For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.40.050 — Flag Lot Development Standards

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.40.050

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/9f9850b3-f84b-45f2-936e-d328332b3421

17.40.050 - Flag Lot Development Standards

The following regulations apply to a subdivision where one or more flag lots are proposed, or where an existing flag lot is to be developed with an addition or a new residence. A. When allowed. A flag lot shall only be allowed: 1. On property zoned RS, and only within the Hillside Development (HD) Overlay District (a flag lot shall not be allowed in the HD-1 Overlay District or any other zoning district); 2. Only if there is no reasonable alternative due to extreme topographic conditions or other physical conditions as determined by the Advisory Agency; and 3. Only when extreme physical constraints and circumstances are inherent. In considering a new flag lot, a conventional subdivision would first have to be possible. B. Required procedure. 1. Subdivision process. A flag lot may be created only through Parcel Map or Tract Map approval; a Lot Line Adjustment shall not be used to create a flag lot. 2. Conditional Use Permit. The creation of a flag lot shall also require Conditional Use Permit approval by the Advisory Agency, in compliance with Section 17.61.050. 3. Geotechnical report. A geotechnical report shall be filed for review and approval by the Building and Safety Division attesting to the stability of the site, before consideration of the subdivision map or Conditional Use Permit by the Advisory Agency. 4. Standards. All lots proposed in flag lot subdivision shall comply with all applicable standards of this Zoning Code, the requirements of the Department, and the requirements of other City departments or divisions including the Department of Public Works, Transportation Department, Fire Department, and the Building Division. C. Design standards. 1. Pole configuration, street frontage. Each flag lot shall be designed to provide a "pole" that functions primarily as an accessway from the street to the main body ("flag" portion) of the lot. Private access easements shall not be allowed. See Figure 4-1. a. A minimum 20 feet, and a maximum 25 feet of frontage and width shall be maintained throughout the length of the pole. b. Driveways shall meet the minimum requirements of Section 17.29.050.F.1. c. The pole portion shall be deemed to end, and the flag portion of the lot shall be deemed to commence, at the extension of the front property line. [image omitted; see the official code] \ Figure 4-1 - Flat lot components 2. Designation of property lines. The following requirements determine the location of the front, side, and rear property lines of a flag lot. a. Front property line. The front property line shall be the lot boundary that most nearly parallels the public or private street providing access to the lot, and which abuts the end of the pole, but does not include the pole. If the pole is not at a 90-degree angle to the front property line, the front property line shall be calculated as if the front property line continued by drawing an imaginary line to the pole. b. Side and rear property lines. (1) The side property line shall be any lot boundary that does not abut a public or private right-of-way, and which is not a front or rear property line, exclusive of the pole portion of the lot. (2) The rear property line shall be the lot boundary opposite the front property line. 3. Measurement of lot depth. Lot depth shall be measured at the midpoints of the front property line, as defined in Subsection B.3, and the rear property line of the flag portion of the lot. When measuring the depth of a flag lot, the pole shall not be included. See Figure 4-2. 4. Lot width. The width of the flag portion of a lot shall comply with the minimum standards of the applicable residential base zoning district. See Figure 4-2. a. Lot width shall be measured by a line connecting two points on opposite side property lines, that will result in a line parallel to the front property line, as defined in Subsection B.2. b. For purposes of measuring the width of a flag lot, the calculation shall not include the pole of the flag lot. 5. Minimum lot area. The flag portion of a flag lot shall comply with the minimum area and dimensions required by the applicable residential base zoning district. a. For purposes of measuring the lot area, only the flag portion shall be considered. b. The flag portion of a flag lot shall not include the pole, or any other portion of the lot where lot width is less than the minimum required by the applicable residential base zoning district. Where the pole is not at a 90-degree angle to the front property line abutting the pole, the front property line shall be calculated as if the front property line continued by drawing an imaginary line, which will also illustrate the boundary of the main body of the lot. 6. Maximum number of lots. The total number of lots in a flag lot subdivision shall comply with the following requirements. a. Where the average slope of a site is 15 percent or less, the total maximum allowable number of lots shall be determined by the applicable residential base zoning district. b. Where the average slope of a site exceeds 15 percent, the total maximum allowable number of lots shall be determined in compliance with Section 17.39.040 (Hillside Subdivision Design Standards). D. Multiple flag lots. Where a subdivision proposes more than one flag lot, the following standards shall apply: 1. Not more than two flag lot poles shall be contiguous to each other. 2. The poles of two flag lots that are contiguous shall have a maximum width of 40 feet. 3. No wall, fence, hedge, or other obstruction, as determined by the Fire Department, shall be constructed or planted within the width of the pole area of the flag lots. 4. Private access easements shall not be allowed. 5. Where a total of three or more lots are created, and two are flag lots with poles that are contiguous to each other, the driveway to the nonflag lots shall be separated from the contiguous poles by a minimum five-foot wide landscaped planter. E. Development standards for flag lots. Where an addition to a residence on a flag lot is proposed, or where a new residence is proposed on a flag lot, the following standards shall apply: 1. Construction and development of a single-family residence and related accessory structures on a flag lot shall only occur in the flag portion of the lot. 2. The maximum gross Floor Area Ratio (FAR) shall be based upon the area of the flag portion of the lot. 3. Each structure on a flag lot shall be oriented to provide the maximum privacy to surrounding existing and future residential structures. a. Large windows and decks on the second floor of a residence on a flag lot shall orient to on-site setback areas and not to surrounding properties. b. Other methods for protecting privacy may include using translucent material in (upper floor) windows, eliminating windows, reducing and/or relocating balconies, or eliminating balconies. 4. The street address of the flag lot shall be placed in a conspicuous location within the pole of the lot that is easily visible from the street. F. Required findings for flag lots. The approval of a Conditional Use Permit for flag lots shall require that the Advisory Agency first make all of the following findings, in addition to the findings required for Conditional Use Permit approval in Section 17.61.050.G (Findings and decision): 1. The proposed flag lot subdivision is the only reasonable subdivision design due to extreme topographic conditions, or other physical and natural constraints of the subject property (e.g., natural drainage course or streams, protected trees, etc); 2. The design of the proposed flag lot subdivision complies with the flag lot development standards identified in this Section; and 3. The lots created from the proposed flag lot subdivision do not adversely impact the established neighborhood character nor deviate from the established neighborhood character, which shall consider the scale of the existing lot sizes and lot configurations in the surrounding area. For purposes of this finding, the surrounding area shall mean all properties within a 1,000-foot radius of the subject property's boundary (before subdivision).

(Ord. 7160 § 24, 2009; Ord. 7057 § 11, 2006; Ord. 7022 § 2 (part) 2005)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.