§ 17.96.060 — Contents of application

Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 17.96.060

Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/c281fb70-75d6-4279-8444-6b8062e5c281

§ 17.96.060: Contents of application.

Every application for a facility pursuant to this Title shall be made in writing to the Director on the forms provided by the Planning Division and must be in sufficient detail to facilitate thorough review. All applications shall be accompanied by the appropriate filing fees as established by City Council resolution. An application shall include, but is not limited to, the following information: (A) Name and address of the applicant; (B) Evidence that the applicant is the owner of the premises involved or that it has written permission of the owner to make such application; (C) A site plan drawn in sufficient detail to clearly describe the following: (1) Physical dimensions of the property and structures; (2) Location of existing and proposed structures, including elevations; (3) Setbacks and landscaping; (4) Methods of circulation and parking; (5) Drainage patterns; (6) Ingress and egress; (7) Storage and processing areas; (8) Proposed utilization of property; (9) The distance from the facility property line to the nearest adjacent structure, and a description and location of such structure; (10) The distance to nearest residences, to properties designated in the General Plan for residential use, to proposed or presently zoned residential areas, and to immobile populations; (11) Proximity of the proposed facility to the 100-year flood prone areas; (12) Proximity of the proposed facility to any known active or potentially active earthquake faults as defined by the California State Department of Mines and Geology; (13) The relationship of the proposed facility to all surface water bodies, and all known underground aquifers beneath the facility or beneath the ground adjacent to the facility; (14) Topographic description and plotting of the property and surrounding area on a topographic map; (15) A preliminary geological study of the property and surrounding area including data on the permeability of the substrata; (16) Existing and proposed utilities which service or will be required to service the facility; and (17) A radius and vicinity map including the project boundary; (D) A list of adjacent property owners and a map indicating their location relative to the proposed facility; (E) An environmental assessment questionnaire; (F) A grading plan; (G) A title report completed within six months of the date of facility application submittal; (H) A legal description of the site; (I) Identification of any other hazardous materials facilities presently or in the past owned or operated by the applicant, with copies of all permits and a listing of regulatory and community contracts for each facility, with their affiliations and current phone numbers; (J) Full disclosure of any past or present permit violations and any past or pending administrative, civil, or criminal proceedings or litigation involving any facility in any location presently or in the past owned or operated by the applicant, or proposed for operation by the applicant; (K) Disclosure of any past or present air, water, soil, or other property contamination that has resulted from any activity of the applicant, or that has occurred at any facility owned or operated by the applicant; (L) Financial statements from the applicant including proposed means for financing development of the facility, and anticipated costs and revenues associated with the operation of the facility; (M) Detailed information regarding how the applicant will meet State pollution liability insurance requirements for sudden and nonsudden events, and State requirements for funding closure and postclosure costs; (N) Identification of the amounts (in tons), sources, and types of hazardous materials to be treated or stored at the proposed facility; the geographical location of the producers; the ultimate disposition of the hazardous materials; and anticipated life of the facility. This information will be based on an actual survey of the industries to be served and be representative of the hazardous materials that will be processed at the facility; (O) Identification of the type(s) of processes that will be used at the facility. For any proposed facility other than storage or recycling, specification of whether any anticipated hazardous materials streams meet the definition of "recyclable material" pursuant to California State Health and Safety Code Section 25120.5 or are listed by the State as recyclable hazardous materials pursuant to California State Health and Safety Code Section 25175. If either of these conditions exist, an explanation of why these hazardous materials should not be recycled shall be provided; (P) Identification of all wastewaters, treated and untreated, generated by the proposed facility, the method and place of final discharge, and a copy of the required State waste discharge permit pursuant to California State Water Code, Division 2, Chapter 4, Article 4, Section 13260, et seq., and National Pollutant Discharge Elimination System (NPDES) permit applications, pursuant to 40 Code of Federal Regulations 122; (Q) A copy of the facility's hazardous materials storage permit application and business plan, prepared pursuant to Section 2.20.140 of the Los Angeles County Code and California State Health and Safety Code Section 25503; (R) An analysis of visual, noise, and any olfactory impacts associated with the proposed facility and recommended mitigation measures; (S) An analysis of vehicle miles traveled and any potential transportation impacts and recommended mitigation measures; (T) An analysis of all anticipated air quality impacts associated with the proposed facility, including the effect of wind patterns at the site, proposed mitigation measures to ensure no degradation of air quality in the area, and a copy of all required permits from the Antelope Valley Air Quality Management District, or any other agency; (U) Identification of any rare or endangered species of plant or animals within the proposed facility site and recommended impact mitigation measures; (V) Identification of any cultural resources located on the proposed facility site, including archaeological, paleontological, and historical resources, and proposed mitigation measures to ensure no significant impact on cultural resources occurs; (W) The results of preliminary studies of the impact of the proposed facility on real property values and local employment patterns; (X) A health and environmental risk assessment based on a worst-case accident scenario resulting from an upset condition involving hazardous materials. If the proposed facility will include any hazardous materials listed on the United States Environmental Protection Agency's list of extremely hazardous substances (pursuant to Federal Register Volume 52, No. 77, page 13,397), a risk management prevention program pursuant to Chapter 6.95, Article II, Section 25531 of the California State Health and Safety Code shall also be submitted. Mitigation measures for all potentially significant impacts shall be recommended. The proposed scope, protocol, and methodology of the risk assessments will be submitted to the Director for approval prior to the initiation of the risk assessments; (Y) A health and environmental risk assessment that analyzes, in detail, all possibilities and probabilities of accidents or spills involving hazardous materials to be used at the site, transportation-related accidents from the points of origin to the facility, and any other probabilities requested by either the Director or the Review Authority. The proposed scope, protocol, and methodology of the risk assessments will be approved by the Director prior to starting the necessary work. Such analyses shall identify mitigation measures to reduce the identified risks. The risk assessment shall identify the transportation routes which will yield the least risk of accident and environmental impact resulting from trucks hauling hazardous materials to the proposed facility; (Z) A plan that identifies an ongoing monitoring program of air, soil, groundwater, and other environmental systems. This plan must include any monitoring requirements imposed by other permitting agencies including, but not limited to, the Antelope Valley Air Quality Management District, the Regional Water Quality Control Board, and the State Department of Health Services; (AA) Documentation of how the proposed facility will serve the needs of local producers of hazardous waste, including household hazardous wastes; (BB) All applications must contain a designation of at least two reasonable alternative sites; and (CC) An application for an off-site facility must include a detailed proposed public education and participation program to be employed during the local land use decision-making process and which shall be subject to review and approval by the Director.

( Ord. 1603 § 4 (Exh. I), 2023 ; Ord. 1613 § 4 (Exh. I), 2023 )

Ask a question about Palmdale law

Corpus searches the Palmdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.