§ 15.11.080 — BUILDING SAFETY ENHANCEMENT AREA BUILDING STANDARDS

San Bernardino Municipal Code (2026 S-2: Local legislation current through Ord. MC-1672, passed 10-7-2026) · San Bernardino Municipal Code § 15.11.080

Corpus is an independent public-information project, not the official City of San Bernardino website. Stable reference: corpuslaw.us/code/7015a128-16a7-4787-9eb4-b22c441c90eb

§ 15.11.080 BUILDING SAFETY ENHANCEMENT AREA BUILDING STANDARDS.

(A) Exterior walls. Exterior walls shall be constructed of non-combustible materials or shall provide the equivalent to a minimum of one-hour fire resistance rated construction on the exterior side. (B) Eaves. Eaves shall be enclosed with a minimum seven-eighths-inch stucco equivalent protection. (C) Exterior glazing. Exterior glazing shall comply with the provisions of the California Building Code and with the following additional requirements: (1) Exterior windows, window walls and glazed doors, and windows within exterior doors, shall be tempered glass, or multi-layered glass panels (dual- or triple-paned), or other assemblies approved by the Building Official. (2) Vinyl window frame assemblies shall be prohibited, except when they have the following characteristics: (a) Frame and sash are comprised of vinyl material with welded corners; (b) Metal reinforcement in the interlock area; (c) Glazed with insulated glass or tempered; (d) Frame and sash profiles are certified in AAMA Lineal Certification Program (verified with either an AAMA product label or Certified Products Directory); (e) Certified and labeled to ANSI/AAMA/NWWDA 101/I.S.2-97 for structural requirements; and (f) Except when needed to meet the requirements of the California Energy Code at Title 24, Part 6 of the Cal. Code of Regulations. (D) Garage doors. Garage doors shall be constructed of noncombustible materials or fire-retardant treated wood. (E) Vents. (1) All vents shall be covered with one-eighths-inch mesh corrosion-resistant metal screen or other approved material that offers equivalent protection. (2) Roof-mounted turbine vents shall not be permitted. (F) Insulation. Paper-faced insulation shall be prohibited in attics or ventilated spaces. (G) Roof covering. All roof covering shall be of non-wood materials with at least a Class A or B fire-retardant rating. The open ends of high-profile tile roofs shall be capped with non-ignitable material to prevent birds’ nests or other combustible material from accumulating. Gutters and downspouts shall be constructed of non-combustible material. (H) Fences. Where wood or vinyl fencing is used, there shall be a minimum of five feet separation between the wood or vinyl fencing and the wall of the nearest structure except on those properties where previous construction occurred pursuant to a previous code. Fencing within the five feet separation area shall be of non-combustible material or one-hour fire-resistance-rated construction. (Ord. MC-1162, passed 1-6-2004; Ord. MC-1163, passed 1-23-2004; Ord. MC-1666, passed 8-5-2026)

Ask a question about San Bernardino law

Corpus searches the San Bernardino sections it holds and shows the ones that match, with their citations. Free, no sign-in.