§ 17.130.050 — Specific to Zones
Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 17.130.050
Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/70d4bc30-b003-424d-8fff-da6d2a39536a
§ 17.130.050: Specific to Zones.
This section establishes development standards that are specific to each form-based zone. Standards specific to zones include those for density, intensity, frontage area, overall building height, ground floor height, and surface parking setbacks. Development may be further limited by building type, as established in Section 17.130.060 (Building Type Standards). [image] Table 17.130.050-1 Required Build-to-Line, Height, and Frontage Area Standard [1] | Form-Based Zones NE2 | NG3 | CE1 | ME1 | ME2 | CO1 | CO2 | CE2 DENSITY AND INTENSITY (MAX.)[4] Dwelling Units per Acre(Du/ac) (min./max.) | 0/8 | 0/24 | 0/30 | 18/30 | 24/42 | 24/42 | 36/60 | 40/10020/50 in subzone Target Nonresidential Floor Area Ratio(FAR) (min./max.) [2] | 0/0.4 | 0.4/0.60.2/0.4 in subzone | 0.2/1 | 0.6/2.0 | 0.4/2.0 | 0.4/1.0 | 0.6/1.5 | 1.0/2.00.2/0.4 in subzone BUILD-TO LINES A | Primary Build-to Line(max./min.) | 40 ft./NA | 5 ft./15 ft. | 0 ft./10 ft. | 5 ft./20 ft. | 5 ft./15 ft. | 0 ft./15 ft. | 0 ft./15 ft. | 0 ft./10 ft. B | Secondary Build-to Line(max./min.) | 30 ft./NA | 5 ft./15 ft. | 0 ft./10 ft. | 5 ft./20 ft. | 5 ft./15 ft. | 0 ft./15 ft. | 0 ft./15 ft. | 0 ft./10 ft. BUILDING PLACEMENT WITHIN PRIVATE FRONTAGE AREAS C | x 100 | Minimum Built Percentage of Primary Frontage Width | NA | 65% of primary frontage width | 80% of primary frontage width | 70% of primary frontage width | 75% of primary frontage width | 80% of primary frontage width | 85% of primary frontage width | 90% of primary frontage width D E | x 100 | Minimum Built Percentage of Secondary Frontage Width | NA | 30% of secondary frontage width | 30% of secondary frontage width | 30% of secondary frontage width | 30% of secondary frontage width | 30% of secondary frontage width | 30% of secondary frontage width | 40% of secondary frontage width F HEIGHT G | Ground Floor Residential Use (min.) | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. H | Ground Floor Nonresidential Use (min.) | 12 ft. | 12 ft. | 15 ft. | 12 ft. | 12 ft. | 15 ft. | 15 ft. | 15 ft. I | Upper Floor Nonresidential Height (min.) | 9 ft. | 9 ft. | 10 ft. | 10 ft. | 10 ft. | 9 ft. | 9 ft. | 9 ft. J | Residential Finish Floor Elevation above Grade at Max. Build-to Line (min.) | 0 in. 36 in. max. | 30 in. | 30 in. | 30 in. | 30 in. | 30 in. | 30 in. | 30 in. K | Nonresidential Finish Floor Elevation above Grade at Max. Build-to Line (max.) | 18 in. | 18 in. | 18 in. | 12 in. | 12 in. | 12 in. | 12 in. | 12 in. L | Total Stories (max.)[3] | 3 stories | 3 stories | 4 stories | 5 stories | 4 stories | 4 stories | 5 stories If located within a community activity node, fronting Foothill Blvd or Haven Ave., or as approved consistent with Chapter 17.138 (Large Site Development) | | | | | 5 stories | 5 stories | 7 stories | no maximum PARKING SETBACKS (MIN.) M | Surface Parking, Front, or Street Side if located on a Transit Priority Street | 25 ft. from building facade | 30 ft. | 50 ft. | 40 ft. | 40 ft. | 40 ft. | 40 ft. | 50 ft. N | Surface Parking, Street Side (if not located on a Transit Priority Street) | 25 ft. from building facade | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. Notes: 1. | The maximums allowed by zone may not be attainable due to limitations from other standards (e.g., building and design standards) or unique site characteristics, such as lot size, trees, waterways, and steep slopes. 2. | FAR applies to nonresidential portion of the development only, including nonresidential portions of mixed-use development. Ground floor project amenity spaces associated with the on-site residential use (ex. leasing office, community space, gym for residents, child care space, communal work space etc.) shall be limited to a maximum of 30% of the ground floor frontage. 3. | Maximum height in feet determined by building type, see Section 17.130.060. For properties within the Ontario Airport Land Use Compatibility Plan (OALCP), the maximum height is established in the OALCP. The OALCP standard supersedes the maximum height allowed in this article. 4. | Density and FAR are calculated individually. When there are multiple development sites on a single property, individual development sites may deviate from minimum or maximum standards so long as the total site average FAR and Du/AC are within established limits. 5. | All new developments located along Foothill Boulevard and Haven Avenue (south of Church Street and north of Jersey Boulevard) are required to contain ground-floor commercial space fronting onto Foothill Boulevard and Haven Avenue.
( Ord. No. 1000 § 4, 2022 ; Ord. No. 1015 § 3, 2023 ; Ord. No. 1017 § 13, 2023 ; Ord. No. 1023 , 1/17/2024 ; Ord. No. 1053 , 1/21/2026 )
Ask a question about Rancho Cucamonga law
Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.
