§ 17.89.020 — Development and design standards
Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 17.89.020
Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/c042298b-2aa1-434e-a48d-7951dac0b915
§ 17.89.020: Development and design standards.
A. Location and Separation Requirements. 1. Separation Requirements. Automobile service stations, including ancillary uses, shall be separated from other automobile service stations by a minimum of 1,000 feet. Separation distance shall be measured in a straight line from the nearest property line of said automobile service stations. a. Automobile service station which exclusively provides alternative fuels shall not be subject to the separation requirements of this section. B. General Development Standards. New and reconstructed automobile service stations shall comply with the following development standards. 1. Minimum Site Area. 40,000 square feet. 2. Maximum Lot Coverage. 40 percent of the total lot size, including the canopy. No more than 20 percent of the total lot area shall be covered by a canopy. 3. Maximum Number of Driveways. No more than two driveways or means of access shall be provided to any one street or highway. No more than 35 percent of the street frontage shall be devoted to curb cuts. Within integrated developments, share access driveways are required. a. Driveways shall not be located closer than 25 feet to the end of a curb corner or a common property line when adjacent to a residential zoning district. The planning director may consider deviations from this requirement due to demonstrated site constraints, subject to compliance with all other applicable development standards. 4. Pump Islands. a. Pump islands shall be set back a minimum of 60 feet from an adjoining parcel which are used, zoned, or designated by the general plan for residential uses, schools, parks, or religious facility to the nearest edge of the pump island. A canopy or roof structure over a pump island may encroach up to 50 feet within this distance. b. Pump islands shall be set back a minimum of 25 feet from any nonresidential property line to the nearest edge of the pump island. A canopy or roof structure over a pump island may encroach up to 15 feet within this distance. c. The pump island shall be situated to provide stacking space for a minimum of two vehicles behind the vehicle parked at the pump closest to any entrance and/or exit driveway. d. At least one pump station shall be accessible to oversize vehicles, including recreational vehicles. 5. Ancillary Equipment/Devices. Ancillary equipment/devices such as air compressors shall not be located in any required building setback area. 6. Parking Requirements. The automobile service station and any ancillary uses shall comply with all applicable standards of chapter 17.64 (Parking and Loading Standards). Where conflict arises between section, the requirements of this subsection shall take precedent. a. Automobile Service Station. Two spaces minimum. Spaces at the pump island do not satisfy this parking standard. Any additional, ancillary uses on the property shall also include the parking requirements listed below. b. Automobile Service Station with a Convenience Store. Five spaces per 1,000 square feet of gross floor area of the convenience store. Up to 50 percent of the pump islands may be counted as parking spaces at a minimum ratio of one space for each pump island. c. Automobile Service Station with Vehicle Service Bay. One space per service bay. d. Automobile Service Station with Restaurant and/or Car Wash. The parking requirement shall be determined by a parking demand study prepared by an independent traffic engineer licensed by the State of California. The study shall be provided by the applicant, at its sole expense. e. A minimum of one loading space and delivery vehicle stacking area shall be located and designed to avoid undue interference with the public use of streets and alleys, drive aisles, automobile parking spaces, or pedestrian paseos. See chapter 17.64 (Parking and Loading Standards). C. Alternative Fuel Stations. 1. A minimum of one alternative fuel stations shall be provided for every four petroleum-based fuel pumps. The alternative fuel stations can be an electric vehicle charging station, compressed natural gas (CNG), hydrogen, or other alternative fuel. a. Existing automobile service stations shall add at least one alternative fuel station when proposing an expansion of the existing operation. 2. A waiting/seating area shall be provided for customers charging an electric vehicle at a designated charging station. 3. Automobile service stations which exclusively provide alternative fuels shall be subject to the requirements of this chapter, with exception to the separation requirements. D. Building Design and Orientation. See chapters 17.130 (Zone and Building Standards) and 17.132 (Building Entrances and Facades) for building design and orientation requirements. E. Lighting. See chapter 17.58 (Outdoor Lighting Standards) for all applicable lighting standards. F. Landscaping. See chapter 17.56 (Landscaping Standards) for all applicable landscaping standards.
( Ord. No. 1017 § 9, 2023 ; Ord. No. 1023 , 1/17/2024 )
Ask a question about Rancho Cucamonga law
Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.