§ 17.64.100 — Loading area requirements
Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 17.64.100
Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/5ccd16c7-6201-41c6-95d2-954c92b8dfd0
§ 17.64.100: Loading area requirements.
A. Required loading spaces for delivery and distribution. A building, or part thereof, having a floor area of 10,000 square feet or more that is to be occupied by any use requiring the receipt or distribution by vehicles or trucks of material or merchandise must provide at least one off-street loading space, plus one additional such loading space for each additional 40,000 square feet of floor area. The off-street loading space(s) shall be located behind or to the interior side of buildings, and screened from public view. The off-street loading space(s) must be maintained during the existence of the building or use it is required to serve. Truck-maneuvering areas must not encroach into required parking areas, travelways, or street rights-of-way (see Figure 17.64.100-2 (Loading Areas for Delivery)). B. Required loading spaces for customers. Customer loading spaces allow bulky merchandise to be loaded into customers' vehicles. For uses that sell bulky items (furniture, appliances, home improvement sales, etc.), at least two customer loading spaces per business establishment or one customer loading space per 40,000 square feet of floor area, whichever is greater shall be provided. Customer loading spaces shall be located adjacent to the building or to an outdoor sales area where bulky merchandise is stored. Customer loading spaces shall be clearly visible from the main building entry. Directional signage visible from the main entry shall direct customers to these areas. Customer loading spaces shall not be located in such a way that they impede on-site traffic circulation, as determined by the Director of Engineering Services/City Engineer or encroach into designated emergency vehicle/fire access lanes as determined by the fire chief (see Figure 17.64.100-1 (Customer Loading Areas)). C. Required loading spaces for industrial uses. All industrial uses shall provide a minimum of one loading space per proposed loading bay. For every ten loading bays proposed, a minimum of one on-site truck queuing space must be provided. Each on-site truck queuing space shall be a minimum of nine feet in width and 65 feet in length and shall be included on the circulation management plan if required by the approving authority. The truck queuing spaces shall be grouped together in a designated area with clear access to loading bays. The entrance gate to all industrial buildings shall be a minimum of 135 feet from the public right-of-way. Loading spaces shall be located behind or to the interior side of industrial buildings and be screened from public view. Alternative queuing standards less than the minimum required may be considered by the approving authority with a master plan and the development of an approved parking management plan. D. Requirements for off-street loading spaces. 1. Minimum size. Each off-street loading space required by this section must be not less than 12 feet wide, 30 feet long, and 15 feet high, exclusive of driveways for ingress and egress and maneuvering areas. Loading spaces for customers may be 12 feet wide, 26 feet long, and 12 feet high. 2. Driveways for ingress and egress and maneuvering areas. Each off-street loading space required by this section must be provided with driveways for ingress and egress and maneuvering space adequate for trucks, per city standards. 3. Location of loading areas. An off-street loading space (excluding loading spaces for customers) required by this section must not be located closer than 30 feet to any lot or parcel of land in a residential district, unless such off-street loading space is wholly enclosed within a building or on all sides by a wall not less than eight feet in height. Off-street loading spaces shall be located behind or beside buildings and screened from public view with an eight-foot high, solid masonry or other sound-absorbing wall, with landscaping planted between the wall and the right-of-way. 4. Trailer parking required. One parking space for a trailer is required for each loading dock door. The minimum dimensions of a single trailer parking space is 50 feet in length, 14 feet in width, and 14 feet in vertical clearance. Trailer parking spaces shall be located in a designated area located away from the loading bays and paths of travel. All trailer parking areas must be screened according to the provisions of section 17.48.050 (Requirements by Land Use Type) for industrial areas. FIGURE 17.64.100-1 CUSTOMER LOADING AREAS [image] FIGURE 17.64.100-2 LOADING AREAS FOR DELIVERY [image]
( Ord. No. 1000 § 4, 2022 )
Ask a question about Rancho Cucamonga law
Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.
