§ 74-316 — Alternative compliance for technical infeasibility
Pomona City Code, California (Supp. No. 32: codified through Ordinance No. 4371, adopted June 2, 2026) · Pomona City Code § 74-316
Corpus is an independent public-information project, not the official City of Pomona website. Stable reference: corpuslaw.us/code/5dc25b5b-5313-4b65-8472-dc2acff2a8bf
Sec. 74-316. - Alternative compliance for technical infeasibility.
(a) To demonstrate technical infeasibility, the project applicant shall demonstrate to the city engineer that the project cannot reliably retain 100 percent of the SWQDv on-site, even with the maximum application of green roofs and rainwater harvest and use, and the compliance with the applicable post-construction requirements would be technically infeasible. This shall be demonstrated by submitting a site-specific hydrologic and/or design analysis conducted and endorsed by a registered professional engineer and shall be subject to review and approval by the city engineer. (b) When evaluating the potential for on-site retention, each applicant shall consider the maximum potential for evapotranspiration from green roofs and rainfall harvest and use. Alternative compliance measures include the following: (1) On-site biofiltration. Biofiltration systems shall meet the design specifications provided in Attachment H of the Los Angeles County Municipal Storm Water Permit Order N. R4-2012-0175, and any amendment, revision, or reissuance thereof. If using biofiltration due to demonstrated technical infeasibility, then the new project must biofiltrate 1.5 times the portion of the SWQDv that is not reliably retained on site, as calculated by Equation 1 below: Equation 1: Bv=1.5* [SWQDv-Rv) Where: Bv = Biofiltraton volume SWQDv= the stormwater runoff from a 0.75 inch, 24-hour storm or the 85th percentile storm, whichever is greater Rv=volume reliably retained on-site (2) Off-site infiltration. Use infiltration or bioretention BMPs to intercept a volume of stormwater runoff equal to the SWQDv, less the volume or stormwater runoff reliably retained on-site, at an approved offsite project. The required off-site mitigation volume shall be calculated by Equation 2 below: Equation 2: Mv=1.0*[SWQDv-Rv] Where: Mv=Mitigation Volume SWQDv=Runoff from the 0.75 inch, 24-hour storm event or the 85th percentile storm, whichever is greater Rv=the volume of stormwater runoff reliably retained on-site (3) Offsite project. Retrofit existing development. Use infiltration, bioretention, rainfall harvest and use and/or biofiltration BMPs to retrofit an existing development, with similar land uses as the new development or land uses associated with comparable of higher stormwater runoff event mean concentrations (EMCs) than the new development. The retrofit plan shall be designed and constructed as described in the Los Angeles County Municipal Storm Water Permit Order N. R4-2012-0175, and any amendment, revision, or reissuance thereof. (4) Other alternative compliance requirements are detailed in the Los Angeles County Municipal Stormwater Permit Order No. R4-2012-0175. (c) Applicants and/or designers may select any combination of stormwater BMPs which meet the performance standards provided in this section and identified in the Los Angeles Municipal Storm Water Permit Order N. R4-2012-0175, and the County of Los Angeles Department of Public Works Low Impact Development Standards Manual (February 2014), and any amendment, revision, or reissuance thereof.
(Ord. No. 4185, § 1, 6-2-2014)
Ask a question about Pomona law
Corpus searches the Pomona sections it holds and shows the ones that match, with their citations. Free, no sign-in.