§ 15.28.120 — Standards of construction
Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 15.28.120
Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/c04f3e52-6ff7-418d-b5b2-f42a51c8f9fe
§ 15.28.120: Standards of construction.
In all areas of special flood hazards the following standards are required to be met to the satisfaction of the Floodplain Administrator: (A) Anchoring. (1) All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (2) All manufactured homes shall meet the anchoring standards of PMC § 15.28.150. (B) Construction Materials and Methods. (1) All new construction and substantial improvements, including manufactured homes, shall be constructed with materials and utility equipment resistant to flood damage below the base flood elevation; (2) All new construction and substantial improvements, including manufactured homes, shall be constructed using methods and practices that minimize flood damage; (3) All new construction and substantial improvements, including manufactured homes, shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (4) All new construction and substantial improvements, including manufactured homes, within Zones AH or AO shall be required to have adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. (C) Elevation and Floodproofing. (1) In an AO Zone, new residential construction and substantial improvement, including manufactured homes, of any residential lowest floor, including basement, elevated to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified; (2) In an A and AE Zone, new residential construction and substantial improvement, including manufactured homes, of any residential structure shall have the lowest floor, including basement, elevated to or above the base flood elevation; (3) In all other special flood hazard area zones, new residential construction and substantial improvement, including manufactured homes, of any residential structure shall have the lowest floor, including basement, elevated to or above the base flood elevation; (4) Upon completion of the residential structure, the elevation of the lowest floor, including basement, shall be verified by a registered professional engineer or surveyor, and verified by the City Building Inspector to be properly elevated. Such certification or verification shall be provided to the Floodplain Administrator; (5) Nonresidential construction, new or substantial improvement, shall either be elevated in conformance with subsection (C)(1), (2) or (3) of this section or together with attendant utility and sanitary facilities: (a) Be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water, (b) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy, and (c) Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certifications shall be provided to the Floodplain Administrator; (6) All new construction and substantial improvements, that have fully enclosed areas below the lowest floor (excluding basements) and are usable solely for parking of vehicles, building access or storage that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: (a) Have a minimum of two openings on different sides having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices; provided, that they permit the automatic entry and exit of floodwaters, or (b) Be certified by a registered professional engineer or architect to comply with a local floodproofing standard approved by the Federal Insurance Administration; (7) Manufactured homes shall also meet the standards in PMC § 15.28.150. (D) Garages and Low-Cost Accessory Structures. (1) Attached Garages. (a) A garage attached to a residential structure, constructed with the garage floor slab below the BFE, must be designed to allow for the automatic entry of floodwaters. Areas of the garage below the BFE must be constructed with flood resistant materials. (b) A garage attached to a nonresidential structure must meet the above requirements or be dry floodproofed. For guidance on below grade parking areas, see FEMA Technical Bulletin TB-6, as it may be amended from time to time. (2) Detached Garages and Accessory Structures. (a) "Accessory structures" used solely for parking (two-car detached garages or smaller) or limited storage (small, low-cost sheds), as defined in PMC § 15.28.010, may be constructed such that its floor is below the base flood elevation (BFE), provided the structure is designed and constructed in accordance with the following requirements: (i) Use of the accessory structure must be limited to parking or limited storage; (ii) The portions of the accessory structure located below the BFE must be built using flood-resistant materials; (iii) The accessory structure must be adequately anchored to prevent flotation, collapse and lateral movement; (iv) Any mechanical and utility equipment in the accessory structure must be elevated or floodproofed to or above the BFE; (v) The accessory structure must comply with floodplain encroachment provisions in PMC § 15.28.160; and (vi) The accessory structure must be designed to allow for the automatic entry of flood waters in accordance with subsection (C)(6) of this section. (b) Detached garages and accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in this section.
( Ord. 1563 § 1 (Exh. A), 2021 )
Ask a question about Palmdale law
Corpus searches the Palmdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.