For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.556.080 — Design and development standards

Riverside Municipal Code (Supp. No. 33: codified through Ordinance No. 7776, enacted June 23, 2026) · Riverside Municipal Code § 19.556.080

Corpus is an independent public-information project, not the official City of Riverside website. Stable reference: corpuslaw.us/code/682d942d-8e19-4973-88c3-607ff492a315

19.556.080 - Design and development standards.

A. All outdoor lighting shall be designed and implemented to mitigate light trespass onto adjacent properties and comply with the following: 1. The correlated color temperature of all outdoor lighting shall be 3,000 Kelvin or less, with tolerance within the ANSI standard C78.377 of LED sources. 2. Shall comply with the California Title 24 California Code of Regulations, Title 24, Parts 1, 2, 6 and 11. 3. Shall comply with Table 19.556.080 A - Lighting Limits for Residential Including Multifamily Properties with Fewer than eight Units or Table 19.556.080 B - Lighting Limits for Nonresidential and Multifamily Residential Properties with eight Units or more. a. Except that, the maximum mounting height of luminaires (above finished grade) shall not apply to fully recessed luminaires. b. Except that, the maximum mounting height for buildings with exterior entrance doors shall be 12 feet above adjacent floor unless recessed into an adjacent ceiling, soffit or overhang. c. Average illumination of a façade or edifice shall not exceed five footcandles (50 lux). 4. Lighting shall be hooded or shielded so as to prevent either the spillage of lumens or reflection into the sky. Outdoor lighting shall be downward facing, except as may be specifically allowed herein. Table 19.556.080 A - Limits for Residential Including Multifamily with Less than eight Units. Restriction | Lighting Zone 0 (Zero) | Lighting Zone 1 (One) | Lighting Zone 2 (Two) | Lighting Zone 3 (Three) Automatic Lighting Controls | Per Title 24 Part 6 Section 150.0(k.) 3. (A).iii. Maximum lumens per fully shielded luminaire | 300 | 1000 | 2000 | 3000 Unshielded and decorative lighting | Prohibited | One per residence, not to exceed 300 lumens per residence | Two per residence, not to exceed 600 lumens per luminaire and 1000 lumens per residence | Three per residence, not to exceed 900 lumens per luminaire and 2000 lumens per residence Maximum mounting height of luminaires (above finished grade) | 8 feet | 12 feet | 12 feet | 25 feet Landscape lighting maximum per luminaire | Prohibited | Downlight only, not to exceed 300 lumens | Downlight and/or shielded uplight, not to exceed 450 lumens | Downlight and/or shielded uplight, not to exceed 600 lumens Landscape lighting maximum lumens per acre | 0 | 6000 | 12000 | 18000 Architectural Floodlighting 1 | Prohibited | Prohibited | 16000 lumens above horizontal plane of light source | 20000 lumens above horizontal plane of light source Maximum allowable light trespass 2 | 0 | 0.1 footcandle (1 lux) | 0.2 footcandle (2 lux) | 0.5 footcandle (5 lux) 1. Lumens represent maximum lumens per site development. Architectural floodlighting must comply with unshielded and decorative lighting restrictions, including maximum number of luminaires and lumens per residence. 2. Allowable light trespass shall be determined based upon the light zone in which the trespass occurs, not from which the light originates. Table 19.556.080 B - Limits for Nonresidential and Multifamily Properties more than eight Units. Restriction | Lighting Zone 0 (Zero) | Lighting Zone 1 (One) | Lighting Zone 2 (Two) | Lighting Zone 3 (Three) Maximum Allowed Lighting Watts | Per Title 24 Part 6 Section 140.7 Automatic Lighting Controls | Per Title 24 Part 6 Section 130.2 for nonresidential properties and for multifamily residential properties of 8 residences or more. Backlight, uplight and glare limits | BUG 0,0,0 only | Per Title 24 Part 11 Section 5.106.8 Unshielded and decorative lighting | Prohibited | Prohibited | Maximum 600 lumens per luminaire, not to exceed 12000 lumens per acre. | Maximum 900 lumens per luminaire, not to exceed 18000 lumens per acre Maximum mounting height of luminaires (above finished grade) | 8 feet | 25 feet Landscape lighting per luminaire | Prohibited | Downlight only, not to exceed 450 lumens | Downlight and/or shielded uplight, not to exceed 600 lumens | Downlight and/or shielded uplight not to exceed 900 lumens Maximum landscape lighting lumens per acre | 0 | 9000 | 12000 | 18000 Architectural Floodlighting 1 | Prohibited | Prohibited | 20000 lumens above horizontal plane of light source | 20000 lumens above horizontal plane of light source Maximum allowable light trespass 2 | 0 | 0.1 footcandle (1 lux) | 0.2 footcandle (2 lux) | 0.5 footcandle (5 lux) 1. Lumens represent maximum lumens per site development. Architectural floodlighting must comply with unshielded and decorative lighting restrictions, including maximum number of luminaires and lumens per residence. 2. Allowable light trespass shall be determined based upon the light zone in which the trespass occurs, not from which the light originates.

(Ord. No. 7701, §§ 35, 36(Exh. D.), 37(Exh. E), 2025; Ord. 7447 § 1(Exh. A), 2018)

Ask a question about Riverside law

Corpus searches the Riverside sections it holds and shows the ones that match, with their citations. Free, no sign-in.