§ 17.120.020: Site design.
A. Grading. Proper grading techniques that are sensitive to natural conditions must be utilized for reasons of public safety, maintenance, aesthetics, and environmental protection. 1. To minimize impacts on existing terrain, the maximum amount of cut (excavation) shall not exceed five feet below the natural grade and the amount of fill shall not exceed three feet above the natural grade. 2. Grade land and landscape in increments of no more than five feet to avoid exposing vast expanses of bared earth at any given time in order to minimize soil erosion. 3. Split pads, built-up foundations, stepped footings, or stem walls shall be used for buildings on lots with an average slope that exceeds eight percent. 4. All graded slopes must be either rounded off or contoured. 5. Driveways. a. The slope of a driveway shall not exceed 15 percent at any point along the length or width of the driveway (except as permitted within the Hillside Overlay Zone). b. The slope of a driveway within 18 feet in front (the side with the garage door) of any garage shall not exceed five percent. B. Building Orientation. Buildings shall be placed in a manner compatible with existing and planned uses and buildings. 1. For sites with more than two primary buildings, buildings must be sited to create plazas or common open space. 2. Building orientation shall provide shelter from seasonal high winds. C. Access and Circulation. Site design must provide safe and efficient paths of travel for vehicles and pedestrians and reduce conflicts between pedestrian and vehicles. 1. Vehicular access. a. On all new development sites within the Wildland-Urban Interface Area, two means of ingress and egress are required. b. Access for both required means of egress shall connect with existing access points (driveways, intersections, or median openings) wherever possible. c. Shared access with adjoining properties shall be provided where feasible. d. All points of access shall be designed in conformance with the applicable city engineering services department and fire district standards and policies. 2. Pedestrian access. a. Pedestrian walkways shall be provided between the primary entries of all buildings and the public sidewalk, on-site pathways/paseos, greenway, or other shared open space. b. Pedestrian walkways shall be direct (straight) as physically/technically possible. c. Pedestrian walkways shall be paved in a manner that is continuous materially and visually distinct from areas for vehicular circulation. d. Pedestrian walkways shall be delineated with landscaping. e. Pedestrian walkways shall include human-scaled, low intensity level lighting that is continuously illuminated between sunset and sunrise. Such lighting may be mounted on poles/posts, embedded in low walls, or in the pavement or ground. When mounted on a vertical structure (pole, post, or wall), the light source shall not be more than three feet above the walkway surface. f. Pedestrian walkways must connect the on-site open spaces with public sidewalks and building entrances. g. For sites with more than two primary buildings, common open spaces, plazas, or courts must be accessible from all corners. FIGURE 17.120.020-1 ACCESSIBILITY OF OPEN SPACES [image] 3. Greenways. a. On-site greenways that link private common areas with public areas such as rights-of-way and multi-purpose trails are required for residential projects and for projects of three acres or more. b. Required greenways shall: i. Provide a continuous connection across the project site. ii. Have a minimum average width of 20 feet but at no point be less than ten feet in width. iii. Have no solid walls or fencing for a minimum of 50 percent of its length. When adjacent to residential properties within a subdivision, gates shall be provided in any wall/fence that separates a lot within the subdivision to allow direct access to the greenway. iv. Provide for equestrian (local feeder trail) use in the Equestrian Overlay Zone. v. Connect to existing or planned greenways located on adjacent properties with no walls/fences or gates inhibiting access between the subject property and adjacent properties. vi. Be recorded as an easement on common property that is privately maintained. 4. Multi-purpose trails. a. All trails ("regional," "community," and "local feeder" as defined in the trails implementation plan) must be constructed according to the city's technical standards related to, for example, surface material, fencing, access gates, drainage, and landscaping. b. Where existing traditional bicycling, pedestrian, equestrian travel routes, and routes to schools exist through a property, trails must preserve the traditional paths where possible. c. All new developments are to be designed in accordance with the Trails Implementation Plan and adopted trail standards as defined in that document. d. Within the Equestrian Overlay Zone, trail connections must be provided through recorded easements in order to connect disconnected (or incomplete) trails segments to the overall trails network and for needed access to recreation facilities/activities. e. Local feeder trails must be provided adjacent, and parallel to the rear (or side) property line of residential lots for equestrian access and related equestrian service (e.g. hay delivery and animal care) access for all residential development within the Equestrian Overlay Zone. f. At least one means of public access to the trails network and one internal loop trail system of local feeder trails must be provided in all residential development within the Equestrian Overlay Zone. g. Corral Areas. i. A corral area with a minimum area of 576 square feet shall be provided in the rear yard of all residential lots in all new residential development within the Equestrian Overlay Zone. ii. This corral area may be rectilinear (24 feet by 24 feet or 12 feet by 48 feet) or circular (27 feet in diameter). iii. This corral area shall be graded flat/level. It is not necessary to provide any physical improvements for the corral area such as fences, posts, etc. iv. Grade access from the corral area to the trail with a maximum slope of five to one (5:1) and a minimum width of ten feet. v. Corral areas must be placed adjacent to the local feeder trail that serves the lot. vi. Lots shall include a gate at the rear or side perimeter from the rear yard to the local feeder trail for use and trail maintenance purposes. D. Parking. The following standards supplement the standards of chapter 17.64 (Parking and Loading Standards). 1. Frontage. The combined frontage of access driveways and parking in the form of surface parking or freestanding garages/carports may occupy: a. A maximum of 40 percent of the frontage of any lot up to 100 feet in width. b. A maximum of 30 percent of the frontage of any lot more than 100 feet in width. FIGURE 17.120.020-2 MAXIMUM PARKING FRONTAGE [image] 2. Parking access. a. A maximum of two driveway aprons for one-way traffic and one driveway apron for two-way traffic may be permitted per street frontage per lot. Lots greater with 400 feet of street frontage or greater may have one additional driveway apron per street frontage. b. Entrances to parking facilities along a block frontage shall be separated by a minimum of 40 feet, excluding access to parking plazas. c. Where possible, driveway aprons serving adjacent parking facilities shall be shared. d. Access to parking for corner parcels shall not be provided from the front of the lot. e. Driveways shall not exceed 16 feet in width through public parkway frontages. Where providing access to fire lane, the drive aisle shall widen to a minimum of 26 feet. f. Access to parking shall be a minimum of 50 feet from the intersection of the front and street-facing side property lines. 3. Parking in single-family residential development. A minimum 50 percent of all the dwelling units within a single-family residential development project shall comply with at least one of the following requirements: a. The garage is detached, and located 20 feet behind, the main dwelling unit. b. The face ("wall" plane) of the garage door is parallel to the side or rear property line of the lot. c. The face ("wall" plane) of the garage door of an attached garage is a minimum of ten feet behind the longest wall plane (measured horizontally) of the main dwelling unit that faces the street / public right-of-way. 4. Freestanding residential garages/carports. a. Drive aisles may not exceed 150 feet in length when garages/carports are aligned; 200 feet when garages/carports are staggered or offset. b. Freestanding garage/carport structures may house up to eight cars side-by-side. c. Each car space within a multiple-space garage or carport structure shall be separated with a solid wall/partition in accordance with the Building Code except where two or more spaces are designated to serve a single dwelling unit. d. For single garage units, the inside dimension shall be a minimum of ten feet by 20 feet. e. All drive aisles shall incorporate the design and technical requirements of the fire district such as minimum aisle width, "hammerhead" turnarounds, fire lane markings, and curbing. f. Garage/carport structures shall have materials, finishes, trim, and colors that match the corresponding elements of the primary building of a multi-family residential development or the main dwelling unit of a single-family residential development. g. Vertical support elements of carport structures shall have a minimum horizontal dimension of six inches. 5. Tuck-under parking. All tuck-under parking shall be in individually secured garages with garage doors. 6. Structured parking. a. Any portion of structured parking levels facing the right-of-way must be screened from view by at least one of the following features: i. Regular "punched" openings designed to resemble windows of habitable space; ii. Trellis or living wall with vertical landscaping; or iii. Custom textured or decorative screening. b. Controlled one-way vehicle ingress/egress for parking facilities (gates, doors, etc.) may not exceed 12 feet in width. Controlled two-way vehicle ingress/egress for parking facilities (gates, doors, etc.) may not exceed 24 feet in width. Exceptions to these maximum width requirements are those deemed necessary for public safety access. c. Parking for residential units shall be separated from parking for nonresidential uses through a controlled fence, gate or other barrier, provided that such controls do not inhibit pedestrian access between these parking areas. 7. Tandem. a. Tandem parking may be used to satisfy the required off-street parking requirement. b. Tandem parking that requires backing out onto a public street is prohibited. 8. Bicycle parking. a. Short-term bicycle parking. Short-term bicycle parking shall be located within 30 feet of a primary building entrance and shall be visible from the primary building entrance. b. Long-term bicycle parking. Long-term bicycle parking must be located on the same lot or property as the use it serves in a parking facility; a dedicated room or building; an enclosed bicycle locker; or a fenced, covered, and locked bicycle storage area. E. Paving. 1. Hardscape materials. On-site hardscape material shall be permeable or pervious and light in col-or with a high solar reflective index. 2. Paving within setback area. Plazas or outdoor seating areas located within street-facing setbacks or private frontage areas must be separated or visually distinguished from the sidewalk by landscaping, raised planters, special paving or similar features. Paving within required setback areas shall be different from that of the adjacent public sidewalk. F. Landscaping. The following standards supplement the standards of chapter 17.56 (Landscaping Standards). 1. Minimum dimension. The minimum dimension of any required landscape area is 30 inches. 2. Existing features. a. Natural features, such as trees and vegetation over ten feet in height, rock outcroppings, and water sources must be maintained and incorporated into the site design. b. Existing, mature trees where the drip-line is outside of the proposed building footprint must be preserved unless it can be demonstrated that other development standards cannot be met. 3. Plant selection. Plants must be selected to reinforce community identity, create a pleasant and livable environment, control erosion, provide protection from wind and hot summer sun, and tie new development into the surrounding context. a. Landscape species must be native, low-water usage, and low maintenance. b. Landscaping must be fire-resistant. In high fire hazard areas, plant material must conform to the fire district's vegetation management codes and standards. c. In the wildland-urban interface fire area, plants, trees, shrubs, and ground covers shall consist of species and spacing in accordance with the fire district's applicable codes and standards. d. Landscaping must be placed according to sunlight needs. e. Plant size at maturity must be considered when planting near property lines, buildings, site features, streets and sidewalks. f. Where a nonresidential development abuts residential property, landscaping in the nonresidential side yard must not exceed the height of the residential structure. g. Trees on southern and western exposures must be deciduous. 4. Prohibited. The following may not count toward required landscaping: a. Plant species that are listed by California Invasive Plan Council (Cal-IPC) as invasive. b. Flammable mulch. 5. On-site drainage. On-site drainage shall be provided using natural drainage channels, bioreten-tion areas, or other landscape areas that filter surface water run-off. 6. Landscape accents. a. Required landscaped areas within the front setback shall include at least one of the follow-ing: i. Specimen trees. ii. Flowering trees or plantings. iii. Decorative rockscape features. iv. Accent pavement or pavers. b. Landscape features are required at all primary building entries. G. Walls and fences. The following standards supplement the standards of chapter 17.48 (Fences, Walls and Screening). 1. For corner side yards of lots in a new residential development, walls/fences shall have a minimum setback of five feet from the interior edge of the sidewalk pavement (or in the absence of a well-walk, the street side property line). 2. On corner side yards of lots in an existing residential development, any new wall/fence where there is not an existing wall/fence must have a minimum setback of five feet from the interior edge of the sidewalk pavement (or in the absence of a sidewalk, the street side property line). 3. On corner side yards of lots in an existing residential development, any new wall/fence where there is an existing wall/fence may be constructed at the setback of the existing wall/fence. 4. New fences in the Wildland-Urban Interface Fire Area shall of non-combustible materials. 5. Retaining walls. a. All retaining walls must be constructed in a stepped or terraced fashion with the maximum height for any single wall no more than four feet, unless physical limitations on the site or structural engineering conditions do not make terracing feasible. If the change in grade is greater than four feet, a series of retaining walls, interspersed by planting areas in a stepped or terraced fashion shall be constructed to minimize its visual prominence and avoid a monolithic appearance. The minimum separation between terraced retaining walls shall be three feet (measured between the nearest vertical surfaces of the walls). b. Retaining walls visible from the public right-of-way are to be constructed of decorative concrete blocks or have a decorative finish. c. Retaining walls shall provide visual interest through the use of form, texture, detailing and planting. When a retaining wall contains an entry stairway to the residence, the design of the wall shall include features that emphasize the entryway. 6. Perimeter fences and walls. Walls enclosing the perimeter of a residential development shall be constructed of decorative CMU such as split-face or fluted block, or CMU with a decorative finish such as stucco or stackstone. H. Refuse and recycling areas. 1. Location. Common refuse (trash), green recycling, and general recycling containers/bins and structures used for the purpose of enclosing such containers/bins shall not be located: a. Within any required street-facing setback; b. In any required parking or landscaped areas; or c. In any other area required to remain unencumbered, according to fire and other applicable building and public safety codes. 2. Container/bin materials. Containers/bins used for the collection and storage of refuse and recyclable materials shall be: a. Constructed of a durable waterproof and rustproof material; b. Covered when the site is not attended; c. Secured from unauthorized entry or removal of material; and d. Of a capacity sufficient to accommodate materials collected between collection schedules. 3. Visibility. Common refuse (trash), green recycling, and general recycling containers/bins shall be screened by enclosures such that no containers/bins are visible from the public right-of-way. a. Enclosure materials may include landscaping, fences or walls. b. Constructed enclosures must be durable, waterproof and rustproof. 4. Clear zone. The area in front of and surrounding all enclosure types shall be kept clear of obstructions and accessible. 5. Drainage. The floor of the enclosure shall have a drain that connects to the sanitary sewer system. I. Fire Safety. Areas designated as high fire hazard areas must provide vegetation management and landscaping in accordance with the fire district's codes and standards.
( Ord. No. 1000 § 4, 2022 )
Ask a question about Rancho Cucamonga law
Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.