§ 17.86.030 — Outdoor lighting

Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 17.86.030

Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/10d99235-05f3-41ba-bdd9-884da4b68fda

§ 17.86.030: Outdoor lighting.

(A) Applicability. The standards of this Section shall apply to all new development and to exterior alterations and additions that involve replacement light fixtures or systems, except as provided below. (1) Exceptions. The following outdoor lighting shall not be subject to the provisions of this Section: (a) Public and private street lighting. (b) Construction and Emergency Lighting. All construction or emergency lighting fixtures, provided they are temporary and are discontinued immediately upon completion of the construction work or abatement of the emergency. (c) Temporary Lighting. Temporary lights used for holiday decorations, and lighting for temporary uses and special events allowed consistent with this Title. (B) Photometric Plan. The submittal of a photometric plan shall be required as part of a development application or land use approval (except for lighting on an existing single-family residence) and shall be approved prior to issuance of building permits. All lighting plans shall be prepared and certified for compliance with the requirements of this Section by an electrical engineer registered in the State of California prior to submitting lighting plans to the City. The photometric plan shall consist of a point-by-point foot-candle layout (based on a 10-foot grid center) extending a minimum of 20 feet outside the property lines. (C) Prohibited Lighting. The following types of outdoor lighting shall be prohibited: (1) Searchlights. Searchlights, laser source lights, or any similar high-intensity light, except for emergency use by police or fire personnel at their discretion, or for approved temporary lighting for a special event approved by the City. (2) Hazardous Lighting. Lighting fixtures operated in such a manner as to constitute a hazard or danger to persons or to safe vehicular travel. (3) Mercury vapor and low-pressure sodium lighting fixtures. (4) Illumination of entire buildings and continuous light strips (banding). (5) Roof-Mounted Lighting. Roof-mounted lighting is prohibited, except for security purposes (see Subsection (D)(8) of this Section (Security Lighting)). (6) Flashing Light Types. Moving, flashing, animated, laser lights or any other lighting that flashes, blinks, scrolls, alternates, or moves (excluding bi-level lighting). (D) General Requirements. The requirements listed below shall apply to all outdoor lighting: (1) Dark-Sky Compliance. Pursuant to the International Dark-Sky Association recommendations, the color temperature of outdoor lighting shall not exceed 3,000 Kelvins. (2) Nuisance Prevention. All outdoor lighting shall be designed, located, installed, directed downward or toward structures, fully shielded, and maintained in order to prevent glare, light trespass, and light pollution and away from adjoining properties and public rights-of-way, so that no light fixture directly illuminates an area outside of the project site intended to be illuminated. [image] (3) Light Trespass. All lights shall be directed, oriented, and shielded to prevent light trespass or glare onto adjacent properties. The light level at property lines shall not exceed one-quarter foot-candles. (4) Fixture Types. All luminaires shall meet the most recently adopted criteria of the Illuminating Engineering Society of North America (IESNA) for "Cut Off" or "Full Cut Off" luminaires. (5) Design. All light fixtures for nonresidential projects visible to the general public shall be consistent with the overall architectural style of the project with respect to design, materials, color, and color of light. (6) Attachment. Lighting fixtures on buildings shall be attached only to walls or eaves, and the top of the fixture shall not exceed the height of the parapet, roof, or eave of the roof. (7) Accent Lighting. (a) Architectural features may be illuminated by uplighting; provided, that the lamps are low intensity, and fully shielded such that no glare or light trespass is produced. (b) Exposed neon strips, chip strips, and LED lighting are allowed in the nonresidential zones to enhance the architectural features of the building. (c) Low-voltage string ornamental lighting may be used in mixed-use, commercial/office, and PF (Public Facilities) zones to accentuate landscaping or decorative architectural features, provided the fixtures are properly maintained, securely attached to the structure, and provide architectural lighting to the building facade. (8) Security Lighting. Security lighting fixtures shall not project above the fascia or roof line of the building on which they are mounted. All security lighting fixtures shall be shielded and aimed so that the illumination is directed only to the designated area and shall not cast direct light on other areas. The use of flood-lighting fixtures shall be prohibited. Security lighting fixtures shall be included in the photometric lighting plan. (9) Signs. Lighting of signs shall be in compliance with PMC Chapter 17.88 (Signs). (10) Maintenance. Fixtures and lighting shall be maintained in good working order and in a manner that serves the original design intent. (a) Lighting fixtures shall be weather and vandal resistant. (b) Burnt-out and broken light bulbs shall be replaced. (c) Lighting fixtures shall remain free of graffiti and rust. (d) Painted light fixtures shall be maintained to minimize chipping or peeling. (11) Timing Controls. All outdoor lighting in nonresidential zones shall be on a time clock or photo-sensor system and turned off during daylight hours and during hours when the building(s) is not in use and the lighting is not required for security. (12) Energy-Efficient Fixtures Required. Outdoor lighting shall utilize energy-efficient fixtures and lamps such as metal halide, hard-wired compact fluorescent, LED, or other lighting technology that is of equal or greater efficiency. All new outdoor lighting fixtures shall be energy efficient with a rated average bulb life of not less than 10,000 hours. (E) Maximum Height of Freestanding Outdoor Light Fixtures. Height shall be measured from the finished grade to the top of the illumination fixture (excluding decorative elements on the top of the fixture). (1) Abutting Residential Zones. The maximum height of on-site freestanding outdoor light fixtures abutting residential zones or within 100 feet of the zone boundary shall be 15 feet. (2) Mixed-Use or Multifamily Zones. The maximum height of an on-site freestanding outdoor light fixture within a mixed-use or multifamily residential zone shall be 15 feet. (3) Industrial Zones. The maximum height limit for on-site freestanding outdoor light fixtures in industrial zones and public/civic uses consistent with industrial zones shall be 35 feet. (4) Other Zones. In all other zones or locations, the maximum height for on-site freestanding outdoor light fixtures shall be 25 feet. (5) Outdoor Recreational Facilities. Outdoor light fixtures within the PF (Public Facility) zones for active recreation (public or private) including, but not limited to, baseball diamonds, soccer and football fields, golf driving range, tennis courts, and swimming pools shall not exceed 70 feet in height. The lighting intensity shall not exceed 50 horizontal foot-candles measured from the infield. The installation shall limit off-site spill (off the parcel containing the sports facility) to the maximum extent possible consistent with the illumination constraints of the design. The luminaire shall be fully shielded. (6) Additional Height. Taller light fixtures may be approved through a minor use permit for portions of a development not visible to the public and if there is no glare or light trespass into areas visible to the public. (F) Minimum Lighting Requirements. (1) Parking Areas. Lighting in parking, garage, and carport areas shall be maintained with a minimum of one-half foot-candle illumination at the darkest spot on the parking area during hours of darkness. There shall be no more than a four-to-one (4:1) average illumination ratio (average to minimum) level of illumination shown between lighting fixtures. The maximum average illumination across the parking lot shall be no more than 2.4 foot-candles. All lighting shall be on a time-clock or photosensor system. Lighting used to illuminate parking areas shall be designed and located to prevent light trespass or glare, pursuant to Subsection (D)(2) of this Section (Nuisance Prevention). (2) Multi-Unit Residential Developments. Aisles, passageways, and entryways/recesses related to and within the building complex shall be illuminated with an intensity of at least one-quarter foot-candle at the ground level during the hours of darkness. (3) Nonresidential Developments. All exterior doors, during the hours of darkness, shall be illuminated with a minimum of one-quarter foot-candle of light.

( Ord. 1603 § 4 (Exh. I), 2023 )

Ask a question about Palmdale law

Corpus searches the Palmdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.