Sec. 8-15.505. Floors.

(a) Vent openings to underfloor areas of wood framed floors shall be provided with acoustic vent baffles that meet noise reduction levels shown in Table 15-A. Vent baffles shall be fitted with one-fourth (¼) inch mesh screen. Table 15-A Octave Band Center Frequency, Hz | Sound Transmission Loss, dB Table 15-A Octave Band Center Frequency, Hz | Sound Transmission Loss, dB 125 | 4 250 | 5 500 | 6 1,000 | 9 2,000 | 10 4,000 | 12 (b) Underfloor access doors shall be nonvented plywood or other weatherproof material. (§ 2, Ord. 2616, eff. June 20, 1996)