an air conditioning system. In Group R-1 and R-2 occupancies, a smoke detector is allowed to be used in each return-air riser carrying not more than five thousand (5,000) cubic feet per minute and serving not more than ten (10) air inlet openings. d. In all corridors serving as a means of egress. 4. Fire alarm system. Unless approved by the fire code official, fire alarm control and emergency voice alarm communication panel must be located in either a dedicated fire alarm control panel room with exterior access or in the main lobby. 5. Emergency voice alarm communication system. An emergency voice alarm communication system shall be designed and installed in accordance with NFPA 72 and California Building Code 907.5.2.2 and its subsections, and 11B-215 and its subsections. 6. Locking of stairway doors. All stairway doors that are locked to prohibit access from the interior of the stairway must have the capability of being unlocked simultaneously, without unlatching, upon a signal from the main fire panel area. Upon failure of normal electrical service, or activation of any fire alarm, the locking mechanism must automatically retract to the unlocked position.
(Ord. No. 08-OR0369-1, § 5, 6-11-08; Ord. No. 13-OR0752-1, § 2, 12-4-2013; Ord. No. 16-OR0848-1, § 3, 12-21-2016; Ord. No. 19-OR0757-1, § 2, 12-18-2019; Ord. No. 22-OR0685-1, § 3, 10-5-2022; Ord. No. 25-OR0637-1, § 1, 11-19-2025)
Ask a question about Oceanside law
Corpus searches the Oceanside sections it holds and shows the ones that match, with their citations. Free, no sign-in.