For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.138.030 — Site and Block Configurations

Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 17.138.030

Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/c700093d-ff76-44fd-a01f-f7a4c490bcc0

§ 17.138.030: Site and Block Configurations.

A. Block Size. 1. Individual block faces and the total block perimeter shall meet the standards established in Table 17.138.030-1 (Block Size). 2. If a block contains multiple zones, the most intense zone shall be used to establish the requirements for block size. 3. Blocks may be irregularly shaped (i.e., nonrectangular) provided they are still in compliance with the standards in Table 17.138.030-1 (Block Size). 4. Blocks may exceed the maximum allowed face length if a paseo is included, in compliance with Section 17.134.080 (Paseo) and as follows in figures in this section: a. Paseos must cut through the entire block; b. Blocks must comply with maximum perimeter requirements; c. The block face length on either side of the paseo may not exceed the maximum in Table 17.138.030-1 (Block Size); d. The total block face length may not exceed 150 percent of the maximum in Table 17.138.030-1; and e. Maximum one paseo per block. TABLE 17.138.030-1 BLOCK SIZE Zone | Block Face Length (max.) | Perimeter (max.) Neighborhood General 2 (NE2) | 700 ft. | 2,400 ft. Neighborhood General 3 (NG3) | 500 ft. | 1,600 ft. Center 1 (CE1) | 600 ft. | 1,800 ft. Mixed Employment 1 (ME1) | 600 ft. | 1,800 ft. Mixed Employment 2 (ME2) | 600 ft. | 1,800 ft. Corridor 1 (CO1) | 600 ft. | 1,800 ft. Corridor 2 (CO2) | 600 ft. | 1,800 ft. Center 2 (CE2) | 600 ft. | 1,800 ft. B. Thoroughfares. Public or private thoroughfares define the publicly accessible circulation network that refines large sites into more interconnected environments. They provide multiple routes for vehicular, bicycle, and pedestrian circulation. 1. Design. a. Thoroughfares (public or private) must comply with city standards and be designed as public streets. b. Drive aisles not designed as streets do not constitute a thoroughfare and do not satisfy the requirements of this section. c. Thoroughfares within the project must be designed in a manner that is appropriate to their context, with the various elements of the right-of-way (e.g., travel lanes, sidewalk dimensions, etc.) balanced with the land uses and public frontages along the thoroughfare. Therefore, along the length of the thoroughfare, if the context changes, the design of the thoroughfare, especially with regard to pedestrian amenities, must also change. d. All required thoroughfares shall include: i. A landscape buffer between the right-of-way and frontage road; ii. At least one lane of on-street parking, either angled or parallel, that includes a minimum of two EV stations installed per block; iii. A recommended sidewalk width of eight feet minimum; and iv. A recommended lane width of 10 feet minimum. e. The requirements for a frontage road is at the discretion of the Director of Engineering Services. f. The design of proposed new thoroughfares (public or private) shall be reviewed and approved by the Fire Marshal. [image] [image] 2. Multiway/Frontage Road Design. a. Where project sites or development sites exceed 500 feet along any right-of-way, a frontage road is required. b. All required frontage roads shall include: i. A landscape buffer between the right-of way and frontage road; ii. At least one lane of on-street parking, either angled or parallel, that is EV Ready along the length of the frontage road; and iii. A sidewalk a minimum of eight feet in width. If corridor fronting retail or commercial uses are required per Section 17.130.040, the sidewalk minimum shall be 12 feet in width. c. The requirements for a frontage road is at the discretion of the Director of Engineering Services. d. The design of proposed new multiways/frontage roads shall be reviewed and approved by the Fire Marshal. 3. External Connectivity. a. Thoroughfares must be arranged to connect from existing or proposed thoroughfares into adjoining properties whether the adjoining properties are undeveloped and intended for future development, or if the adjoining lands are developed and include opportunities for the connections. b. Thoroughfare rights-of-way must be extended to or located along adjoining property boundaries to provide a roadway connection or thoroughfare stub for development in compliance with the standards in subsection A (Block Size). c. The project site plan must identify all stub streets for thoroughfares and include a notation that all stub streets must connect with future thoroughfares on adjoining property. d. Cul-de-sacs are not allowed. C. [image] Transitions. To facilitate a transition in building height, massing, and scale from corridors to adjacent residential neighborhoods, the following standards apply. 1. For projects with a lot depth 800 feet or greater which share a side or rear lot line with a zone with a lower maximum density or height limit, the following standards apply: a. Single-family adjacent: The maximum height for buildings on development sites which share the lot line is the maximum allowed by the building type or one story above the maximum allowed height of the adjacent zone, whichever is less. b. Multi-family adjacent: The maximum height for buildings on development sites which share the lot line is the maximum allowed by the building type or two stories above the maximum height of the adjacent zone, whichever is less. 2. The height restriction applies to the entirety of the building which is adjacent to the shared lot line. 3. Exemptions. Buildings which are entirely located 60 ft or greater from the shared lot line are not subject to the height restrictions of this subsection. 4. Additional building types that are not permitted in the base zone are allowed subject to a conditional use permit if the proposed building types are determined to be compatible in size and scale to the adjacent lower intensity zone. D. Required Nonresidential Use. 1. Nonresidential uses must occupy a minimum percent of the project building square footage as established in Table 17.138.030-2 (Nonresidential Use Mix). Nonresidential uses provided in compliance with Section 17.130.040(B) (Corridor Fronting Ground Floor Use Restrictions) may count toward the minimum requirement. 2. When in conflict with the ground floor use restrictions in Section 17.130.040(B) (Corridor Fronting Ground Floor Use Restrictions) and/or the minimum FAR standards in Table 17.130.050-1 (Required Build-To-Line, Height, and Frontage Area), the most restrictive standards apply. TABLE 17.138.030-2 NONRESIDENTIAL USE MIX Zone | Minimum Corridor 1 (CO1) | 20% Corridor 2 (CO2) | 20% Center 1 (CE1) | 33% Center 2 (CE2)* | 33% * Does not apply to the Limited subzone

( Ord. No. 1000 § 4, 2022 ; Ord. No. 1015 § 3, 2023 ; Ord. No. 1017 § 16, 2023 ; Ord. No. 1053 , 1/21/2026 )

Ask a question about Rancho Cucamonga law

Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.