§ 14.08.090 — Minimum standards
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.08.090
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/e52ae336-23fe-4520-8584-0c9b1c7041ea
14.08.090 - Minimum standards.
A. Scope of Analysis. This chapter requires the alteration, repair, replacement or addition of structural elements to meet the strength and stiffness in conformance with the building code except as modified herein. The lateral-load-path analysis shall include the resisting elements and connections from the wood diaphragm immediately above any soft, weak or open-front wall lines to and including the foundation. Stories above the weak wall line shall be considered in the analysis but need not be modified. The engineer shall investigate existing conditions as applicable for the required analysis, including performing initial material testing and verification of existing conditions. B. Design Base Shear and Design Parameters. The design force in a given direction shall not be less than 75 percent of that derived from the base shear as determined from the seismic provisions of the American Society of Civil Engineers (ASCE) standards that are currently in effect, with design parameters as specified by the current City Seismic Design Guidelines. The structure shall be analyzed and/or strengthened in order to mitigate the weak and/or soft wall line deficiencies defined in Section 14.08.030. Exception: Alternatively, the structure may be retrofitted per the currently adopted Guidelines for the Seismic Retrofit of Existing Buildings in the California Existing Building Code, provided the entire story is analyzed and/or strengthened in order to mitigate the weak and/or soft wall line deficiencies defined in Section 14.08.030. C. Lateral Vertical Systems. Strengthening systems with concrete walls or masonry walls, or steel braced frames shall be not be permitted unless a full building analysis considering diaphragm stiffness and torsional behavior is performed. D. Horizontal Structural Irregularities in Buildings with Three or More Stories. Structures with three or more stories having horizontal structural irregularities of either type 2, 3, 4, or 5 listed in the currently adopted ASCE, "Horizontal Structural Irregularities," shall be altered to meet the additional requirements of those sections referenced in the table for the weak, soft or open-front wall lines being considered. E. Alternate Analysis, Base Shear and Design Parameters. The building official may approve alternate analysis and/or design methodologies that meet the same performance intent as those prescribed by this chapter and that achieve the objectives established by this chapter. A design criteria shall be submitted to the city for review and approval prior to submission of plans. F. Additional Anchorage Requirements for Buildings on Hillsides. Where any portion of a building within the scope of this chapter is constructed on or into a slope steeper than one-unit vertical in three units horizontal (33 percent slope), the lateral-force-resisting system, at and below the base level diaphragm, shall also be analyzed for the effects of concentrated lateral loads caused at the building base from the hillside conditions and comply with the provisions of the City Seismic Design Guidelines. G. Story Line Drift Limitations. The story drift at the strengthened line shall not exceed the allowable deformation as specified in the City Seismic Design Guidelines. H. Pole Structures. The effects of rotation and soil stiffness shall be included in the calculated story drift where lateral loads are resisted by vertical elements whose required depth of embedment is determined by pole formulas. The coefficient of subgrade reaction used in deflection calculations shall be based on an approved geotechnical investigation conducted in accordance with approved geotechnical engineering reports. I. P-Delta Effect. P-Delta effects shall be considered as specified in the City Seismic Design Guidelines. J. Ties, Continuity and Collectors. All parts of the structure included in the scope of analysis shall be interconnected and the connection shall be capable of resisting the seismic force created by the parts being connected as required per the building code.
(Ord. No. 7345, § 3, 5-20-2019)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.
