For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.31.070 — Scale Standards

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.31.070

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/397eac93-aa1b-4ce7-9508-0c185bb94caa

17.31.070 - Scale Standards

These standards are intended to: • Implement the General Plan density (du/ac) and floor area ratio (FAR) values; • Shape development in a manner that creates a defined public realm and appropriate scale of buildings for a visually appealing community; • Reduce building massing through setback and stepback requirements that create appropriate transitions to residential neighborhoods; • Support high-quality architecture and urban design through modulation requirements and a varied roof lines incentive; and • Require appropriate transitions to designated historic resources. A. Density 1. Residential Density. Projects that include residential dwelling units shall not exceed the allowable dwelling units per acre (du/ac) per Figure ECSP-5. a. Fractions shall be rounded to the nearest whole number; those at 0.50 may be rounded up. b. For projects utilizing state density bonus, refer to Government Code 65915. c. The maximum is based on total site area. If a street dedication or easement is required, density shall be calculated using the size of the lot prior to the street dedication or easement. 2. Unit Mix. For projects west of Hill Avenue with 50 dwelling units or more, inclusive of any density bonus, at least 20 percent of the total number of units shall have a minimum of 3 bedrooms. a. Fractions shall be rounded to the nearest whole number; those at 0.50 shall be rounded up. Figure ECSP-5: Residential Density [image omitted; see the official code] B. Intensity 1. Floor Area Ratio. .....Projects that include non-residential space, including mixed-use, shall not exceed the allowable floor area ratio (FAR) per Figure ECSP-6. a. In mixed-use projects, residential floor area is included in FAR. b. Areas used exclusively for vehicle and bicycle parking and loading are excluded from FAR. c. The maximum is based on total site area. If a street dedication or easement is required, FAR shall be calculated using the size of the lot prior to the street dedication or easement. Figure ECSP-6: Floor Area Ratio [image omitted; see the official code] C. Height 1. Building Height. Projects shall not exceed the height limits set in Figure ECSP-7. a. Height is measured per Section 17.40.060. b. Maximum height for massing adjacent to street or interior property lines may be limited by required stepbacks; see Section 17.31.070.E. c. Exceptions allowed for Varied Roof Lines (Section 17.31.070.C.2) and projecting features such as appurtenances and railings per Section 17.40.060. Figure ECSP-7: Building Height [image omitted; see the official code] 2. Varied Roof Lines. A maximum of 30 percent of a building's footprint may exceed the height limit set in Figure ECSP-7 by up to 12 feet. a. This allowance is not applicable to other development standards relating to building scale such as stepbacks. It may not be used in combination with the height concession set in Section 17.43. 3. Streetwall Height. Buildings shall meet or exceed the minimum streetwall height set in Table ECSP-4 for a minimum of 75 percent of building frontage, unless the overall building height is lower than the requirement; see Figure ECSP-8. a. Streetwall is defined as any street-facing façade within 10 feet of the maximum setback and is not required to be continuous. b. Appurtenances shall not count toward streetwall height. Table ECSP-4: Streetwall Height Allen Avenue, north of Walnut | 35' min. Colorado Boulevard | 25' min. Figure ECSP-8: Streetwall Height [image omitted; see the official code] D. Setbacks 1. Street Setbacks. Buildings shall comply with the street setbacks set in Figure ECSP-9. Setback ranges establish a minimum and maximum for the specified percentage of linear frontage; see Figure ECSP-10. a. Street setbacks are measured from the sidewalk line; see Figure ECSP-3. b. Minimum setbacks shall apply to all stories of a building; setbacks less than the minimum are prohibited. Maximum setbacks shall apply only to the ground floor and Streetwalls (Section 17.31.070.C.3), where applicable. c. Residential units on the ground floor shall have a minimum setback of 5 feet. Where elevated between 4 and 6 feet above sidewalk elevation, a minimum setback of 8 feet shall be required. d. Exceptions allowed per Section 17.40.160 (Table 4-1) and the following: (1) Arcades and recessed ground floors up to 15 feet in depth, as well as parking entrances per Section 17.31.100.B, are allowed when a second story or roof meets the setback range; see Figure ECSP-11. (2) The specified frontage percentage may be reduced for the provision of Publicly Accessible Open Space facing the street through the Design Review process with Design Commission approval. (3) For Restaurants in EC-MU-G, the primary frontage percentage may be reduced to 40 percent if an additional 10 percent is provided as a solid wall of 36 to 48 inches enclosing outdoor dining. e. Features allowed within the street setback include: landscaping and planters, hardscape (e.g. stoops, patios), shade structures per Section 17.31.080.D, arcades and galleries per Section 17.31.080.E, exterior features per Section 17.31.080.F, walls and fences per Section 17.31.080.G, seating and furniture, outdoor dining, and other open space amenities per review authority approval. f. For portions of buildings set back from the sidewalk line 5 feet or more, a percentage of the setback area shall be landscaped with trees, shrubs, and/or groundcover, either in the form of in-ground landscaping or planters. Frontages with shared entrances to internal circulation | 50% Frontages with individual residential unit entrances | 30% with a stoop taller than 30 inches | 10% Frontages with individual commercial tenant entrance | 30% with outdoor dining | 10% Figure ECSP-9: Street Setbacks [image omitted; see the official code] Figure ECSP-10: Street Setbacks Percentage [image omitted; see the official code] Figure ECSP-11: Recessed Ground Floor [image omitted; see the official code] 2. Interior Setbacks. Buildings shall be set back a minimum of 15 feet from an interior property line that is adjacent to a PS or RM zoning district. No setback is required when adjacent to other districts. a. Interior setbacks are those abutting other parcels along non-street side and rear property lines and are measured from the shared property line. b. Exceptions allowed per Section 17.40.160 (Table 4-1). E. Stepbacks 1. Street Stepbacks. Buildings shall not exceed the height specified in Table ECSP-5 before stepping back the specified depth; see Figure ECSP-12. a. Street stepbacks are measured from the sidewalk line. b. Uses allowed within the street stepback include: private open space (e.g. balconies, terraces), shade structures, trellises, and similar, green roofs and photovoltaic panels, and other open space features per review authority approval. Table ECSP-5: Street Stepbacks Project type | Depth | Height Colorado Boulevard | 15' | 51' Green Street | 8' | 20' 50' | 51' All other streets | 8' | 45' Figure ECSP-12: Street Stepbacks [image omitted; see the official code] 2. Interior Stepbacks. Adjacent to RM zoning districts, buildings shall not be located within the encroachment plane sloping upward and inward at a 45-degree angle measured from the vertical, commencing 25 feet above the existing grade along the shared property line; see Figure ECSP-13. a. Exceptions allowed per Section 17.40.160 (Table 4-2.1). Figure ECSP-13: Interior Stepbacks Adjacent to RM Zoning Districts [image omitted; see the official code] F. Historic Adjacency 1. Landmark Properties. Projects on parcels with a designated historic resource shall be subject to review for consistency with the Secretary of the Interior's Standards. 2. Transition Massing. Projects sharing a property line with a designated historic resource are subject to the following modified standards, illustrated in Figure ECSP-14. a. Street Setbacks. The minimum street setback shall be an average of the minimum setback set in Figure ECSP-9 and that of the resource for a minimum of 20 feet from the shared property line. If located between two resources, the street setback shall be an average of the setbacks of the two resources. b. Interior Setbacks. The minimum interior setback shall be equal to that of the historic resource or 15 feet, whichever is less. No setback is required where the resource is built to the shared property line. c. Streetwall Height. A maximum streetwall height shall not exceed the height of the historic resource for a minimum of 20 feet from the shared property line. A stepback with a minimum depth of 10 feet is required above this height, measured from the modified minimum street setback. d. Interior Stepbacks. Projects shall not be located within an encroachment plane sloping upward and inward at a 30-degree angle measured from the vertical, commencing 15 feet above the existing grade at the property line; see Figure ECSP-14. This plane is not applicable if the resource is built to the shared property line. Figure ECSP-14: Historic Adjacency [image omitted; see the official code] G. Modulation 1. Façade Length. Each street-facing façade shall not exceed 150 feet in length unless there is a minimum break of 10 percent of the building length or 20 feet, whichever is greater. This break shall be at least 10 feet deep, open to the sky; see Figure ECSP-15. 2. Façade Area. Each street-facing façade exceeding 50 feet in length shall modulate a minimum of 25 percent of the area above the first story. This modulation shall be between 2 feet and 12 feet in depth from the primary facade plane; see Figure ECSP-16. Buildings with a total of 2 stories or less are exempt. a. The primary façade plane is defined as the vertical plane with the greatest surface area above the ground floor. b. Planes that are separated by a break of at least 20 feet in width and 10 feet in depth shall be considered separate façades for the purposes of this standard. c. Modulation is not required to be continuous or open to the sky, and may be recessed or projected, but not past the sidewalk line. d. Required stepbacks (Section 17.31.070.E), required façade breaks (Section 17.31.070.G.1), and projected balconies (Section 17.31.080.G.1) shall not count toward the modulation requirement; balconies that are recessed a minimum of 2 feet shall qualify. Figure ECSP-15: Facade Length | Figure ECSP-16: Facade Area [image omitted; see the official code] | [image omitted; see the official code] 3. Alternative Compliance a. Eligibility. Modulation standards may be reduced or otherwise modified through the Design Review process if: (1) A minimum of 90% of the provided parking is fully or partially subterranean; (2) A minimum of one publicly accessible open space is provided at the ground level, visible and accessible from the sidewalk; (3) No other concessions, waivers, or incentives have been requested, including those associated with Section 17.43 (Density Bonus), unless the project is designed to achieve LEED Gold certification; and (4) The review authority makes all of the following findings. b. Required Findings. (1) The building design provides modulation on each street-facing façade in a manner consistent with the project's architectural style and/or immediate context, including adjacent historic resources. (2) The building design does not cause an adverse impact on the quality of the ground floor and public realm. (3) The ground level open space is of adequate size and integrated with the building in a functional way that ensures the space will be actively utilized. (4) The modification will not be detrimental to the health, safety, and welfare of the public. (5) The building design is consistent with the objectives and policies of the General Plan and ECSP, as well as all other standards of the ECSP.

(Ord. No. 7446, § 5, 5-12-2025; Ord. No. 7394, § 3(Exh. 2), 6-13-2022)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.