§ 74-134 — Development criteria
Pomona City Code, California (Supp. No. 32: codified through Ordinance No. 4371, adopted June 2, 2026) · Pomona City Code § 74-134
Corpus is an independent public-information project, not the official City of Pomona website. Stable reference: corpuslaw.us/code/6897cc49-f783-48be-ab7b-fec3241eb99d
Sec. 74-134. - Development criteria.
(a) Work/live units shall be permitted subject to this division in those areas designated as "mixed uses" on the land use map contained within the Downtown Pomona specific plan. (b) Work/live units shall be located in upper stories, basements (below grade) or within the rear portions of the first floor of all commercial buildings located within the mixed use districts of the Downtown Pomona specific plan. (c) Access to work/live areas shall be provided only from common access areas such as hallways, corridors, and exterior portions of the building. Access to and from adjacent work/live units shall be prohibited. (d) Where any unit containing work/live occupancy is adjacent to any other unit containing work/live occupancy, such unit shall be separated by one hour fire resistive floors and walls. (e) Doors opening into corridors shall be protected by 20 minute fire assemblies or solid wood doors, not less than 1¾ inches thick. Where an existing frame will not accommodate a 1¾-inch door, a 1⅜-inch solid, bonded wood core door or equivalent insulated steel door shall be permitted. The doors shall be maintained self-closing or automatic closing by smoke detection. Such doors shall be provided with a gasket so installed as to provide a seal where the door meets the stop on both sides and across the top. (f) It is not intended that the residential component become the primary or dominant use of the building. Not over 50 percent of any individual work/live unit shall be used or arranged for residential purposes such as a sleeping area, kitchen, bathroom, and closet areas. The minimum area of a work/live unit shall be 600 square feet. The residential occupancy in any work/live unit shall not exceed four persons. (g) For the purposes of determining the minimum number of persons for which the building exiting system must be designed, the following occupant load factors shall be used: Occupancy Load Factor Residential use | = | 1 person per 300 sq. ft. Business use | = | 1 person per 100 sq. ft. (h) Each work/live unit shall have one openable window accessible for exiting with not less than a 20-inch by 30-inch opening. (i) The life-safety requirements contained in the California Building Code for existing buildings other than high-rise buildings shall apply to all work/live units. For the purpose of providing a reasonable degree of life safety for individuals occupying work/live units, these requirements shall apply. (j) An automatic fire sprinkler system shall be required on all floors throughout the building when work/live units are located above the third story or in basements. (k) Work/live units located three or more stories in height or in buildings containing 16 or more work/live units shall be provided with an approved manual and automatic fire alarm system. However, a separate fire alarm system need not be provided in buildings which are protected throughout by an approved supervised fire sprinkler system having a local alarm system for the notification of all occupants. (l) All work/live units shall be provided with smoke detectors. Smoke detectors shall receive their primary power from the building's wiring system and shall be provided with battery backup. Detectors shall be installed in accordance with approved manufacturer's instructions. Location of smoke detectors within the building shall be as follows: Within work/live units each work/live unit shall be provided with single station smoke detectors. Smoke detectors shall be mounted on the ceiling at a point centrally located in the residential portion of the unit and in each sleeping room. In the working area of the work/live unit, one hardwired smoke detector shall be centrally located on the ceiling. Where the working area is subdivided into separate rooms, one smoke detector shall be installed on the ceiling of each workroom. (m) A minimum of one 2-A, 10-BC rated fire extinguisher shall be provided in each work/live unit. (n) Any building converted or partly converted to work/live units shall not be considered to have changed occupancy classification. All work/live units, including any alteration to a work/live unit, shall be required to meet the minimum life-safety standards as set forth in this division and the following requirements: (1) Each work/live unit shall have a kitchen area consisting of a sink and garbage disposal with GFI outlet provided. (2) Each work/live unit shall have sanitation facilities consisting of a toilet, lavatory, shower and/or bathtub. (3) Each work/live unit shall have heating facilities capable of maintaining a room temperature of 70 degrees Fahrenheit at a point of three feet above the floor of the unit. All heating equipment must be approved and listed. (4) Habitable space shall have a dimension of not less than seven feet. (5) Kitchens, hallways and bathrooms shall have a ceiling height of not less than six feet, six inches. (6) The ratio of required disabled accessible or adaptable work/live units shall be as follows: Number of Work/Live Units | Number of Accessible Units 5—12 | 1 13—20 | 2 21 or more | 2 plus 1 for each additional 7 work/live units (o) Modifications which create a life-safety, hazardous condition shall not be authorized by the building official. The building official shall have the power to render interpretations of this division and to adopt and enforce rules and supplemental regulations in order to clarify the application of this division. Such interpretations, rules and regulations shall be in conformance with the intent and purpose of this division.
(Code 1959, § 5-163; Ord. No. 3759, § 1)
Ask a question about Pomona law
Corpus searches the Pomona sections it holds and shows the ones that match, with their citations. Free, no sign-in.
