§ 17.12.070 — Fences and Walls
Municipal Code, City of Orange, California (through Ord. No. 01-26 adopted January 27, 2026) · Orange Municipal Code § 17.12.070
Corpus is an independent public-information project, not the official City of Orange website. Stable reference: corpuslaw.us/code/9d16ac5f-b300-419a-ab42-8e797acf93d4
§ 17.12.070: Fences and Walls.
Fences and walls shall be permitted in all zoning districts subject to the following regulations: A. All Zoning Districts. 1. Location. a. All perimeter fences and walls shall be constructed on the property line unless a different location is permitted by the Community Development Director, or unless otherwise specified by applicable design standards. b. No parallel fence or wall shall be constructed less than five feet from an existing fence or wall, unless approved by the Community Development Director. 2. Corner cut off shall be required per Section 17.14.150. 3. Materials are allowed per Table 17.12.070(A)(3). Table 17.12.070(A)(3) Material | R and MH Zones | OP and C Zones | M and SG Zones | MU Zones | PI, A1, RO, and SH Zones Wood, masonry, vinyl, composite | P1 | P1 | P1 | P1 | P1 Decorative metals | P1,2 | P1,2 | P1,2 | P1,2 | P1,2 Chain link | -3 | -3 | P1, 3 | -3 | P1 Coated vinyl mini-mesh chain link | P1 | P1 | P1 | - | P1 Barbed wire, concertina wire | -4 | - | P1,6 | - | P1,6 Electrified fences | P5 | - | P1,6 | - | P1,6 P = Permitted - = Not permitted NOTES: (1) | If within a historically or architecturally significant district, additional material restrictions may apply. Refer to the corresponding design standards for the appropriate district. (2) | Sheet metal and corrugated steel are permitted with Community Development Director approval when integrated into the overall design and architecture of the project. (3) | Chain link fencing shall not be erected in any required yard setback facing a public or private street. Exception: Chain link fencing may be used for security purposes for public utility structures and for temporary fencing needs (construction sites, special events, vacant lots, etc.) and screening shall be required subject to the determination of the Community Development Director. (4) | Exception for public utility structures. (5) | Electrified fences are not allowed on any lots less than 20,000 square feet or as perimeter fencing. A lot 20,000 square feet or more may have electrified fences inside an enclosing perimeter fence. (6) | Materials not allowed as perimeter fencing may be allowed as interior fencing, subject to Community Development Director approval. 4. Greater Height of Fences and Walls in Side and Rear Yards. a. A greater height than the height limit established, up to a maximum of two additional feet, may be considered by the Zoning Administrator through an administrative adjustment. Refer to Section 17.10.050. b. A greater height than the height limit established may be considered by the Planning Commission through a variance. Refer to Section 17.10.040(C). B. Residential. 1. Side and Rear Yards—Standard Lot. Fence and wall heights shall be measured from adjacent grade to the top of the fence or wall structure. Any items connected to the fence or wall, such as, but not limited to, decorative latticework, privacy toppers, and screens, shall be counted towards the overall height of the fence or wall, as referenced in Figure 17.12.070(B)(1). Fences and walls located in the side and rear yards of standard lots shall be limited in height as follows: a. Six feet, as measured from the highest elevation of land contiguous to the fence, and 10 feet as measured from the lowest elevation contiguous to the fence. b. For properties within 300 feet of freeways or railroads and build out Noise Contours, as defined by the Orange General Plan Noise Element – Noise Contours and subsequent noise modifications as defined by adopted noise studies, sound wall height may be up to eight feet as measured from the highest elevation of land contiguous to the wall and 10 feet as measured from the lowest elevation contiguous to the wall. c. For properties abutting a nonresidential zoning district the height may be up to eight feet as measured from the highest elevation of land contiguous to the fence or wall, and 10 feet as measured from the lowest elevation contiguous to the fence or wall. Figure 17.12.070(B)(1) [image] 2. Front Yard—Standard Lot. In the required front yard area, the height shall be limited to three and one-half feet. 3. Corner, Reverse Corner and Key Lots. For corner, reverse corner, and key lots, fence and wall heights shall be limited as indicated on Figure 17.12.070(B)(3). Figure 17.12.070(B)(3) [image] 4. Tract Fencing. Fences and walls adjacent to public streets, surrounding residential tracts, shall be constructed by the developer and maintained in a safe structural condition by the homeowner's association, or by each individual home owner on whose property the fence or wall is located if no homeowner's association exists. Periodic repair or maintenance of any section of the fence or wall shall be done in a manner that matches the original design and appearance. The intent of this section is to ensure that the fence or wall maintains a consistent appearance around the entire perimeter of the tract, and is not intended to preclude repainting, replastering or such other maintenance as may be required, provided such treatment is applied to the entire contiguous fence or wall, including fence or wall area beyond the individual property. C. Mobile Home. 1. Perimeter Screening. In order to provide a buffer between mobile home parks and abutting uses, an eight-foot high solid, masonry wall shall be installed and maintained along, but no closer than, 10 feet from the ultimate or future right-of-way from any public street and three feet from any mobile home. Where there is a difference in elevation on opposite sides of such screen, the height shall be measured from the highest grade level. 2. For properties within 300 feet of freeways or railroads and build out noise contours, as defined by the Orange General Plan Noise Element – Noise Contours and subsequent noise modifications as defined by adopted noise studies, sound wall height may be up to 10 feet as measured from the highest elevation of land contiguous to the wall and 12 feet as measured from the lowest elevation contiguous to the wall. D. Commercial. 1. Division Wall Required. a. A masonry division wall at least eight feet in height as measured from the highest elevation of land contiguous to the fence, and not greater than 10 feet in height as measured from the lowest elevation contiguous to the fence, shall be constructed on all property lines adjacent to any residential district, except in a street-facing, front, side, or rear yard setback where the wall shall be limited to 42 inches in height. Division wall height less than eight feet or taller than 10 feet as measured from the lowest elevation contiguous to the wall may be considered by the Community Development Director. b. Properties with an outdoor use component that is integral to the principal use of the subject site and located adjacent to any freeway or railroad may have fences and walls taller than the limits set forth herein. Refer to Section 17.12.070(A)(4). c. Commercial properties not in conformance with Section 17.12.070 shall comply at the time of any substantial improvement, as defined by Section 17.04.038. 2. Other Fences and Walls. Fences and walls are permitted in any yard area subject to the following regulations: a. Front Yard. In the required front yard area, the height shall be limited to 42 inches. b. Side Yard. In required street side yard areas, the height shall be limited to 42 inches. c. All Other Areas. In all other areas, the height shall be limited to six feet as measured from the highest elevation of land contiguous to the fence or wall, and 10 feet as measured from the lowest elevation contiguous to the fence or wall. 3. Location. All perimeter fences and walls shall be constructed on the property line unless a different location is permitted by the Community Development Director, or unless otherwise specified by applicable design standards. No parallel fence or wall shall be constructed less than five feet from an existing fence or wall, unless approved by the Community Development Director. E. Industrial. 1. Division Wall Required. a. A masonry division wall at least eight feet in height as measured from the highest elevation of land contiguous to the fence, and not greater than 10 feet in height as measured from the lowest elevation contiguous to the fence, shall be constructed on all property lines adjacent to any residential district, except in a street-facing, front, side, or rear yard setback where the wall shall be limited to 42 inches in height. Division wall height taller than 10 feet as measured from the lowest elevation contiguous to the wall may be considered by the Community Development Director. b. In industrial properties where a stationary noise source produces exterior noise greater than 65 dBA, the division wall shall be at least eight feet as measured from the highest elevation of land contiguous to the fence, and 12 feet as measured from the lowest elevation contiguous to the fence. c. Industrial properties not in conformance with Section 17.12.070 shall comply at the time of any substantial improvement, as defined by Section 17.04.038. 2. Other Fences and Walls. Fences and walls are permitted in any yard area subject to the following height regulations: a. Front Yard. In the required front yard area: i. Solid fences and walls are limited to 42 inches in height. ii. Along non-arterial streets, open fences may be up to six feet in height. b. All Other Areas. In all other areas, fences and walls may exceed eight feet in height provided that a site assessment is submitted for review by the Community Development Director. The assessment must address the following as a minimum: i. A discussion evaluating the operational capacity of the existing land use and its impacts on the immediate vicinity. ii. An analysis demonstrating that the additional height does not negatively impact the surrounding property or public streets. iii. Scaled and dimensioned plans providing an adequate basis of evaluation. iv. A concluding statement containing evidence that the proposed fence or wall will benefit the community and will not adversely impact any residential areas or any public streets. The Community Development Director shall approve such fences and walls if it is found that the applicant's site assessment contains the requisite evidence and analysis. 3. Location. All perimeter fences and walls shall be constructed on the property line unless a different location is permitted by the Community Development Director, or unless otherwise specified by applicable design standards. No parallel fence or wall shall be constructed less than five feet from an existing fence or wall, unless approved by the Community Development Director. F. Mixed Use. 1. Division Wall Required. a. A masonry division wall up to eight feet in height as measured from the highest elevation of land contiguous to the fence shall be constructed on all property lines adjacent to any single-family residential district, except in a street-facing, front, side, or rear yard setback where the wall shall be limited to 42 inches in height. In the OTMU-15S zone, a wood fence may also provide separation between properties. b. Pedestrian access points are encouraged and may be allowed subject to approval of the Community Development Director. c. Properties not in conformance with Section 17.12.070 shall comply at the time of any substantial improvement, as defined by Section 17.04.038. 2. Other Fences and Walls. Fences and walls are permitted in any yard area subject to the following: a. Front Yard. In the front yard area, the height shall be limited to 42 inches. b. Street Side Yard. In street side yard areas, the height shall be limited to 42 inches. c. All Other Areas. In all other areas, the height shall be limited to six feet, as measured from the side of the fence or wall with the highest grade. d. For properties within 300 feet of freeways, railroads and build out noise contours, as defined by the Orange General Plan Noise Element – Noise Contours and subsequent noise modifications as defined by adopted noise studies, sound wall height may be up to eight feet as measured from the highest elevation of land contiguous to the wall and 10 feet as measured from the lowest elevation contiguous to the wall, except in a street-facing, front, side, or rear yard setback, where the wall shall be limited to 42 inches in height. 3. Location. All perimeter fences and walls shall be constructed on the property line unless a different location is permitted by the Community Development Director, or unless otherwise specified by applicable design standards. No parallel fence or wall shall be constructed less than five feet from an existing fence or wall, unless approved by the Community Development Director. G. Public Institutions. 1. Division Wall Required. A masonry division wall shall be constructed on all property lines adjacent to any residential district, except in a street-facing, front, side, or rear yard setback where the wall shall be limited to 42 inches in height. a. A masonry division wall at least eight feet in height as measured from the highest elevation of land contiguous to the fence shall be constructed on all property lines adjacent to any residential district, except in a street-facing, front, side, or rear yard setback where the wall shall be limited to 42 inches in height. b. In properties where a stationary noise source produces exterior noise greater than 65 dBA, the division wall shall be at least eight feet as measured from the highest elevation of land contiguous to the fence, and 12 feet as measured from the lowest elevation contiguous to the fence. c. Properties which are not in conformance with Section 17.12.070 shall comply at the time of any substantial improvement, as defined by Section 17.04.038 2. Other Fences and Walls. Fences and walls are permitted in any yard area subject to the following height regulations: a. Front Yard. In the required front yard area, the height shall be limited to 42 inches. b. All Other Areas. In all other areas, fences and walls may exceed six feet in height with a determination by the Community Development Director. 3. Location. All perimeter fences and walls shall be constructed on the property line unless a different location is permitted by the Community Development Director, or unless otherwise specified by applicable design standards. No parallel fence or wall shall be constructed less than five feet from an existing fence or wall, unless approved by the Community Development Director. H. Agriculture, Open Space, and Slope and Hazard. Fences and walls shall be permitted in accordance to commercial regulations contained in Section 17.12.070(C). I. Sand and Gravel. 1. Perimeter Screening. In order to provide a buffer between sand and gravel operations and abutting uses, an eight-foot high solid, masonry wall shall be installed and maintained along, but no closer than, 10 feet from the ultimate or future right-of-way from any public street. Where there is a difference in elevation on opposite sides of such screen, the height shall be measured from the highest grade level. 2. A required screen shall be installed prior to commencement of operations. 3. Fences and walls not conforming to Section 17.12.070(I) are subject to review and approval by the Community Development Director.
( Ord. 19-21 , 2022 ; Ord. 09-22 , 2022 )
Ask a question about Orange law
Corpus searches the Orange sections it holds and shows the ones that match, with their citations. Free, no sign-in.