For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.58.030 — Office, commercial and industrial design standards

Municipal Code of the City of Rialto, California (Codified through Ordinance No. 1713, passed April 28, 2026. (Supp. No. 39)) · Rialto Municipal Code § 18.58.030

Corpus is an independent public-information project, not the official City of Rialto website. Stable reference: corpuslaw.us/code/58454429-1afa-4636-8255-e05d87d1e560

18.58.030 - Office, commercial and industrial design standards.

Design standards in this section establish minimum dimensions and guidelines for the design, construction and maintenance of off-street office, commercial and industrial parking facilities, as follows: A. Standard Stall Size. The minimum dimensions of each stall shall be not less than nine feet wide and twenty feet long and shall have a vertical clearance of not less than eight and one-half feet. B. Handicapped Stall Size. Each parking space for the use of physically handicapped persons shall be not less than fourteen feet wide by twenty feet long, shall have a vertical clearance of not less than eight and one-half feet and shall be located in an area not exceeding a two percent slope. All such spaces shall be located within one hundred feet of a level or ramped building entrance. Ramped entrances shall not exceed an eight-and-thirty-three-hundredths percent slope. Parking spaces for the handicapped shall be signed and restricted for the use of handicapped persons in vehicles displaying handicapped placards or other devices required by state law. C. Aisle Dimensions. Each office, commercial or industrial parking space or facility shall have adequate drive aisles and usable turning and maneuvering areas, in agreement with the standards of Table 18.58.030A. Table 18.58.030A Parking Dimensions (in feet) Parking Angle (in degrees) 45° | 60° | 75° | 90° | parallel 1. Parking stall width parallel to aisle | 12.9 | 10.5 | 9.3 | 9.0 | 24 2. Parking stall depth perpendicular to aisle | 21 | 21 | 20.6 | 20 | 9 3. Drive aisle width | 13 | 18 | 19 | 24 | 12 4. Parking bay width for single-loaded aisles | 34 | 39 | 39.6 | 44 | 21 5. Parking bay width for double-loaded aisles | 55 | 60 | 60.2 | 64 | not permitted D. Paving. All parking areas, loading facilities and drive aisles shall be surfaced and maintained with asphaltic concrete, cement or other permanent impervious surfacing material which is approved by the community development department and is acceptable to the city engineer, and shall be maintained in good order. E. Drainage. All parking and loading facilities shall be graded and provided with permanent stormwater drainage facilities which are approved by the community development department and are acceptable to the city engineer. F. Access. Each parking space shall be accessible from a street or alley. No parking space shall be designed to require a vehicle to back into a street. A parking space may be designed to allow a vehicle to back into an alley, if that the space is set back a minimum of five feet from the alley right-of-way. Alley access for parking shall be approved by the community development department. No parking facility shall be so designed as to require a vehicle to enter a public street in order to progress from one drive aisle to another within the same parking facility. G. Ingress and Egress. The number and location of points of ingress and egress shall be subject to community development director or planning commission approval, as applicable, of the parking facility design. The dimensions of curb cuts shall comply with approved city standards. H. Exterior Lighting. Lighting shall be screened and oriented to avoid glare on adjacent streets and properties and shall provide a minimum of one footcandle of illumination at ground level at any location within the parking facility, excepting at convenience markets, where the standard shall be a minimum of one and one-half footcandles. Light standards shall not exceed fifteen feet in height above finish grade, shall be decorative and in keeping with the architectural theme of the facility served, and shall be located within landscape planter areas as approved by the community development director or planning commission, as applicable. No exterior lighting shall create illumination on adjacent properties more than three and one-half footcandles. I. Noise. Noise levels generated by vehicles and loading or unloading activities in a parking facility, as measured on the facility and at adjoining properties, shall not exceed acceptable standards as defined in the city's noise ordinance. J. Screening. Unenclosed off-street parking facilities shall be screened from view of adjoining residential properties, and may be required to be screened or partially screened from view of public streets or other adjoining nonresidential properties if required by the community development director or planning commission, as applicable. Screening shall be accomplished by using of masonry walls, fences, berms, plantings or other acceptable means. K. Landscaping. Parking lot landscaping in agreement with a landscaping plan prepared by a licensed landscape architect and acceptable to the community development director shall be provided for all office, commercial, industrial developments, as follows: 1. A minimum of ten percent of the required gross off-street parking area shall be landscaped. The parking area shall include access drives, aisles, stalls, maneuvering areas and required landscape setbacks around the perimeter of the parking facility. 2. Where required by the community development director or planning commission, as applicable, landscaped areas shall be annexed into the city of Rialto landscape maintenance district No. 1, as provided by Division 15 of the state Streets and Highways Code and city policy. 3. Landscape materials shall include plants acceptable to the community development director and shall emphasize the use of drought-resistant ground covers, shrubs and trees to the extent feasible. At least one fifteen gallon tree shall be installed and maintained for every five parking stalls in the parking facility. Such trees may be clustered or grouped if approved by the community development director. 4. An irrigation system in agreement with an irrigation plan acceptable to the community development director shall be installed and maintained in working order. 5. Landscaping shall be continuously maintained and replanted as necessary. Landscaped areas shall be kept free of debris and litter. 6. Landscaped areas shall be separated from vehicle parking and circulation areas by concrete curbs not less than six inches in height. L. Safety Features. Safety features in agreement with city standards shall be incorporated into the design of the parking facility, as follows: 1. Safety banners protective curbing, directional markers and signs, striping and other devices as deemed necessary by the city engineer shall be installed. 2. Internal circulation for vehicles and pedestrians shall be designed and maintained in agreement with accepted principles of traffic engineering and traffic safety. M. Parking Structures. Parking structures having two or more stories or levels shall be constructed in accordance with design standards which are approved by the community development director or planning commission, as applicable, and acceptable to the city engineer. N. Tandem Parking. Tandem parking, or the parking of one vehicle behind another in a single file, is prohibited. O. Loading Spaces. 1. Loading Space Dimensions. A loading space shall be no less than ten feet in width, twenty-four feet in length, and shall have a minimum vertical clearance of fourteen feet. 2. Location. A loading space or spaces shall be located on the same or adjoining property as the building or structure to be served by the space or spaces. 3. Markings. A loading space shall be marked, striped, signed and otherwise designated for loading purposes as deemed necessary by the city engineer. 4. Exceptions. In rare and unusual circumstances, an alternative to the off-street loading space requirements may be provided subject to approval and findings by the planning commission that the alternative loading facilities will not significantly increase on-street traffic congestion and will not create a traffic hazard. 5. Space Requirements. Loading space or spaces shall be provided as required in Table 18.58.030B. Table 18.58.030B Loading Space Requirements 1. Retail uses, and all first-floor nonresident uses with gross floor area of less than twenty thousand square feet—One space. 2. Retail uses, and all first-floor non-resident uses with gross floor area greater than twenty thousand square feet—One space for each twenty thousand square feet or fraction thereof. 3. Office buildings and hotels with gross floor area of less than one hundred thousand square feet—Determination to be made by director of development services. 4. Office buildings and hotels with gross floor area greater than one hundred thousand square feet—One space for each one hundred thousand square feet or fraction thereof. 5. Industrial and wholesale uses with gross floor area of less than ten thousand square feet—One space. 6. Industrial and wholesale uses with gross floor area greater than ten thousand square feet—As follows: Minimum spaces: 10,000 to 40,000 sq. ft. | One (1) space 40,000 to 100,000 sq. ft. | Two (2) spaces 100,000 to 160,000 sq. ft. | Three (3) spaces 160,000 to 240,000 sq. ft. | Four (4) spaces 240,000 to 320,000 sq. ft. | Five (5) spaces 320,000 to 400,000 sq. ft. | Six (6) spaces Each 100,000 square feet or fraction thereof above 400,000 sq. ft. | One additional loading space

(Ord. 1234 (part), 1995: Ord. 1057 § 1 (part), 1989) (Ord. No. 1645, § 3, 7-14-20)

Ask a question about Rialto law

Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.