§ 17.36.040 — Development standards for industrial zones

Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 17.36.040

Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/99b09a1d-77a0-4f66-aff3-e25e90ae5eba

§ 17.36.040: Development standards for industrial zones.

A. Purpose and applicability. The purpose of this section is to establish minimum development standards that are unique to development projects within the industrial zones. Development standards in this section apply to all land designated on the zoning map within an industrial zone. B. Industrial zones. As identified in chapter 17.26 (Establishment of Zones), the city includes two Industrial Zones: Neo-Industrial (NI), and Industrial Employment (IE). C. Industrial site development standards. General site development standards for industrial zones are listed in Table 17.36.040-1 (Development Standards for Industrial Zones). These development standards supplement the development standards in article IV (Site Development Provisions) that apply to all zones (e.g., parking, signs, landscaping, and lighting). TABLE 17.36.040-1 DEVELOPMENT STANDARDS FOR INDUSTRIAL ZONES Development Standard/Zone | NI | IE Lot area (minimum) (1) | 0.5 ac | 5 ac or 2 ac (2) Lot width (minimum) (3) | 100 ft | 100 ft Min. Setback (ft.) (4) Front yard (and Street Side Yard) | See Table 17.36.040-2 Major Arterial and Special Boulevard | 45 ft | 45 ft Secondary | 35 ft | 35 ft Local/Collector | 25 ft | 25 ft Interior Side yard | 5 ft (5) | 5 ft (5) Rear yard | 0 ft (5) | 0 ft (5) Distance Between Buildings Primary buildings | Must meet current building code requirements Accessory buildings | Must meet current building code requirements Max. Building Height (ft.) Primary buildings (7) | 35 feet at the front setback line (6) 45 ft | 65 ft Accessory buildings—Detached | 25 ft | 25 ft Accessory buildings—Attached Maker Space | 35 ft | 35 ft Max. Floor Area Ratio (Ratio of building floor area to lot square footage) Floor area ratio | 0.6 (8) | 0.6 (9) Max. Building Footprint (sq. ft.) Primary Building (10) | 200,000 | 450,000 Accessory Building—Detached | 5,000 | 10,000 Accessory Building—Attached Maker Space | 30,000 | 30,000 Min. Open Space (minimum percentage of open space per parcel or project) Open space/landscape area | 10%(11) | 10% (2) (11)/5%(11) Performance standards (see Chapter 17.66) | A/B | B/C (2) Table notes: (1) | Condominium lots. Condominium lots and lots within an approved master planned development are exempt from required minimum parcel size and dimension requirements. (2) | The following applies within 1,000 feet of Arrow Route: minimum 2-acre lot area; 10% minimum landscape area; and the "B" level performance standards (chapter 17.66). (3) | Setbacks shall be the minimum required under the city's currently adopted building code. (4) | Setback shall be increased to 45 feet when abutting a residential property line or adjacent to Interstate 15. (5) | See Table 17.36.040-2 for parcels abutting special boulevards as indicated in Figure 17.36.040-1 (Special Streetscape Requirements). (6) | Buildings used for industrial uses that exceed 35 feet in height shall be set back an additional one foot from the front setback line for each one foot of building height up to a maximum setback of 70 feet. The portion of the building used for offices are not subject to this requirement. (7) | Heights over 75 feet may be permitted with a conditional use permit. (8) | For hotels and motels, the maximum floor area ratio is 1.0 (100 percent). (9) | Parking structures in the Neo-Industrial (NI) and Industrial Employment (IE) Zones are exempt from floor area ratio requirements. (10) | Conditional use permit approval by the city council is required for all industrial buildings larger than 75,000 square feet in gross floor area. See section 17.20.060 (Conditional use permit). A master plan is required for all industrial buildings larger than 450,000 square feet in gross floor area. (11) | Waterways preserved count towards overall common open space requirements. D. Other miscellaneous industrial development standards. 1. Special streetscape. Future development and redevelopment within industrial areas shall be consistent with the special streetscape standards listed in Table 17.36.040-2 (Streetscape Setback Requirements) and as depicted in Figure 17.36.040-1 (Special Streetscape Requirements). TABLE 17.36.040-2 STREETSCAPE SETBACK REQUIREMENTS Street Type | Average Depth of Landscape (1, 2) | Building Setback (2, 3, 4, 5) | Parking Setback (5) Arterial Roadway/Boulevard | 45 ft | 45 ft | 25 ft Collector Street | 35 ft | 35 ft | 20 ft Bicycle Corridor/Local Street | 25 ft | 25 ft | 15 ft Table notes: (1) | The average depth shall be uninterrupted from the face of curb, except for sidewalks, pedestrian hardscape, plazas and courtyards, and monument signs. (2) | Parcels less than 225 feet in depth from the ultimate curb face on special boulevards are not required to provide an average depth of landscaping or building setback greater than 25 feet or 20% the depth of the property, whichever is greater. (3) | As determined from ultimate face of curb. (4) | Average depth of landscaping must still be provided. (5) | Setback may be increased based on building height. See Table 17.36.040-1. FIGURE 17.36.040-1 SPECIAL STREETSCAPE REQUIREMENTS [image] 2. Accessory maker spaces. Accessory maker spaces are required in or adjacent to all new buildings that exceed 200,000 square feet in gross floor area in the Neo-Industrial (NI) and Industrial Employment (IE) Zones, subject to the following standards: a. A minimum gross floor area of 3,000 square feet and a maximum gross floor area of 30,000 square feet. b. Accessory maker spaces shall face main arterial roads adjacent to the site. c. Maker space building frontages shall include either an at-grade loading area or an above-grade loading area on a terraced entry. 3. Special building height standards. Building height limits shall not exceed the height limits prescribed in the LA/Ontario International Airport Compatibility Plan. For areas within the High Terrain Zone, the building height limit shall be 70 feet. Buildings or structures greater than 70 feet in height within the High Terrain Zone are subject to the ONT-IAC Project Notification Process and require a Federal Aviation Administration (FAA) exception (Obstruction Evaluation - Form 7460). In cases where the LA/Ontario International Airport Compatibility Plan permits heights greater than 70 feet, building height limits shall be limited to maximum of height of 75 feet, unless a conditional use permit is granted permitting heights greater than 75 feet. 4. Special height exceptions for ancillary equipment. Within the Industrial Employment (IE) Zone, height exceptions may be granted for ancillary equipment with special design and landscape considerations as follows: a. Maximum 90 feet with approval of a minor exception with the additional findings that the ancillary equipment is designed in a manner that integrates well within the subject site and existing and/or proposed landscaping will buffer the views of ancillary equipment from designated view corridors. b. Maximum 120 feet with approval of a conditional use permit with the additional findings that the ancillary equipment is designed in a manner that integrates well within the subject site and existing and/or proposed landscaping will buffer the views of ancillary equipment from designated view corridors. 5. Interim uses. Certain industrial properties may be vacant without any immediate plans for site development. In these instances, the properties may be utilized for a defined list of interim uses for a limited time period as specified below. The uses permitted within this section are supplemental to the uses listed in chapter 17.30 (Allowed Land Uses by Base Zone). a. Permitted interim uses include agricultural crops, roadside stands, farmers market, community garden, and private parks and picnic areas. i. Other uses intended to be temporary that are allowed by right on a permanent basis in the associated zone, upon the determination of the planning director. b. Minor use permit required. Prior to the establishment of an interim use, a minor use permit shall be approved. c. Time period. The maximum time period for an interim use is five years. d. Conditions. At a minimum, the conditions should include an agreement between the city and the applicant stipulating timing, installation of permanent improvements and buildings, and/or restoration of the site to its original condition. At the end of five years, the use shall be removed or the site developed in accordance with the full development regulations of any adopted plan. 6. Interim use standards. The following standards shall apply in all industrial areas for interim uses: a. The minimum streetscape and parking setback requirement shall be contiguous with the ultimate right-of-way line, but in no case less than ten feet. b. No minimum landscape coverage requirements are required, except where necessary for screening purposes as determined by the planning director. c. All parking and storage areas shall be paved with slag, crushed aggregate, asphaltic concrete, concrete, or similar materials. The location, number, and design of the parking and storage areas shall be in accordance with code requirements. d. All parking and storage areas, and other interim uses which require screening as determined by the planning director, shall be screened from public view through a combination of landscaping and fencing. Fencing may include a six-foot chain-link fence with slats, masonry or concrete, wood, or decorative metal. Screening must be maintained in good condition at all times. e. Landscaping required for screening purposes shall include 15-gallon trees and five-gallon shrubs to provide a dense landscape buffer to afford maximum screening from the public view, satisfactory to the planning director. f. Landscaping required for screening purposes shall include 15-gallon trees and five-gallon shrubs to provide a dense landscape buffer to afford maximum screening from the public view, satisfactory to the planning director. 7. Rail service. If rail service is needed for properties which adjoin existing or proposed lead or spur lines, the following rail service access standards, unless modified by the rail service provider or the public utilities commission, shall apply: Rail crossings and any spur construction must be approved by the rail service provider and the public utilities commission. The following rail service standards, unless modified by the railroad or the public utilities commission, shall apply: a. Minimum easement width for a lead line, single track shall be 32 feet. b. Minimum easement width for a double rail track shall be 41 feet. c. The minimum radius of curvature for a track shall be 180 feet. d. The maximum gradient along spur tracks shall not exceed two percent. e. Dock height shall be no less than 4.5 feet above the top of the spur track. f. Road crossings at grade must be avoided wherever possible. g. Spur trackage is not permitted along any frontage between a building and a public right-of-way and must be confined to the side or rear yard area of the building that the rail spur serves. h. Rail loading areas shall be screened from view from the public right-of-way by a wall that matches the architecture, materials, colors, etc. of the building that the rail spur serves. i. Spur tracks shall not encroach onto/across any required parking stalls. Spur tracks shall not encroach across drive aisles for automobile/heavy truck and/or emergency vehicle access except when it is necessary to connect the main rail line with the rail loading area. j. Lot divisions and building layouts for properties which adjoin existing or proposed lead and spur lines shall be done in a manner to ensure full potential of future rail access and use and should not preclude rail access to other properties adjacent to such rail lines. Subdivisions, which could reduce a property's ability to accommodate potential rail served developments, may not be authorized. k. Building design shall include rail service features to ensure the potential use of available spur lines. l. Finished floor elevations and dock height door or "kick out" wall panels shall be provided in all properties abutting rail lines. m. The above-referenced rail service development standards may be amended or deleted on a site-by-site basis during the development review process. The following must be determined by the planning commission in order to authorize any modification of the rail service standard: i. That the installation of a lead or spur track cannot be accomplished due to physical constraints on or adjacent to the project site; and ii. Other existing or potential rail service properties will not be negatively affected in their ability to accommodate rail service activity as a result of modifications to the standards. 8. Equipment screening. The following screening standards shall apply to equipment such as HVAC units, storage tanks, ducting, etc.: a. All roof, wall, and ground mounted equipment shall be screened and not visible from the public right-of-way within the Neo-Industrial (NI) Zone. b. Wherever possible, all roof, wall and ground mounted equipment shall be screened and not visible from the public right-of-way within the Industrial Employment (IE) Zone. c. The visibility of any equipment from the public right-of-way shall be determined by "line-of-sight" and measured from a point that is six feet above the finished surface of the centerline of the public right-of-way, e.g. street. d. All screening of roof mounted equipment shall be accomplished with a parapet wall that is consistent and compatible with the architecture, materials, colors, etc. of the building. Where a parapet wall is not possible, then a screen shall be provided to enclose the roof mounted equipment. This enclosure is exempt from the building height requirement established in Table 17.36.040-1 (Development Standards for Industrial Zones). Where roof mounted mechanical equipment and/or ductwork projects less than 18 inches above the roof or roof parapet it shall be painted consistent with the color scheme of the building. 9. Design standards. The following design standards apply to all new developments in the Neo-Industrial (NI) and Industrial Employment (IE) Zones: a. Site design standards. i. General site design. • | Site elements such as buildings, parking areas, driveways, sidewalks, and outdoor recreational spaces must be arranged to emphasize the aesthetically pleasing components of the site (e.g., landscaping and the superior architectural design of office building element (refer to b. (Building design standards)) and to screen less attractive elements (e.g., service facilities, loading docks, outdoor storage, equipment areas, and refuse enclosures) through the proper placement and design of buildings, screen walls, and landscaping. • | Sites shall have internal sidewalks that connect to sidewalks along public streets to create pedestrian connections. • | Loading dock areas shall be located and designed so that they do not face toward (and are not visible from) any adjacent public right-of-way such as a street. These areas shall be screened with walls or fences and landscaped. See sections 17.48.050(E) and 17.56.060(L). • | All refuse, storage, and equipment areas placed outside of a building shall be screened from adjacent public rights-of-way and uses. ii. Block network parameters for public streets. • | Intersection spacing along arterial edges shall be between ⅛ mile and ¼ mile with at least one mid-block intersection between intersecting arterials and rail, flood control, utility or freeway corridors. • | Intersection spacing inside arterial/arterial blocks bounded by arterials shall be a minimum of 200 feet and a maximum of 1,320 feet. • | Buildings greater than 450,000 sq. ft. in size shall have public streets on at least three sides. • | A minimum of one public street shall run parallel with and within 500 feet of rail (excluding spurs), flood control, utility, or freeway corridors. The parallel street shall run through the block. Street crossings at intersecting corridors shall be established on a case-by-case basis based on feasibility and needs by the city engineer. • | Intersections along arterials shall be aligned with existing/proposed intersections on the opposite side of the arterial where possible and meet minimum design standards for offsets or clearance from adjacent corridors as required by the city engineer. • | Two distinct points of connection shall be provided through an internal block network to the arterial street network for every industrial parcel. iii. Parking location and design. • | Surface parking shall be located to the side or to the rear of principle buildings to the greatest extent feasible. • | Surface parking stalls for employees and guests may incorporate shade structures that are capable of supporting solar/photovoltaic array systems with a minimum clearance height of 12 feet. • | The shade structures shall not encroach into the required access lanes. • | The applicable tree and landscaping standards are not required in the sections of the parking areas where solar arrays systems are placed. See section 17.56.060(L)(2) (Exception for Solar Collectors). • | All new development within the Neo-Industrial (NI) and Industrial Employment (IE) Zones requires a parking management plan, see section 17.64.070 (Parking Management Plan). iv. Open space. • | An outdoor seating/break area is required for every proposed and potential office area of a building. • | On-site open space areas shall contain an outdoor seating/break area with seating designed to allow a variety of sitting environments. • | Outdoor seating areas shall provide shade under a suitable structure and wind protection using landscaping or transparent screening structures. • | Outdoor seating areas shall be easily accessed from the lobby or interior break rooms and placed at the corner of the building or along the side of a building facing a public street. • | Outdoor seating areas are included within the minimum open space requirement in Table 17.36.040-1 (Development Standards for Industrial Zones). v. Landscaping, screening, and street trees. • | All new industrial developments shall adhere to the standards in chapter 17.56 (Landscaping Standards) in addition to the standards provided below. In the event of a conflict, the provisions of this section shall apply. Landscaping shall be provided along the public streets and sidewalks to define the street edge, buffer pedestrians from vehicles, and provide shade. • | All new trees planted within the public right-of-way or to screen the front, side or rear of a building, and to screen the building from Interstate 15 shall be a minimum 24-inch box and planted 25 – 30 feet apart. • | Trees shall be selected and planted to provide shade for walkways, outdoor seating areas, parking areas etc. and for their ability for filtering particulate matter and other pollutants from the air. • | Walls and fences used to provide screening of loading facilities, outdoor trash receptacles, utility equipment, etc. must be solid and designed with materials and finishes that are consistent with and complimentary to the design of the primary buildings. Fences used for security purposes or around parking areas shall consist of wrought iron, tubular steel, or similar material. The use of chain-link is prohibited. Landscape materials as required in accordance with chapter 17.56 (Landscaping Standards) may compliment the requirements for screening, but landscaping without a screen wall or fence does not meet the minimum screening requirement of this section. • | When redevelopment occurs, new public streets as required by the city engineer shall be designed in compliance with the city's Complete Streets policies, public sidewalks along the frontage of the property being developed are required. • | All new sidewalks shall be a minimum of six feet or wider as designated by the city engineer based on existing or planned adjacent land uses to ensure compliance with the city's Complete Streets policies, separated from the curb by a planted parkway, and installed parallel to the property line or curb. Meandering sidewalks along any frontage are prohibited. b. Building design standards. i. Building orientation and placement. • | Buildings shall have articulated and transparent frontages along a minimum of 50 feet on both sides of the building that define the corner. • | Office and administration buildings associated with an industrial use shall be placed at the corner of a building at the intersection of two public streets and/or a main arterial road. The building corner shall have a prominent, vertical structural element (e.g. a tower) that projects no more than 15 feet above the maximum allowable height of the building and that occupies a maximum of five percent of the building roof area. In addition, raised parapets with enhanced decorative treatment such as cornices or crenellations are permitted not to exceed eight feet above the maximum allowable height of the building. If an office or administration building is located at the intersection of two arterial streets the height of the tower or raised parapets may be increased an additional 25 percent. • | The primary entrance to accessory maker spaces and an office/administration building must face the corner or an adjacent main arterial road. • | Where feasible, equipment, electrical, and service rooms shall be placed within the footprint of the building, i.e. inside the building, or screened so that it is not visible from the public right-of-way. ii. Building facade articulation. • | Primary building entries shall be readily identifiable and well-defined using projections, recesses, columns, roof structures, or other design elements. • | All elevations of a building's facade shall include modulation and articulation of the wall plane and roof line, proportionate to the height and length of the building. Exceptions to this requirement are the wall planes at the dock areas and the rear elevation of the building. • | All elevations of a building's facade must have vertical or horizontal variations in color, texture, material, and ornamentation. • | The office component of building facades must contain offset or recessed structural bays, and projecting elements such as colonnades or bay windows. • | Shade elements such as canopies, awnings, arcades, and overhangs shall be provided over all windows, and at all pedestrian entry points, along the front elevation, any street-facing elevation, and office portions of the building. • | Roofs shall be designed as an integral component of building form, mass, and facade, particularly along the front and office portions of the building. Building form shall be enhanced by sloped or offset roof planes, eave heights, and rooflines. iii. Materials and detailing. • | The front and office portions of buildings must be constructed of high-quality materials, including, but not limited to, brick, stone, textured cast stone, tinted masonry units, concrete, glass, and metal siding. • | The following materials are prohibited along the front and office portions of the building: (1) | Unadorned, plain or painted concrete block or panels; (2) | Reflective glass; and (3) | Vinyl, fiberglass, asphalt, or fiberboard siding. • | Where feasible, the industrial/warehousing portion of the building must include a variety of materials and architectural elements to break up the linear planes of these building. Ideally, the building's design and architecture must express the nature of the industrial activity within, in keeping with the other requirements of this section and while respecting the functionality of the use within the building. iv. Door and window openings. • | For office portions of principle buildings, window and door openings must comprise at least 60 percent of the total area of exterior walls facing a public street. • | These windows must be clear or translucent to improve visibility, add visual interest, and allow light into interior spaces. v. Lighting. • | Decorative lighting fixtures shall be provided with a minimum one-foot candle illumination level above that of surrounding parking lots at vehicle driveways and driveway entry/exits, pedestrian pathways, plazas and courtyards, and other activity areas. • | Building and landscape accent up-lighting shall be incorporated into the lighting plan for the development site, with a focus along the front and office portions of the building. • | All exterior lighting shall be shielded to prevent glare and light trespass onto adjacent properties and streets. • | Lighting systems shall be architecturally compatible with surrounding buildings to express the unique character of the area.

( Ord. No. 1000 § 4, 2022 ; Ord. No. 1015 § 3, 2023 )

Ask a question about Rancho Cucamonga law

Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.