§ 18.61.080 — Building design—Commercial and industrial
Municipal Code of the City of Rialto, California (Codified through Ordinance No. 1713, passed April 28, 2026. (Supp. No. 39)) · Rialto Municipal Code § 18.61.080
Corpus is an independent public-information project, not the official City of Rialto website. Stable reference: corpuslaw.us/code/d942d96f-ae29-40a2-a4c2-9f2e8ca47d96
18.61.080 - Building design—Commercial and industrial.
In addition to Section 18.61.060 of this chapter, the provisions of this section are applicable to commercial and industrial uses. A. Main building entrances shall be well defined. The entrances shall be visually and functionally distinct, pedestrian-oriented and visible from the adjacent street system. This may be achieved by, but not limited to: 1. Recessing the entry; 2. Creating an arcade by the use of bollards and accent materials; 3. Provision of seating areas, by providing lush landscaping in combination with enhanced hardscape materials; and 4. Addition of a compatible entry structure. B. Manager residences, when provided, shall be located in the front of the site. C. In order to avoid long, monotonous building facades and to create diversity, building facades greater than one hundred feet in length, measured horizontally, shall incorporate wall plane projections or recesses having a depth of at least three feet to break up the expansiveness of the exterior. D. The building design shall provide architectural and visual interest. Such design elements shall include but not limited to: 1. Wall articulations such as pop-outs, inserts and etc.; 2. Roof treatments; 3. Roof overhangs; 4. Arcades; 5. Articulated mass and bulk; 6. Courtyards and patios; 7. Towers element; and 8. Recessed doors and window openings. Undesirable design elements shall include but not limited to: a. Large blank, flat walls, b. Flat roofs, c. Square "box-like" buildings, d. Highly reflective surfaces such as metal, e. Exposed pip columns, f. Plywood siding, and g. T-11 plywood siding. E. In order to achieve design harmony and continuity with all buildings on-site, the exterior building design shall be consistent amongst all buildings on-site. F. Facades shall be articulated to reduce the massive scale and the one-dimensional appearance of large buildings and provide visual interest. The overall intent is to encourage a more human scale. G. Facades, exterior walls and entryways shall provide consistent architectural treatment. H. Facades that face streets used by the public or are visible to residential properties shall have a variety of windows, entry areas, awnings or other such features along no less than fifty percent of their horizontal length unless the structural integrity of the building is at stake. I. Facades that do not face a street used by the public shall incorporate a repeating pattern that includes, but not limited to, color change, texture change and material change, each of which shall be integral parts of the building. J. Buildings shall be designed to be viewed from all sides. K. Blank walls and facades shall not be permitted except as required for the structure integrity of the building. L. Buildings shall provide protection for pedestrians from adverse weather conditions and not limited to utilizing overhangs, marquees, and awnings at entrances, along pedestrian pathways, and at transportation waiting areas. M. A decorative trellis, canopy, or other overhang shall be constructed over a drive-thru window and extend across the entire width of the drive-thru aisle. Landscaping shall also be provided. N. Entries shall portray an office image which is integrated into the building design. Building entries accessible to the general public shall be pronounced and easily recognizable. O. Office portion of any industrial building shall be located in the front portion of buildings. P. Service doors shall be recessed and integrated into the overall design of the building. Q. Smaller buildings located within a regional center as a separate building pad shall incorporate into their design structural enhancements similar to the principal building. This would provide visual consistency and a greater sense of place within the center. R. Industrial building shall be constructed of concrete tilt-up or masonry block. Metal buildings shall not be permitted except for heavy industrial users and building additions.
(Ord. 1382 § 1 (part), 2006)
Ask a question about Rialto law
Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.