For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 74-171 — Definitions

Pomona City Code, California (Supp. No. 32: codified through Ordinance No. 4371, adopted June 2, 2026) · Pomona City Code § 74-171

Corpus is an independent public-information project, not the official City of Pomona website. Stable reference: corpuslaw.us/code/53cf240c-fde7-4e6f-b314-c03c9d7b1c15

Sec. 74-171. - Definitions.

(a) For the purpose of this article, certain terms, phrases, words and their derivatives shall be construed as specified in either this article or as specified in the California Building Code or the housing code. (b) The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Building code means the California Building Code. Dangerous building means any building, structure or portion thereof that has any or all of the following conditions or defects, provided that such conditions or defects exist to the extent that the life, health, property or safety of the public or the occupants are endangered: (1) Any door, aisle, passageway, stairway, stair rails, guardrails, or other required means of exit is not of sufficient width or size or is not so arranged as to provide safe and adequate means of exit. (2) The walking surface of any aisle, passageway, stairway, floor or floor covering is so warped, worn, loose, torn or otherwise unsafe as not to provide safe and adequate means of passage. (3) The stress in any structural materials, member or portion thereof, due to all dead and live loads, is more than 1½ times the working stress allowed in the building code for new buildings of similar structure, purpose or location. (4) Any portion thereof has been damaged by fire, earthquake, wind, flood or any other cause to such an extent that the structural strength or stability thereof is materially less than it was before such catastrophe and is less than the minimum requirements of the building code for new buildings of similar structure, purpose or location. (5) Any portion or member or appurtenance thereof is likely to fail or to become detached or dislodged or to collapse and thereby injure persons or damage property. (6) Any portion of a building or any member, appurtenance or ornamentation on the exterior thereof is not of sufficient strength or stability or is not so anchored, attached or fastened in place as to be capable of resisting a wind pressure of one-half of that specified in the building code for new buildings of similar structure, purpose or location without exceeding the working stresses permitted in the building code for such buildings. (7) Any portion thereof has wracked, warped, buckled or settled to such an extent that walls or other structural portions have materially less resistance to winds or earthquake than is required for similar new construction. (8) The building or structure or any portion thereof is likely to partially or completely collapse because of: a. Dilapidation, deterioration or decay; b. Faulty construction; c. The removal, movement or instability of any portion of the ground necessary for the purpose of supporting such building; d. The deterioration, decay or inadequacy of its foundation; or e. Any other cause. (9) For any reason, the building or structure or any portion thereof is manifestly unsafe for the purpose for which it is being used. (10) The exterior walls or other vertical structural members list, lean, or buckle to such an extent that a plumbline passing through the center of gravity does not fall inside the middle one-half of the base. (11) The building or structure, exclusive of the foundation, shows 33 percent or more damage or deterioration of its supporting members or 50 percent damage or deterioration of its nonsupporting members, enclosing walls or coverings. (12) The building or structure has been so damaged by fire, wind, earthquake or flood or has become so dilapidated or deteriorated as to: a. Become an attractive nuisance to children; b. Become a harbor for vagrants or criminals; or c. Enable persons to resort thereto for the purpose of committing unlawful acts. (13) Any building or structure which, whether or not erected in accordance with all applicable laws and ordinances, has in any nonsupporting part, member or portion less than 50 percent or in any supporting part, member or portion less than 66 percent of the (i) strength, (ii) fire-resisting qualities, or (iii) weather-resisting qualities or characteristics required by law for a newly constructed building of like area, height and occupancy in the same location. (14) A building or structure used or intended to be used for dwelling purposes, because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangement or inadequate light, air or sanitation facilities is determined by the building official or the health officer to be unsanitary, unfit for human habitation or in such a condition that it is likely to cause sickness or disease. (15) Any building or structure, because of obsolescence, dilapidated condition, deterioration, damage, inadequate exits, lack of sufficient fire-resistive construction, faulty electric wiring, gas connections, or heating apparatus or other cause is determined by the building official or the fire marshal to be a fire hazard. (16) Any building or structure is in such a condition as to constitute a public nuisance. (17) Any portion of a building or structure remains on a site after the demolition or destruction of the building or structure or any building or structure is abandoned for a period in excess of six months so as to constitute such building or portion thereof an attractive nuisance or hazard to the public.

(Code 1959, §§ 5-8, 5-9; Ord. No. 3227, § 2 (part); Ord. No. 3369, § 1 (part))

Ask a question about Pomona law

Corpus searches the Pomona sections it holds and shows the ones that match, with their citations. Free, no sign-in.