§ 15.08.040 — Residential Code

Municipal Code of the City of Rialto, California (Codified through Ordinance No. 1713, passed April 28, 2026. (Supp. No. 39)) · Rialto Municipal Code § 15.08.040

Corpus is an independent public-information project, not the official City of Rialto website. Stable reference: corpuslaw.us/code/2e47b20b-9039-47ae-b014-75aa55a00f45

15.08.040 - Residential Code.

A. Except as provided in this chapter, the city hereby adopts by reference, as if fully set forth herein, the California Residential Code (CRC) 2025 Edition, including Appendix AA, BF, BG, BO, and CI, including any amendments thereto. B. The 2025 California Residential Code (CRC) is hereby amended as follows: [L1, L2, L3, L4] CRC Section R105.2 is revised by deleting exception 2 from the Building list of exceptions. This amendment is made to require permits for fences not over 7 feet high due to local climatic, geological, and topographical conditions. This amendment is necessary to ensure fences meet the structural design requirements due to the seismic activity and high wind speeds. It's also necessary to ensure the fencing material is not combustible to ensure the spread of flying embers do not spread the fire and become a pathway to buildings and structures. [A, L1, L2] CRC Table R301.2 is amended to read as follows: [A, L1, L2] TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load (Lbs/sf) | Winter Design | Subject to damage from | Winter Design Temp | Ice Barrier Underlayment Required | Flood Hazards | Air Freezing Index | Mean Annual Temp Basic Wind Speed (MPH) | Topographic Effects | Special Wind Region | Windborne Debris Zone | Seismic Design Category | Weathering | Frost Line Depth | Termite 7.0 | North of 210 FWY: 120 South of 210 FWY: 96 | Yes: | No | E | Negligible | 12" | Very Heavy | 43 | No | Yes: See FEMA Map | 0 | 60 [L2, L3, L4] CRC Section R902.1 is amended to require Class A roofing north of the 210 freeway. This amendment is made due to local climatic and topographical conditions. This amendment is necessary to prevent and reduce fire spread during a fire event. Due to the proximity to fire prone areas and the risk of spreading embers from high winds, roofs are susceptible to fire spread if not protected with a higher fire rated roof material. Requiring a higher fire rated roof material will limit the spread of fire. This amendment reads as follows: Roof decks shall be covered with materials as set forth in Section R904 or with roof coverings as set forth in Section R905. A minimum Class A roofing shall be installed North of the 210 freeway. A minimum Class A, B or C roofing shall be installed South of the 210 freeway or where the edge of the roof deck is less than 3 feet (914 mm) from a lot line. Where Class A, B or C roof assemblies are required, they shall be tested in accordance with ASTM E1 08 or UL 790. Where required, the roof assembly shall be listed and identified as to class by an approved testing agency. [A, L3] CRC Appendix CI 100.1 Renovations and Additions is added to read as follows: For properties that have an existing pool without a fence and gate, or drowning prevention features that fail to meet current building code, but renovate the pool, add an ADU, JADU, new primary dwelling unit, addition to the property, major alteration or any combination thereof to the property, the fence and gate, and drowning prevention features shall be required to install a fence and gate and drowning prevention features that meet the requirements in Appendix CI. These most provisions may be required at any time during the review of the application, plan check, or inspection.

(Ord. No. 1702, § 2, 9-9-25)

Ask a question about Rialto law

Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.