§ 17.38.060 — Scale Standards

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.38.060

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/fd9ea686-94d2-408b-8cf6-0c474c5d00e0

17.38.060 - Scale Standards

These standards are intended to: • Implement the General Plan density (du/ac) and floor area ratio (FAR) values; • Shape development in a manner that creates a defined public realm and appropriate scale of buildings for a visually appealing community; • Reduce building massing through setback and stepback requirements that create appropriate transitions to residential neighborhoods; • Support high-quality architecture and urban design through modulation requirements and a varied roof lines incentive; • Encourage industrial growth in modern fields such as life sciences, production, research & development, and technology; • Require appropriate transitions to designated historic resources; and • Support opportunities to increase housing near transit, and require various unit sizes to support individuals and families. A. Density 1. Residential Density. Projects that include residential dwelling units shall not exceed the allowable dwelling units per acre (du/ac) set in Figure LPSP-6. a. Fractions shall be rounded to the nearest whole number; those at 0.50 shall be rounded up. b. For projects utilizing state density bonus, refer to Government Code 65915. c. The maximum is based on total site area. If a street dedication or easement is required, density shall be calculated using the size of the lot prior to the street dedication or easement. Figure LPSP-6: Residential Density [image omitted; see the official code] B. Intensity 1. Floor Area Ratio. Projects that include non-residential space, including mixed-use, shall not exceed the allowable floor area ratio (FAR) set in Figure LPSP-7. a. In mixed-use projects, residential floor area is included in FAR. b. Areas used exclusively for vehicle and bicycle parking and loading are excluded from FAR. c. The maximum is based on total site area. If a street dedication or easement is required, FAR shall be calculated using the size of the lot prior to the street dedication or easement. Figure LPSP-7: Floor Area Ratio [image omitted; see the official code] C. Height 1. Building Height. Projects shall not exceed the height limits set in Figure LPSP-8. a. Height is measured per Section 17.40.060. b. Exceptions allowed for Varied Roof Lines (Section 17.38.060.C.2) and projecting features such as appurtenances and railings per Section 17.40.060. 2. Varied Roof Lines. A maximum of 30 percent of a building's footprint may exceed the height limit set in Figure LPSP-8 by up to 12 feet. a. This allowance is not applicable to other development standards relating to building scale such as stepbacks. It may not be used in combination with a concession for building height when utilizing Chapter 17.43. Figure LPSP-8: Building Height [image omitted; see the official code] Figure LPSP-9: Varied Roof Lines [image omitted; see the official code] D. Setbacks 1. Street Setbacks. Buildings shall comply with the street setbacks set in Figure LPSP-12, except where modified for historic adjacency per Section 17.38.060.F. Setback ranges establish a minimum and maximum for the specified percentage of linear frontage; see Figure LPSP- 10. a. Street setbacks are measured from the sidewalk line; see Figure LPSP-3. b. Minimum setbacks shall apply to all stories of a building; setbacks less than the minimum are prohibited. Maximum setbacks shall apply only to the ground floor. c. Exceptions allowed per Section 17.40.160 (Table 4-1) and the following: (1) Arcades and recessed ground floors up to 15 feet in depth, as well as parking entrances per Section 17.38.90, are allowed when a second story meets the specified setback; see Figure LPSP-11. (2) The specified frontage percentage may be reduced for the provision of Publicly Accessible Open Space facing the street through the Design Review process. Figure LPSP-10: Street Setback Percentage [image omitted; see the official code] Figure LPSP-11: Recessed Ground Floor [image omitted; see the official code] d. Residential units on the ground floor, where permitted, shall have a minimum setback of 5 feet. Where elevated between 4 and 6 feet above sidewalk elevation, a minimum setback of 8 feet shall be required. e. In MU-G and MU-N, for portions of buildings set back from the sidewalk line 5 feet or more, a percentage of the setback area shall be landscaped with trees, shrubs, and/or groundcover, either in the form of in-ground landscaping or planters; see Table LPSP-3. Table LPSP-3: Required Landscape Setbacks Frontage with shared entrances to internal circulation | 50% Frontages with individual residential unit entrances | 30% with a stoop taller than 30 inches | 10% Frontages with individual commercial tenant entrances | 30% with outdoor dining | 10% f. In CF, all required setback areas shall be landscaped except walkways, driveways, and utilities required by Building Code. g. Features allowed within the street setback include: landscaping and planters per Chapter 17.44, hardscape (e.g. stoops, patios), shade structures per Section 17.38.070.D, arcades and galleries per Section 17.38.070.E, walls and fences per Section 17.38.070.F, seating and furniture, outdoor dining, and/or other open space amenities per review authority approval. Figure LPSP-12: Street Setbacks [image omitted; see the official code] 2. Interior Setbacks. Projects shall have a minimum setback of 15 feet where adjacent to a RM/RS district. No setback is required along other interior property lines, except where modified for historic adjacency per Section 17.38.060.F a. Interior setbacks are those abutting other parcels along non-street side and rear property lines and are measured from the shared property line. b. Exceptions allowed per Section 17.40.160 (Table 4-1). E. Stepbacks 1. Street Stepbacks. Along Colorado Boulevard, buildings shall not exceed 20 feet in height before stepping back 10 feet in depth, see Figure LPSP-13. a. Street stepbacks are measured from the sidewalk line. i. Uses allowed within the street stepback include: Open Space (e.g., balconies, terraces); shade structures, trellises, and similar; Green roofs are photovoltaic panels; and/or other open space features per review authority approval. 2. Interior Stepbacks. Adjacent to RM/RS zoning, districts, buildings shall not be located within the encroachment plane sloping upward and inward at a 45-degree angle measured from the vertical, commencing 25 feet above the existing grade along the shared property line; see Figure LPSP-14. a. Exceptions allowed per Section 17.40.160 (Table 4-2.1). Figure LPSP-13: Street Stepbacks [image omitted; see the official code] Figure LPSP-14: Interior Stepbacks Adjacent to RM/RS Zoning Districts [image omitted; see the official code] F. Historic Adjacency 1. Landmark Properties. Projects on parcels with a designated historic resource shall be subject to review for consistency with the Secretary of the Interior's Standards. 2. Transition Massing. Projects sharing a property line with a designated historic resource are subject to the following modified standards, illustrated in Figure LPSP-15. a. Street Setbacks. The minimum street setback shall be an average of the minimum setback set in Figure LPSP-12 and that of the resource for a minimum of 20 feet from the shared property line. If located between two resources, the street setback shall be an average of the setbacks of the two resources. b. Interior Setbacks. The minimum interior setback shall be equal to that of the historic resource or 15 feet, whichever is less. No setback is required where the resource is built to the shared property line. c. Streetwall Height. A maximum streetwall height shall not exceed the height of the historic resource for a minimum of 20 feet from the shared property line. A stepback with a minimum depth of 10 feet is required above this height, measured from the modified minimum street setback. d. Interior Stepbacks. Projects shall not be located within an encroachment plane sloping upward and inward at a 30-degree angle measured from the vertical, commencing 15 feet above the existing grade at the property line; see Figure LPSP-15. This plane is not applicable if the resource is built to the shared property line. Figure LPSP-15: Historic Adjacency Transition Massing [image omitted; see the official code] G. Modulation 1. Façade Length. In mixed-use districts, street-facing façade shall not exceed 150 feet in length before a minimum break of 10 percent of the building length or 20 feet, whichever is greater. This break shall be a minimum of 10 feet deep, open to the sky; see Figure LPSP-16. Projects in CF are exempt. Figure LPSP-16: Maximum Façade Length [image omitted; see the official code] 2. Façade Area. Street-facing façades that exceed 50 feet in length shall modulate a minimum percentage of façade area set in Table LPSP-4 a minimum of 2 feet and a maximum of 12 feet in depth from the primary façade plane; see Figure LPSP-17. In mixed-use zoning districts, buildings with a total of 2 stories or less are exempt. Table LPSP-4: Modulated Façade Area CF | MU-G | MU-N Minimum percentage | 20% | 25% Façade area | Overall façade | Above the first story a. The primary façade plane is defined as the vertical plane with the greatest surface area above the ground floor. b. Planes that are separated by a façade break (Section 17.38.060.G.1) shall be considered separate façades for the purposes of this standard. c. Modulation is not required to be continuous or open to the sky, and may be recessed or projected, but not past the sidewalk line. d. Required stepbacks (Section 17.38.060.E), façade breaks (Section 17.38.060.G.1), and projected balconies (Section 17.38.070.G.1) shall not count toward the modulation requirement; balconies that are recessed a minimum of 2 feet shall qualify. Figure LPSP-17: Modulated Façade Area [image omitted; see the official code] 3. Alternative Compliance a. Eligibility. Modulation standards may be reduced or otherwise modified through the Design Review process if: (1) A minimum of 50 percent of the provided parking is fully or partially subterranean; (2) No other concessions, waivers, or incentives have been requested, including those associated with Section 17.43 (Density Bonus), unless the project is designed to achieve LEED Gold certification; and (3) The review authority makes all of the following findings in this subsection (G)(3)(b). b. Required Findings (1) The building design provides modulation on each street-facing façade in a manner consistent with the project's architectural style and/or immediate context, including adjacent historic resources. (2) The building design does not cause an adverse impact on the quality of the ground floor and public realm. (3) The modification will not be detrimental to the health, safety, and welfare of the public. (4) The building design is consistent with the objectives and policies of the General Plan and LPSP, as well as all other standards of the LPSP.

(Ord. No. 7446, § 3, 5-12-2025)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.