§ 17.30.070 — Frontage
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.30.070
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/f49b3c18-b459-4796-8e13-b4a99b3aaeea
17.30.070 - Frontage
These standards are intended to: • Promote an active, accessible, and attractive pedestrian environment at the ground level; • Activate the pedestrian street experience through design and use standards; • Enable flexibility and adaptability over time through quality design; and • Support a livable urban setting comprised of a range of uses in a comfortable pedestrian environment. A. Ground Floor Frontages. In Mixed-Use zoning districts, ground floor use requirements are regulated by frontage type per Figure CDSP-19 and Table CDSP-5. All use requirements are regulated as a percentage of the building frontage. 1. Commercial Uses. Frontage types shall require a minimum amount of the building frontage to be comprised of, and designed for, commercial uses per Figure CDSP-19 and Table CDSP-5; see Figure CDSP-20. Permitted commercial uses by zoning district are found in Table CDSP-1. a. Entrances to non-ground floor uses, and/or entrances to uses prohibited within 35 feet of the sidewalk, shall not qualify toward the minimum commercial use percentage. b. Commercial uses shall have an average interior depth of at least 35 feet and a minimum depth of 20 feet, measured wall-to-wall. 2. Residential Uses. Frontage types set limitations on ground floor residential uses facing the street per Figure CDSP-19 and Table CDSP-5. Permitted residential uses by zoning district are found in Table CDSP-1. a. Type A: Residential units on the ground floor shall be prohibited within 35 feet of the sidewalk line, inclusive of setbacks, per Table CDSP-5; see Figure CDSP-21. b. Type B: Residential units on the ground floor shall be permitted with direct access to the street and a minimum setback of 5 feet. c. Residential common space on the ground floor shall be permitted per Table CDSP-5. Figure CDSP-19: Ground Floor Frontage Types [image omitted; see the official code] Table CDSP-5: Allowable Ground Floor Building Frontages in Mixed-Use Zones Type | Commercial Uses | Residential Common Space | Residential Dwelling Units 1A | 80% min. | 20% max. | Prohibited within 35' of sidewalk line 2A | 20% min. | 80% max. 3A | Allowed, no percentage requirements 2B | 20% min | 80% max 3B | Allowed, no percentage requirements Figure CDSP-20: Ground Floor Commercial Uses [image omitted; see the official code] Figure CDSP-21: Ground Floor Residential Units [image omitted; see the official code] B. Ground Floor Design. 1. Entrances. A minimum of one primary entrance shall be located on the primary frontage of each building and open onto a sidewalk or other public space. a. Primary entrances shall be distinguished by architectural features or overhead projections, such as an awning or canopy. b. All entrances shall be recessed a minimum of 30 inches from the sidewalk line. 2. Minimum Height. Buildings shall have a minimum ground floor height of 15 feet, measured from the sidewalk elevation closest to the primary entrance to the second story floor or roof of a one-story building; see Figure CDSP-22. a. Exception. Ground floor residential uses with a setback of 10 feet or greater shall have a minimum ground floor height of 12 feet. b. For non-residential and residential common space uses, the primary entrance of the first habitable floor shall be located at existing grade along the sidewalk line. c. For residential units, the first habitable floor shall be located between 6 feet above and 2 feet below the sidewalk elevation. Figure CDSP-22: Ground Floor Height [image omitted; see the official code] C. Transparency. 1. Windows & Doors. Street-facing façades shall incorporate glass providing views into work, display, sales, lobby, or similar active areas. The minimum transparency requirement is 70 percent for ground floors and 30 percent for the overall façade. For residential units, transparency requirements are reduced to 15 percent each for ground floor and the overall façade. a. For non-residential and residential common space uses, ground floor transparency is measured as the percentage of building frontage that consists of transparent openings between a height of 2 feet and 10 feet above the sidewalk elevation. b. All other transparency is measured as the percentage of building frontage area, viewed in elevation and excluding any coverage of shading devices. c. Windows shall be recessed by a minimum of 3 inches, measured from the outside wall to the frame of the window (mullion, muntin or similar element). Flush windows shall be permitted where exterior shading devices cover a minimum of 25 percent of the window surface area or per review authority approval. d. The use of tinted, mirrored, or highly reflective glass is prohibited. e. Blinds, drapes, posters, and shelving for product displays visible to the public right-of-way shall obscure a maximum of 10 percent of the transparent areas of each respective storefront or 50 percent for medical office uses. 2. Blank Walls. Windowless expanses of street-facing walls shall not exceed 20 feet in length. 3. Security Bars. Any exterior or interior security bars shall be designed to be fully hidden from view during business hours with devices such as concealed side pockets and ceiling cavities. D. Shade Structures. 1. Awnings & Canopies. Any ground floor shading shall project a minimum of 3 feet from the façade and allow a minimum of 8 feet of vertical clearance from the sidewalk elevation. a. Shade structures shall not conflict with existing trees; exceptions to the depth requirement shall be subject to review authority approval. 2. Colorado Boulevard. For projects on the north side of Colorado Boulevard, shade structures are required and shall project a minimum of 7 feet, up to a maximum of 10 feet, into the public-right-of-way for a minimum of 70 percent of the building frontage. a. Where an arcade or recessed ground floor provides a minimum of 5 feet of unobstructed pedestrian clearance, shade structures are not required. E. Arcades & Galleries. 1. Arcades. Any arcades shall be located behind the minimum setback. a. Arcades shall be a minimum of 8 feet from back of column to building façade. b. The distance between columns shall be equal to or greater than the arcade depth dimension, as measured from the column center. c. The façade within the arcade shall meet the ground floor transparency set in Section 17.30.070.C. d. Uses allowed within arcades include pedestrian travel, seating/street furniture, outdoor dining, landscape planters, and/or bicycle parking. 2. Galleries. Any galleries shall be located behind the minimum setback. a. Galleries shall be limited to one-story and 50 percent of the building frontage. b. Galleries shall allow a minimum of 10 feet of vertical clearance from the sidewalk elevation. F. Exterior Fixtures. 1. Façade Lighting. Lighting shall be located on façades facing streets and public open spaces at a frequency of every 30 feet or less. a. Façade lighting shall be full cutoff (directing light downward and outward). b. Fixtures shall be located between 8 and 15 feet above the sidewalk elevation, and shall not project more than 30 inches from the façade. c. For buildings with ground floor residential uses, façade lighting shall be designed to be operable by the adjacent tenant. d. Façade lighting shall not be required on buildings located on Colorado Boulevard, designated historic resources and districts, and within the In-town Residential subarea. 2. Venting. Interior exhaust shall be vented through the roof. Venting that must be routed through the façade due to Building Code requirements shall meet the following criteria: a. Vents shall be located on secondary façades where possible. b. Vents shall be screened by decorative caps or painted to match the façade. c. Vents shall be centered or consistently aligned with another architectural element, such as score lines, windows, or vertical planes. G. Walls & Fences. 1. Walls & Fences. Freestanding walls, fences, and raised/landscape planters are permitted within the street setback. a. Walls and fences shall have a maximum height of 48 inches above the sidewalk elevation. b. Walls and fences taller than 30 inches shall be a minimum of 50 percent transparent and set back a minimum of 18 inches from the sidewalk line, separated by planted area. Walls and fences 30 inches or less in height do not have a transparency or setback requirement. c. Walls and fences used to enclose outdoor dining may be located at the sidewalk line and are not required to provide a planted area if the wall or fence is 36 inches or less and more than 50 percent transparent. d. Guardrails may exceed the maximum height to the extent required by the Building Code. The guardrail shall be a minimum of 50 percent transparent. 2. Stoops & Patios. The side of a patio or stoop (when parallel to a sidewalk) taller than 30 inches in height shall be set back a minimum of 18 inches from the sidewalk line, separated by planted area. H. Balconies & Roof Decks. 1. Balconies. Balconies may project a maximum of 4 feet from the building façade but shall not extend beyond the sidewalk line or within 6 feet of any interior property line. 2. Roof Decks. The sum of all roof decks on a single building shall not exceed a maximum coverage of 60 percent of the roof area. a. Roof deck railings on the uppermost 2 stories shall be set back a minimum of 5 feet from the façade.
(Ord. No. 7419, § 2, 2-26-2024)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.
