§ 18.112.050 — Development standards
Municipal Code of the City of Rialto, California (Codified through Ordinance No. 1713, passed April 28, 2026. (Supp. No. 39)) · Rialto Municipal Code § 18.112.050
Corpus is an independent public-information project, not the official City of Rialto website. Stable reference: corpuslaw.us/code/f961f1de-3b4a-48f0-8419-7547daaa8442
18.112.050 - Development standards.
A. The development standards contained within this section shall apply to all indoor storage facilities, including, but not limited to, storage warehouses, logistics facilities, and fulfillment centers, unless specified otherwise herein. B. General Standards. 1. All indoor storage facilities shall comply with all applicable provisions of Chapter 18.61 of the Rialto Municipal Code. 2. An operations and truck route plan shall be submitted for review and approval as part of the conditional development permit application. The plan shall describe the operational characteristics of the proposed use, including but not limited to, hours of operation, number of employees, types of items to be stored within the building, and the proposed truck routing to and from the facility to designated truck routes that avoids passing sensitive receptors, educational uses, park and open space intended for public park uses, and recreational use intended for public park and recreational use areas to the greatest extent feasible. The plan shall also include physical and operational measures for preventing truck queuing, stopping, and parking on public streets, such as signage and pavement markings, queuing analysis, and enforcement, for preventing truck queuing, circling, stopping, and parking on public streets. Speculative projects for which no tenant is identified shall assume realistic operational characteristics and truck routing upon which any entitlement that is granted shall be based. The operations and truck route plan shall provide that the operator of the indoor storage facility is responsible for enforcement of the operations and truck route plan. Further, a revised operations and truck route plan shall be submitted to and approved by the Community Development Director, or his or her designee, prior to a business license being issued by the city for any new tenant of the indoor storage facility. The Community Development Director, or his or her designee, shall have discretion to determine if changes to the operations and truck route plan are necessary, including, but not limited to, any additional measures to alleviate truck routing and parking issues that may arise during the life of the indoor storage facility. 3. A property maintenance program shall be submitted for review and approval as part of the conditional development permit application. The program shall provide for the regular maintenance of building structures, landscaping, and paved surfaces in good physical condition and appearance. The methods and maximum intervals for maintenance of each component shall be specified in the program. 4. All new or expanded indoor storage facilities less than two hundred fifty thousand square feet in size where the loading bay is within nine hundred feet of a sensitive receptor that is utilizing a site zoned for industrial use shall comply with and incorporate all of the following: a. Orient the truck loading bays on the opposite side of the indoor storage facility away from sensitive receptors to the extent feasible. b. Locate the truck entry, exit, and internal circulation away from sensitive receptors. Heavy-duty truck drive-aisles shall be prohibited from being used on the sides of the building that are directly adjacent to a sensitive receptor property line. c. Any new indoor storage facility within nine hundred feet of a sensitive receptor shall provide a buffer area between sensitive receptors to mitigate light and noise as follows: i. The buffer area shall have a minimum width of fifty feet as measured from the property line of all adjacent sensitive receptors; ii. The buffer area shall include a solid decorative wall, landscaped berm and wall, or landscaped berm ten feet or more in height, drought tolerant natural ground landscaping with proper irrigation, and solid-screen buffering trees; and iii. Trees shall be used as part of a solid-screen buffering treatment and planted in two rows along the length of the property line adjacent to the sensitive receptor. Trees used for this purpose shall be evergreen, broad-leaf, drought tolerant, composed of species with low biogenic emissions, of a minimum thirty-six-inch box size at planting, and spaced at no greater than thirty feet on center. This does not include palm tree species. iv. A public street right-of-way, another development, and/or parcels of land with a minimum width of fifty feet may constitute the buffer area. d. Meet or exceed all requirements of the most current building energy efficiency standards, including, but not limited to, the following requirements related to: i. Photovoltaic system installation and associated battery storage; ii. Cool roofing; iii. Medium- and heavy-duty vehicle charging readiness; and iv. Light-duty electric vehicle charging readiness and installed charging stations. e. Provide conduits at loading bays equal to one truck per every loading bay serving cold storage. Idling or use of auxiliary truck engine power to power climate control equipment shall be prohibited if the truck is capable of plugging in at the loading bay. f. Ensure that any heating, ventilation, and air-conditioning is high-efficiency. g. Provide separate entrances for heavy-duty trucks accessible via a truck route, arterial road, major thoroughfare, or a local road that predominantly serves commercial oriented uses. 5. All new or expanded indoor storage facilities two hundred fifty thousand square feet or more in size where the loading bay is within nine hundred feet of a sensitive receptor that is utilizing a site zoned for industrial use shall comply with and incorporate all of the following: a. Tier 1 — 21 st Century Warehouse Design elements. b. Orient the truck loading bays on the opposite side of the indoor storage facility away from sensitive receptors to the extent feasible. c. Locate the truck loading bays a minimum of three hundred feet from the property line of the nearest sensitive receptor to the nearest truck loading bay opening using a direct straight-line method. d. Provide separate entrances for heavy-duty trucks accessible via a truck route, arterial road, major thoroughfare, or a local road that predominantly serves commercial oriented uses. e. Locate truck entry, exit, and internal circulation away from sensitive receptors. f. Heavy-duty diesel truck drive aisles shall be prohibited from being used on sides of the building that are directly adjacent to a sensitive receptor property line. g. Any new indoor storage facility within nine hundred feet of a sensitive receptor shall provide a buffer area between sensitive receptors to mitigate light and noise as follows: i. The buffer area shall have a minimum width of fifty feet as measured from the property line of all adjacent sensitive receptors; ii. The buffer area shall include a solid decorative wall, landscaped berm and wall, or landscaped berm ten feet or more in height, drought tolerant natural ground landscaping with proper irrigation, and solid-screen buffering trees; iii. Trees shall be used as part of a solid-screen buffering treatment and planted in two rows along the length of the property line adjacent to the sensitive receptor. Trees used for this purpose shall be evergreen, broad-leaf, drought tolerant, composed of species with low biogenic emissions, of a minimum thirty-six-inch box size at planting, and spaced at no greater than thirty feet on center. This does not include palm tree species; iv. A public street right-of-way, another development, and/or parcels of land with a minimum width of fifty feet may constitute the buffer area. 6. All new or expanded indoor storage facilities where the loading bay is within nine hundred feet of a sensitive receptor, and on land that is not currently zoned for indoor storage facility uses, whether developed or undeveloped, and that needs to be rezoned, shall meet all of the following: a. Indoor storage facilities two hundred fifty thousand square feet or more in size shall incorporate all Tier 1 — 21 st Century Warehouse Design elements. b. Indoor storage facilities less than two hundred fifty thousand square feet in size shall incorporate all 21 st Century Warehouse Design elements. c. Orient the truck loading bays on the opposite side of the indoor storage facility away from sensitive receptors to the extent feasible. d. Locate the truck loading bays a minimum of five hundred feet from the property line of the nearest sensitive receptor to the nearest truck loading bay opening using a direct straight-line method. e. Provide separate entrances for heavy-duty trucks accessible via a truck route, arterial road, major thoroughfare, or a local road that predominantly serves commercial oriented uses. f. Locate truck entry, exit, and internal circulation away from sensitive receptors. g. Heavy-duty diesel truck drive aisles shall be prohibited from being used on sides of the building that are directly adjacent to a sensitive receptor property line. h. Any new indoor storage facility within nine hundred feet of a sensitive receptor shall provide a buffer area between sensitive receptors to mitigate light and noise as follows: i. The buffer area shall have a minimum width of one hundred feet as measured from the property line of all adjacent sensitive receptors; ii. The buffer area shall include a solid decorative wall, landscaped berm and wall, or landscaped berm ten feet or more in height, drought tolerant natural ground landscaping with proper irrigation, and solid-screen buffering trees iii. Trees shall be used as part of a solid-screen buffering treatment and planted in two rows along the length of the property line adjacent to the sensitive receptor. Trees used for this purpose shall be evergreen, broad-leaf, drought tolerant, composed of species with low biogenic emissions, of a minimum thirty-six-inch box size at planting, and spaced at no greater than thirty feet on center. This does not include palm tree species. iv. A public street right-of-way, another development, and/or parcels of land with a minimum width of one hunred feet may constitute the buffer area. 7. All new or expanded indoor storage facilities shall provide a two-to-one replacement of any demolished housing unit that was on site and occupied within the last ten years, unless the housing unit was declared substandard by the Chief Building Official, pursuant to Health and Safety CodeSection 17920.3, prior to purchase by the developer. For each housing unit demolished, regardless of market value of the unit, two units of affordable housing for people and families of low or moderate income, as defined in California Health and Safety Code Section 50093, that are deed-restricted shall be built within the jurisdiction. Funds from any fee imposed for the replacement of demolished housing units shall be placed in a housing-specific set-aside account and shall be used for housing within three years of collection. 8. All new or expanded indoor storage facilities that affect residential dwellings through purchase shall be required to provide any displaced tenant with an amount equivalent to twelve months' rent at the current rate. C. Site and Architectural Design Standards. 1. All buildings and structures shall be setback from a property line along a sensitive receptor as required in Section 18.112.050 B. of the Rialto Municipal Code and from a street frontage by a minimum of one foot for every one foot of building height, but no less than twenty-five feet. Building height means the vertical distance from the finished grade to the highest point of the building along the side of the building facing a street or sensitive receptor. 2. All buildings and structures shall incorporate horizontal wall plane articulation approximately in the form of wall plane projections, recesses, and/or projected masses every one hundred linear feet on all sides. Horizontal wall plane articulation shall have a minimum depth of at least three feet, as measured from the exterior of the main wall plane, and a minimum width of twelve feet. 3. All buildings and structures shall incorporate vertical wall plane articulation in form of wall height variations of at least eighteen inches approximately every one hundred linear feet on all sides. 4. All buildings and structures shall incorporate enhanced architectural treatments on all sides. Enhanced architectural treatments include combinations of accent building materials, windows/spandrel glass, reveals, metal eyebrow accents, cornices, etc. 5. The need for stairwells on elevations facing streets shall be avoided to improve the aesthetics of the building and minimize the height of buildings. 6. Underground stormwater chambers shall be provided to avoid the need for aboveground stormwater basins. As an alternative, aboveground basins may be permitted if the depth of the basin does not require fencing and the basin can be planted with shrubs and groundcover so as to appear as part of the landscaped area on the site. 7. Site improvements to control and direct truck and van traffic in the desired direction on adjacent streets shall be provided, including but not limited to medians, "pork chop" curb returns, and similar measures. 8. Entry gates into an enclosed truck court shall be setback a minimum of seventy feet from any public right-of-way and an additional seventy feet for every twenty loading bays beyond fifty loading bays. D. Parking and Access Standards. 1. Parking shall be provided for indoor storage facilities in accordance with Chapter 18.58 of the Rialto Municipal Code or the applicable specific plan. 2. All passenger vehicle parking lots, drive-aisles, and truck parking areas or truck courts shall be paved with asphalt or concrete, as required by the city engineer. 3. All required passenger vehicle parking spaces shall be separated from any enclosed truck parking area or truck court and shall not require access through any enclosed truck parking area or truck court to reach the parking spaces. 4. Signs shall be installed at all heavy-duty truck exit driveways directing truck drivers to the nearest truck route as indicated in the truck route plan, as described in [California Government Code] Section 65098.4, and in the state highway system. 5. Sufficient space, including, but not limited to, additional overflow areas, shall be provided to accommodate all maneuvering, queuing, stacking, loading, unloading, and parking of vehicles on-site. 6. On-site electric hook-ups shall be provided to eliminate idling of main and auxiliary engines during loading and unloading of cargo. 7. Anti-idling signs indicating a three-minute heavy-duty truck engine idling restriction shall be posted at indoor storage facility entrances to the site and at the truck loading bays. E. Screening Standards. 1. All stored items, including, but not limited to, trucks and trailers within truck parking areas and courts, shall be completely screened from public view, including, but not limited to, oblique views, by a combination of buildings and/or solid screen walls of either decorative concrete masonry block or decorative concrete tilt-up walls. Decorative masonry block means tan slumpstone block, tan split-face block, or precision block with a stucco, plaster, or cultured stone finish. Decorative concrete tilt-up wall means concrete with a combination of paint and raised patterns, reveals, and/or trim lines. 2. Screen walls shall not be located within any required front yard or street side yard landscape setback area. 3. All stored items, including, but not limited to, trucks and trailers within truck parking areas, shall not exceed eight feet in height unless a taller wall up to fourteen feet is provided to effectively screen along street frontages. The minimum height of screen walls shall be eight feet and the maximum height shall be fourteen feet. 4. Solid walls surrounding truck parking areas and truck courts that are below the grade of an adjacent street shall be backfilled to a grade level that matches the finished grade level of the adjacent street. 5. Solid walls surrounding truck parking areas and truck courts that either at grade or are above the grade of an adjacent street shall incorporate a berm/slope along the entire length of the wall that ensures that no more than eight feet of the wall is visible from public view. The maximum slope shall not exceed a four to one ratio. 6. Solid walls surrounding truck parking areas and truck courts along street frontages that are visible from public view shall incorporate landscape pockets every seventy linear feet to prevent monotony. The landscape pockets shall have a minimum depth of three feet and a minimum width of twelve feet and shall be located on the exterior side of the wall. 7. Solid walls surrounding truck parking areas and truck courts shall incorporate pilasters every seventy linear feet and at all corners and ends of the wall. 8. Anti-graffiti coating or equivalent measure to prevent graffiti shall be provided for all solid screen walls. F. Landscape Standards. 1. All indoor storage facilities shall have a minimum fifteen-foot deep landscaped setback along all street frontages planted with a combination of trees, shrubs, and groundcover. Parking of motor vehicles is not permitted within the required landscape setback area. 2. All indoor storage facilities shall have a minimum ten-foot deep landscaped setback along interior side and rear property lines planted with a combination of trees, shrubs, and groundcover, except within enclosed truck courts. 3. All indoor storage facilities shall have a minimum ten-foot deep landscape planter at the base of buildings and screening walls that are visible from and face street frontages. Planting within these planters shall consist of a combination of small to medium scale trees, shrubs, and groundcover vegetation to soften the edge of the building or screen wall. 4. Trees shall be planted every thirty linear feet within all landscape planters on-site. Two rows of trees shall be provided within all landscape setbacks adjacent to public streets. A minimum of fifty percent of the trees on-site shall consist of evergreen broadleaf tree species to ensure year-round coverage. 5. Shrubs and groundcover vegetation shall be planted an average of three feet on-center or less, or as recommended for the species. Shrubs and groundcover vegetation species shall be selected and plotted to ensure a layering of landscaping from shorter to taller. G. Security Standards. 1. All indoor storage facilities shall be secured and incorporate exterior security cameras that are connected to the city's enforcement system to the satisfaction of the police chief. 2. All indoor storage facilities shall be illuminated entirely every night, from dusk until dawn, with a minimum of one foot candle across the site. Light fixtures shall be arranged or shield so as not to spill light onto neighboring properties. H. Public Noticing. 1. In addition to the provisions of Chapter 18.66.080, public notice of public hearings for proposed indoor storage facilities shall be mailed to all property owners within a one thousand-foot radius of the project site.
(Ord. No. 1653, § 3, 1-26-21; Ord. No. 1703, § 5, 9-23-25)
Ask a question about Rialto law
Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.
