For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.16.060 — Development Standards

Municipal Code, City of Orange, California (through Ord. No. 01-26 adopted January 27, 2026) · Orange Municipal Code § 17.16.060

Corpus is an independent public-information project, not the official City of Orange website. Stable reference: corpuslaw.us/code/274107a5-228d-4fa9-b8eb-e0650cbc7433

§ 17.16.060: Development Standards.

This section establishes minimum development standards for PUDs. The reviewing body may require more stringent standards to ensure compatibility with surrounding uses, quality of life for future residents and protection of public health, safety, and general welfare. A. Density. The total number of dwelling units permitted shall not exceed the number allowed by the General Plan. In establishing the density, the reviewing body shall consider compatibility with surrounding land uses and densities on adjacent parcels. B. Building Height. The underlying zone district shall govern the maximum permitted building heights for all structures within a PUD. C. Building Separation. Distance between dwellings are required in order to provide adequate light and air and privacy. The provisions outlined in Table 17.16.060 shall apply, as well as specific provisions found in building and fire codes. Architectural features such as chimneys and eaves may encroach into the required separation area by no more than two feet. D. Setback from Public Right-of-Way. All structures (including walls or fences exceeding 42 inches in height) shall be set back a minimum of 20 feet from a public right-of-way. The required setback area shall be landscaped. E. Project Area Boundary Setback. All habitable structures shall be set back a minimum of 10 feet from any project boundary not abutting a street. Buffer of trees or hedges shall be provided as appropriate to ensure compatibility with adjacent uses. F. Interior Street Setbacks. All structures shall be set back a minimum of 10 feet from any interior street. Garage door openings shall be set back a minimum of 20 feet from any interior street, unless one additional parking space is provided for all units containing garages with driveways less than 20 feet in length. Such space must be conveniently located to the units. Table 17.16.060 REQUIRED DISTANCES BETWEEN BUILDINGS Minimum Required Distance Between Principal Structures on the Same Lot (a) Number of Structures | Front/Any Other Building Wall | All Other Configurations | Minimum Distance Between Principal and Accessory Structure One | N/A | N/A | 6 feet Two to Four | 15 feet | 8 feet | 6 feet Five or More | 25 feet from view allowing windows in any adjacent structure. 15 feet minimum between solid facing walls, or when windows are located on only one facing wall. | 6 feet NOTE: (a) | For obliquely aligned buildings, the required distance between two principal structures may be decreased by up to five feet if the distance at the opposite corner is increased by an equal or greater distance. G. Landscaping. Landscaping shall be provided as required by the City's Landscape Standards and Specifications. H. Open Space/Recreation. 1. Usable open space shall be provided as set forth in Table 17.14.070 of this title. Usable open space shall not include any portion of off-street parking space, driveways, turnaround areas, required setback area from public right-of-way. a. Private open space shall be provided in the form of a fenced or screened yard or patio, a deck, or a balcony. In order to count toward the open space requirement, a yard area, or uncovered patio or deck shall have a minimum width and length of 10 feet, the minimum dimension of a balcony (both width and depth) shall be seven feet. i. For PUDs containing up to six units per acre, a minimum of 450 square feet per unit shall be provided. ii. For PUDs containing seven or more units per acre, a minimum of 100 square feet per unit shall be provided. b. Common usable open space areas shall conform to the requirements set forth in Table 17.14.070 and Section 17.14.110(B) of this title. 2. Recreation Facilities/Open Space Amenities. a. Within each PUD, one common recreational or open space amenity shall be provided for each 25 units or fraction thereof. A mix of recreational amenities shall be provided for PUDs exceeding 25 units. b. The following listed amenities satisfy the recreational facilities requirement recognizing that certain facilities serve more people, have a wider interest or appeal and/or occupy more land area than others, specified items may be counted as two amenities: i. Clubhouse (two); ii. Swimming pool (two); iii. Tennis court (one per court); iv. Basketball court (one per court); v. Racquetball court (one per court); vi. Weightlifting facility; vii. Children's playground equipment; viii. Sauna; ix. Jacuzzi; x. Day care facility; xi. Lake or water feature (excluding water fountain); xii. Other recreational amenity/facility deemed adequate by the Community Development Director. 3. Pedestrian Paths. There shall be a system of pedestrian pathways connecting all dwelling units or dwelling groups to common usable open space areas. I. Private Streets. Private streets shall be permitted when a home owners' association is established to maintain them. Streets shall be constructed to standards and specifications acceptable to the Director of Public Works. J. Access. Access to each residential unit shall be provided by either a public right-of-way or private vehicular way. Residential units shall not have individual vehicular access onto arterial highways. Access roadways shall adequately provide for fire fighting apparatus and refuse collection. K. Parking Regulations. Off-street parking shall be provided as set forth in Chapter 17.34 of this title.

( Prior code 17.66.090, 17.82.030 ; Ord. 44-73 ; Ord. 19-79 ; Ord. 20-82 ; Ord. 12-95 )

Ask a question about Orange law

Corpus searches the Orange sections it holds and shows the ones that match, with their citations. Free, no sign-in.