For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.20.260 — Water quality management plan (WQMP)

Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 19.20.260

Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/845ba667-846a-49f7-8a5e-259731bcf9b4

§ 19.20.260: Water quality management plan (WQMP).

Prior to the issuance of any grading or building permit, all qualifying land development/redevelopment projects shall submit and have approved a water quality management plan (WQMP) to the city engineer on a form provided by the city. The WQMP shall identify all best management practices (BMPs) that will be incorporated into the project to control stormwater and non-stormwater pollutants during and after construction and shall be revised as necessary during the life of the project. The WQMP submittal applies to construction projects covered by the NPDES general construction permit as well as construction projects less than five acres. Qualifying development/redevelopment projects include: A. All significant redevelopment projects. For purposes of this subsection A, the term "redevelopment" means the addition or replacement of 5,000 or more square feet of impervious surface on an already developed site subject to the discretionary approval of the permitting jurisdiction. Redevelopment does not include routine maintenance activities that are conducted to maintain original line and grade, hydraulic capacity, original purpose of the facility, or emergency redevelopment activity required to protect public health and safety. Where redevelopment results in an increase of less than 50 percent of the impervious surfaces of a previously existing developed site, and the existing development was not subject to water quality management plan (WQMP) requirements, the numeric sizing criteria discussed in Section 4 of the current version of the San Bernardino County Stormwater Program Technical Guidance Document for Water Quality Management Plans shall apply only to the addition or replacement, and not to the entire developed site. Where redevelopment results in an increase of 50 percent or more of the impervious surfaces of a previously existing developed site, the numeric sizing criteria discussed in Section 4 of the current version of the San Bernardino County Stormwater Program Technical Guidance Document for Water Quality Management Plans shall apply to the entire developed site. B. All new development projects that create 10,000 square feet or more of impervious surface (collectively over the entire development project site), including commercial, industrial, residential housing subdivisions (i.e., detached single-family home subdivisions, multifamily attached subdivisions or townhomes, condominiums, apartments, etc.), mixed-use, and public projects. New development projects include projects on public and private land that fall under the planning and building authority of the permitting jurisdiction. C. New development or significant redevelopment of automotive repair shops (with SIC Codes 5013, 5014, 5541, 7532-7534, 7536-7539) where the project creates, adds and/or replaces 5,000 square feet or more of impervious surface. D. New development or significant redevelopment of restaurants (with SIC Code 5812) where the land area of project is 5,000 square feet or more. E. All hillside developments of 5,000 square feet or more that are located on areas with known erosive soil conditions or where the natural slope is 25 percent or more. F. Developments of 2,500 square feet of impervious surface or more adjacent to (within 200 feet) or discharging directly into environmentally sensitive areas or water bodies listed on the Clean Water Act, section 303(d) list of impaired waters. G. Parking lots of 5,000 square feet or more exposed to stormwater. The term "parking lot" is defined as land area or facility for the temporary parking or storage of motor vehicles. H. New development or significant redevelopment of retail gasoline outlets that are either 5,000 square feet or more, or have a projected average daily traffic of 100 or more vehicles per day. Non-priority/non-category projects may be required by the local jurisdiction to implement applicable site design LID and LIP requirements.

( Code 1980, § 19.20.260 ; Ord. No. 740 , § 1, 2005 ; Ord. No. 870 (Recodification), 2014 )

Ask a question about Rancho Cucamonga law

Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.