§ 17.100.090: Development standards.
(A) Single-Family Residential. (1) Side Setback. (a) Maintenance and revegetation of downslopes to property lines shall be ensured through use of slopes no greater than a 3:1 ratio, which may be used in combination with retaining walls. Where necessary, additional lot width may be required to meet this requirement. (b) A minimum five-foot-wide flat surface shall be provided between any slope break and the primary structure. (2) Rear Setback. (a) Maintenance and revegetation of downslopes to property lines shall be ensured through use of slopes no greater than a 3:1 ratio, which may be used in combination with retaining walls. (b) Where manufactured slopes exceed 20 feet in height, lot depth shall be increased to create additional flat lot area and minimize the visual effect of these slopes. For every foot of slope height over 20 feet, the flat portion of the rear setback area shall be increased by five percent. (c) Manufactured slopes may be used to calculate no more than 25 percent of the required rear setback. (d) Manufactured slopes shall not exceed 30 feet in height. (e) A minimum 15-foot setback from rear dwelling wall to any slope break in excess of a 3:1 ratio shall be provided.
( Ord. 1603 § 4 (Exh. I), 2023 )