Table 20.225-1 MU-1 Development Standards Density Residential Minimum | 20.0 Residential Maximum | 30.0 FAR, Minimum | 1 1 FAR, Maximum | 1.75 Unit Size Minimum | 600 sf New Subdivision Lot Size Minimum | 1,500 Building Height Minimum | 2 stories/25 feet Maximum | 4 stories/48 feet Max. Adjacent to R PL | 1 story greater than adjacent development. Not to exceed 48 feet. Ground Floor Height | 15 feet Building Placement Primary Street Pedestrian-Oriented | 2 feet required for 80% of frontage; 7 feet max. for 20% of frontage Secondary Street | 6' required for 60% of frontage; 10' max. for 40% of frontage Tertiary Street | 10 feet required for 60% of frontage; 15 feet max. for 40% of frontage Interior PL | 0 feet Alley PL | 3 feet Allowable Building Frontage Types Primary Street Pedestrian-Oriented | Storefront/Awning Forecourt Facades Facing/Adjacent to Residential | Stoop Porch Facades Facing Greenway or Park | Stoop Porch Along Rail Edge & Transit Station | Storefront/Awning Forecourt Other Locations | Storefront/Awning Forecourt Stoop Porch 1 The minimum FAR may be reduced to .85 upon demonstrated hardship. The Mixed Use 1 (MU-1) Zone is intended to define major corridors and transit-proximate locations as mixed use corridors. The MU-1 Zone should incorporate retail storefronts, urban living, and community destinations in a vertical pedestrian-oriented setting. This Zone promotes variety of commercial, office, civic and residential uses integrated as a cohesive development. These uses may be mixed vertically on separate floors of a building, or horizontally in separate buildings on a single site or adjacent parcels. To maintain a pedestrian scale and orientation, permitted uses on the ground floor are limited to retail and other active uses. The MU-1 Zone is intended to implement and is consistent with the Mixed Use 1 (MU1) land use designation of the General Plan. A. Physical Character. The physical environment is characterized by active pedestrian-oriented ground floor commercial, and office uses at the sidewalk. Housing may occur in upper floors or in portions of the building not adjacent to Rancho Santa Fe Road or San Marcos Boulevard. B. Building Form. Buildings are encouraged to be varied in size, forming a minimum streetwall of two (2) stories and a maximum of four (4) stories. Table 20.225-1 identifies applicable requirements for density, building height, FAR, streetwalls and other standards. C. Building Frontage and Active Use Requirements. Table 20.225-1 identifies building frontage requirements and types that are encouraged within the MU-1 Zone. Pedestrian-oriented ground floor uses are required for eighty percent (80%) of the building frontage along primary street frontage, and facing public open spaces or plazas. Ground floor active uses permitted are identified and required by Section 20.255.110 (Allowable Mixed Use Land Uses and Permit Requirements) and Table 20.225-6, and are encouraged along secondary streets and corners intersecting with primary streets. D. Parking. Parking is provided through a combination of on-street customer spaces, park-once/public parking, and off-street private and residential spaces located behind buildings. Properties with frontages solely along San Marcos Boulevard or Rancho Santa Fe Road shall have secondary street or alley-loaded vehicular access or off-site parking with on-street loading. 1. Parking and loading access is not permitted along San Marcos Boulevard; access shall be limited to the frontage road. 2. Parking and loading from Rancho Santa Fe Road shall be prohibited. [image omitted; see the official code] Figure 20.225-2 MU-1 Development Standard Diagram Setbacks and build-to line standards are required in the identified locations. E. Drive-Through Services. Drive-through service facilities (e.g., restaurant take-out windows, automated teller machines, etc.) are not permitted, except those drive-through uses related to payment of parking fees. [image omitted; see the official code] [image omitted; see the official code] Image 20.225-1 A, B Pedestrian-Oriented Streets MU-1 allows mixed use integration of commercial and residential uses. Active ground floor uses are required along primary streets. Setbacks close to the street create a pedestrian-orientated character. [image omitted; see the official code] Image 20.225-2 Parking Locations Residential parking courts should be located behind buildings and should be well landscaped.
(Ord. No. 2025-1568, § 2(Exh. B), 12-9-2025)
Ask a question about San Marcos law
Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.