§ 16.16.110: Fire protection systems.

A. Fire Control Room. An approved fire control room shall be provided for all buildings protected by an automatic fire extinguishing system. Fire control rooms shall meet the following requirements: 1. Fire control rooms shall contain only fire system control valves, fire alarm control panels and other related fire system equipment. 2. The location of the fire control room shall be approved by the fire code official. 3. Fire control rooms shall have minimum dimensions of five feet by seven feet. 4. Fire control rooms shall be constructed with a one-hour fire rating. 5. Fire control rooms shall be provided with an exterior access door approved by the fire code official. 6. Durable signage shall be provided on the exterior side of the access door. 7. Storage of materials in fire control rooms is prohibited. B. New Buildings. An approved automatic sprinkler system shall be provided in every new building where the total fire area is 3,600 square feet or greater. C. Passive Purge Sprinkler System. One- and two-family dwellings designed and installed with a sprinkler system in accordance with NFPA 13D shall utilize passage purge on a remote domestic plumbing fixture. D. Building Additions. An approved automatic sprinkler system shall be provided in every existing building, except one- and two-family dwellings, when an addition to the floor area is made increasing the size of the building to 3,600 square feet or greater. E. Design Criteria. Minimum sprinkler systems design requirements are as follows unless otherwise approved by the fire code official: 1. Office buildings shall be designed to Ordinary Hazard Group 1. 2. Mercantile and Storage Occupancies with a ceiling height of up to 20 feet shall be designed to Ordinary Hazard Group 2; with a minimum design area of 3,000 square feet. 3. Mercantile and Storage Occupancies with a ceiling height exceeding 20 feet shall be designed with a minimum sprinkler density of 0.495; with a minimum design area of 2,000 square feet. F. Upright Sprinklers. Upright sprinklers shall be installed in all construction types. Exceptions: 1. The following construction types: Type IA, IB, IIA. 2. In all construction types where the roof-system is exposed and contains no ceiling structure or concealed spaces. 3. Sprinkler systems designed in accordance with NFPA 13D. 4. Sprinkler systems designed in accordance with NFPA 13R. G. Chapter 9, Section 903.4.3 of the California Fire Code, as adopted by the city, is hereby amended to read as follows: 903.4.3 Alarms. One exterior approved audible alarm and visual strobe device, located on the exterior of the building in an approved location, shall be connected to each automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. Visible alarm notification appliances shall not be required except when required by Section 907. A single approved audible alarm and visual strobe device shall be provided in the interior of the building in a normally occupied location within each space, unless otherwise required by the California Fire Code. H. Chapter 9, Section 907.6.6 of the California Fire Code, as adopted by the city, is hereby amended to read as follows: 907.6.6 Monitoring. Fire alarm systems required by this chapter or by the California Building Code shall be monitored by a Central Station Service (UUFX) that is listed in the current edition of the UL Online Certifications Directory unless otherwise required by the California Fire Code. Exceptions: Monitoring by a supervised station is not required for: 1. Single and multi-station smoke alarms required by Section 907.2.11. 2. Smoke detectors in Group I-3 occupancies shall be monitored in accordance with Section 907.2.6.3. 3. Automatic sprinkler systems in one- and two-family dwellings. I. Combination Alarm Systems. Combination fire and burglar alarm systems are not permitted. Exception: Group R-3 and R-3.1. J. Fire-Extinguishing Equipment. Automatic fire-extinguishing systems for the protection of grease removal devices, hoods, duct systems and cooking equipment shall be monitored in accordance with 907.6.6. K. Fire Alarm Control Panel. Buildings requiring a fire alarm system shall be equipped with a single fire alarm control panel unless approved by the Fire Code Official.

( Ord. 6156 § 8, 2019 ; Ord. 6594 § 3, 2022 ; Ord. 6990 , 9/17/2025 ; Ord. 6997 , 10/1/2025 )

Ask a question about Roseville law

Corpus searches the Roseville sections it holds and shows the ones that match, with their citations. Free, no sign-in.