Sec. 4-11.09. Special commercial/industrial building provisions.
(a) Swinging exterior glass doors, wood or metal doors with glass panels, solid wood or metal doors shall be constructed or protected as follows; (1) Wood doors shall be of solid core construction with a minimum thickness of one and three-fourths (1¾) inches. Wood pane doors with panels less than one (1) inch thick shall be covered on the inside with a minimum sixteen (16) U.S. gauge sheet steel, or its equivalent, which is to be attached with screws on minimum six (6) inch centers. Hollow steel doors shall be of a minimum sixteen (16) U.S. gauge and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around any locking device; (2) Except where double cylinder deadbolts are utilized, any glazing in exterior doors or within forty eight (48) inches of any door looking mechanism shall be constructed or protected as follows: (i) Fully tempered glass or rated burglary resistance glazing; (ii) Iron or steel grills of at least one-eighth ( 1/8 ) inch material with a minimum two (2) inch mesh secured on the inside of the glazing may be utilized; or (iii) The glazing shall be covered with iron bars of at least one-half (½) inch round or one (1) inch by one-fourth (¼) inch flat steel material, spaced not more than five (5) inches apart, secured on the inside of the glazing; (iv) Subsections (ii) and (iii) of this section shall not be implemented so as to interfere with the operation of opening windows if such windows are required to be opened by the Building Code. (b) All swinging exterior wood and steel doors shall be equipped as follows: (1) A single or double door shall be equipped with a double cylinder deadbolt. The bolt shall have minimum projection of one (1) inch and be constructed so as to repel cutting tool attack. The deadbolt shall have a embedment of at least three- fourths (¾) inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five (5) pin tumblers, and shall be connected to the inner portion of the lock by connecting screws a least one-fourth (¼) inch in diameter. The provisions of this subsection do not apply where: (i) Panic hardware is required; or (ii) An equivalent device is approved by the enforcing authority; (2) Double doors shall be equipped as follows: (i) When not required for exiting purposes, the inactive leaf of a double door shall be equipped with metal flush bolts having a minimum embedment of five-eighths ( 5/8 ) inch into the head and threshold of the door frame; (ii) Double doors shall have an astragal constructed of steel a minimum of.125 inches thick which will cover the opening between the door. The astragal shall be a minimum of two (2) inches wide, and extend a minimum of one (1) inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with nonremovable bolts spaced apart on not more than ten (10) inch centers. (c) Aluminum frame swinging doors shall be equipped as follows: (1) The jamb on all aluminum frame swinging doors shall be so constructed or protected to withstand one thousand six hundred (1,600) pounds of pressure in both a vertical distance of three (3) inches and a horizontal distance of one (1) inch each side of the strike, so as to prevent violations of the strike; (2) Except when panic hardware is required, a single or double door shall be equipped with a double cylinder deadbolt with a bolt projection exceeding one (1) inch, or a hook shaped or expanding dog bolt that engages the strike sufficiently to prevent spreading. The deadbolt lock shall have a minimum of five (5) pin tumblers and a cylinder guard. (d) Panic hardware, whenever required by the Uniform Building Code or California Code of Regulation, Title 19, shall be installed as follows: (1) Panic hardware shall contain a minimum of two (2) locking points on each door; or (2) On single doors, panic hardware may have one (1) locking point which is not to be located at either the top or bottom of the door frame. The door shall have an astragal constructed of steel 0.125 inches thick which shall be attached with nonremovable bolts to the outside of the door. The astragal shall extend a minimum of six (6) inches vertically above and below the latch of the panic hardware. The astragal shall be a minimum of two (2) inches wide and extend a minimum of one (1) inch beyond the edge of the door to which it is attached; (3) Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point which will close the opening between them, but not interfere with the operation of either door. (e) Horizontal sliding doors shall be of the inside slider type and equipped with a metal guide track at top and bottom and a cylinder lock and/or padlock with a hardened steel shackle which locks at both heel and toe, and a minimum five (5) pin tumbler operation with a nonremovable key when in an unlocked position. The bottom track shall be so designed that the door cannot be lifted from the track when the door is in a locked position. (f) In office buildings (multiple occupancy), all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors. (g) Windows shall be deemed accessible if less than twelve (12) feet above ground. Accessible windows and all exterior transoms having a pane exceeding ninety six (96) square inches in an area with the smallest dimension exceeding six (6) inches and not visible from a public or private vehicular access- way shall be protected in the following manner: (1) Fully tempered glass or burglary resistant glazing; or (2) The following window barriers may be used but shall be secured with nonremovable bolts: (i) Inside or outside iron bars of at least one-half (½) inch round or one (1) inch by one- quarter (¼) inch flat steel material, spaced not more than five (5) inches apart and securely fastened; or (ii) Inside or outside iron or steel grills of at least one-eighth ( 1/8 ) inch material with not more than a two (2) inch mesh and securely fastened; (3) If a side or rear window is of the type that can be opened, it shall, where applicable, be secured on the inside with either a slide bar, bolt, crossbar, auxiliary locking device, or padlock with hardened steel shackle, a minimum four (4) pin tumbler operation; (4) The protective bars or grills shall not interfere with the operation of opening windows if such windows are required to be opened by the Uniform Building Code. (h) Roof openings shall be equipped as follows: (1) All skylights on the roof of any building or premises used for business purposes shall be provided with: (i) Rated burglary resistant glazing; (ii) Iron bars of at least one-half (½) inch round or one (1) inch by one-fourth (¼) inch flat steel material under the skylight and securely fastened; or (iii) A steel grill of at least one-eighth ( 1/8 ) inch material with a maximum two (2) inch mesh under the skylight and securely fastened. Smoke and heat vents must have a minimum of one (1) inch mesh per Fire Department requirements; (2) All hatchway openings on the roof of any building or premises used for business purposes shall be secured as follows: (i) If the hatchway is of wooden material, it shall be covered on the inside with at least sixteen (16) U.S. gauge sheet metal, or its equivalent, attached with screws; (ii) The hatchway shall be secured from the inside with a slide bar or slide bolts; (iii) Outside hinges on all hatchway openings shall be provided with nonremovable pins when using pin-type hinges; (3) All air duct or air vent openings exceeding ninety six (96) square inches on the roof or exterior walls of any building or premises used for business purposes shall be secured by covering the same with either of the following: (i) Iron bars of at least one-half (½) inch round or one (1) inch by one-fourth (¼) inch flat steel materials spaced no more than five (5) inches apart and securely fastened; or (ii) Iron or steel grills of at least one-eighth ( 1/8 ) inch material with a maximum two (2) inch mesh and securely fastened; (iii) If the barrier is on the outside, it shall be secured with bolts which are nonremovable from the exterior; (iv) The above (i) and (ii) must not interfere with venting requirements creating a potentially hazardous condition to health and safety or conflict with the provisions of the Uniform Building Code or California Code of Regulations, Title 19. (i) Permanently affixed ladders leading to roofs shall be fully enclosed with sheet metal to a height of ten (10) feet. This covering shall be locked against the ladder with a case hardened hasp, secured with nonremovable screws or bolts. Hinges on the cover will be provided with nonremovable pins when using pin-type hinges. If a padlock is used, it shall have a hardened steel shackle, locking at both heel and toe, and a minimum five (5) pin tumbler operation with nonremovable key when in an unlocked position. (j) The following standards shall apply to lighting, address identification and parking areas: (1) Street address numbers shall adhere to standards set forth in § 9-1.3280 of the Zoning Ordinance. Numbers and the backgrounds shall be of contrasting color and shall be reflective for nighttime visibility; (2) Rooftop address numbers shall be installed on all new construction or development of commercial/industrial buildings for which an alarm permit or other discretionary permit is requested. The rooftop numbers shall be a minimum of three (3) feet in length and one (1) foot in width and shall be painted on the rooftops in reflective white paint on a flat black painted background, away from any rooftop obstacles. The rooftop numbers shall be placed on the rooftops in a parallel direction to the displayed streetside numbers. Such rooftop numbers shall be screened from public view and visible only from aircraft. The rooftops of those buildings with multiple suites shall also have the suite number or letters painted, to the same specifications set forth above, on the rooftop over the primary entrance to that suite as follows: | Address | A | B | C | D This requirement to include suite identification shall not apply where in the opinion of the Chief of Police it is not feasible to do. In determining where suite identification is feasible, the Chief shall consider the size of the building, space on the rooftop and location of suites. (3) Rear addressing, including street name, shall be installed on any multiple building development. Address numbering shall adhere to standards set forth in § 9-1.3280 of the Zoning Ordinance; (4) All parking, common, and storage areas must have maintained one (1) footcandle power. These areas are to be lighted from sunset to sunrise by photo censored cell; (5) Lighting in exterior areas shall be in vandalism resistant fixtures; (6) The developer shall submit certified exterior lighting plans showing luminaire throw pattern and cut sheets of luminaires to be used prior to building permits being issued; (7) Interior night lighting shall be constructed and maintained in those areas that are visible from the street (ground floor level only). (k) Elevators. (1) Passenger elevators, the interiors of which are not completely visible when the car door is open, shall have mirrors so placed as to make visible the whole of the elevator interior to prospective passengers outside the elevator; mirrors shall be framed and mounted to minimize the possibility of their accidentally falling or shattering; (2) Elevator emergency stop button shall be so installed and connected as to activate the elevator alarm. (l) Security fencing. (1) If security fencing is installed, the Police Department will be provided access by the Knox submaster system. If gates are not electrically operated, a “KNOX” padlock may be substituted for electrically operated override systems; (2) If wrought iron fencing is used, it shall be six (6) feet high, open ended, and pickets shall be four (4) inches on center. If block wall fencing is used, it shall be six (6) feet high with security shrubbery and anti-graffiti measures (i.e., vines and the like) will be used; (3) If barbed wire or similar material is used, it shall be at least six (6) feet above the ground. (m) Helicopter pad. Any building that is required by City Fire Ordinance to maintain a helicopter pad must allow access to Ontario Police Department helicopters as needed. (n) Public Safety 800 MHZ Radio Amplification System. (1) Except as otherwise provided in this section, no person shall construct or develop any commercial or industrial building or structure or any part thereof or cause the same to be done which fails to support adequate radio coverage for City emergency service workers, including, but not limited to, firefighters and police officers. For purposes of this section, adequate radio coverage shall include all of the following: (i) the frequency range which must be supported shall be 806MHZ to 824 MHZ and 850 MHZ to 869 MHZ, and the frequency range which must be rejected shall be 824 MHZ to 849 MHZ and 859 MHZ to 894 MHZ; (ii) a minimum signal strength of one (1) microvolt available at the City of Ontario Communications Systems when transmitted from eighty five percent (85%) of the area of each floor of the building; (iii) the frequency range which must be supported shall be 806 MHZ to 824 MHZ and 850 MHZ to 869 MHZ, and the frequency range which must be rejected shall be 824 MHZ to 849 MHZ and 869 MHZ to 894 MHZ; (iv) a ninety percent (90%) reliability factor. (2) Testing procedures. (i) Initial tests will be performed by the City of Ontario employees in accordance with this section. A Certificate of Occupancy shall not be issued for any structure if the building fails to comply with this section. (ii) Annual tests will be conducted by the Ontario Fire Department in conjunction with inspection procedures. (iii) In addition to the initial and annual tests, City Police and Fire Personnel, after obtaining consent from the owner or his representative, or absent such consent, after obtaining other lawful authority, shall have the right to enter onto the property to conduct field testing to be certain the required level of radio coverage is present. (iv) If at any time during normal operation within the structure by emergency personnel, it is discovered there exists a problem with radio transmission or reception, a test shall be initiated to determine compliance with established signal strength and coverage. Failure to comply with this process shall result in revocation of license to conduct said business. (3) Correction of radio coverage deficiency. Should a property fail the testing by the City, the deficiency shall be corrected as follows: (i) The property owner or other person responsible for the property shall have thirty (30) days to correct the radio deficiency. (ii) Failure to correct the deficiency within thirty (30) days shall result in suspension of license to conduct said business(s) on the property until the deficiency is corrected. (4) Amplification systems allowed. Buildings and structures which cannot support the required level of radio coverage shall be equipped with any of the following in order to achieve the required adequate radio coverage: (i) a radiating cable system; or (ii) an internal multiple antenna system with FCC type-accepted bidirectional 800 MHZ amplifiers. If any part of the installed system or systems contains an electrically powered component, the system shall be capable of operating on an independent battery and/or generator system for a period of at least twelve (12) hours without external power input. The battery system shall automatically charge in the presence of an external power input. Any person who constructs or develops a commercial or industrial building or structure shall provide two (2) inch raceways in the walls into which the cable could be laid. Such raceways shall include an opening in the roof which allows for placement of an exterior antenna and access to each floor. (5) Exemptions. This section shall not apply to the following buildings provided they do not make use of any metal construction or any underground storage or parking areas: (i) buildings permitted in R1 and R2 zones; (ii) any building constructed of wood frame; (iii) any building thirty (30) feet high or less. For purposes of this section, parking structures are included in the definition of “all parts of a building” but elevators may be excluded. (§ 1, Ord. 2482, eff. October 4, 1990, as amended by § 2, Ord. 2658, eff. April 16, 1998, § 1, Ord. 2666, eff. July 2, 1998, Ord. 2731, eff. April 5, 2001)
Ask a question about Ontario law
Corpus searches the Ontario sections it holds and shows the ones that match, with their citations. Free, no sign-in.