§ 20.230.070 — Industrial Building Form/Site Development Standards and Guidelines
Municipal Code of the City of San Marcos, California (Codified through Ordinance No. 2026-1582, enacted September 22, 2026. (Supp. No. 14)) · San Marcos Municipal Code § 20.230.070
Corpus is an independent public-information project, not the official City of San Marcos website. Stable reference: corpuslaw.us/code/af5645ca-66ac-4dbb-9ede-fc169df00e0d
Section 20.230.070 - Industrial Building Form/Site Development Standards and Guidelines
All L-I, B-P, I, and I-2 Zone development applications shall provide evidence, site plans, and building elevations to show that the proposed project complies with the following building form and site development standards. Failure to comply with these standards shall result in the withholding of all required zoning and building permits. Where reference is made to additional standards, those requirements shall be shown on development applications. A. Building Design. 1. Avoid monolithic building forms. Varied roof lines and wall planes shall be used to create architectural interest. 2. Design exteriors to hide undesirable qualities of a proposed use (e.g., storage, ventilation systems). B. Architectural Treatments. 1. Reduce large building volumes to a scale consistent with the existing setting through the use of massing, design, and architectural features/elements. See Section 20.230.070.C (Architectural Features). 2. Define main entryways clearly, and smoothly integrate them with the building and landscaping. 3. Design entries to serve as aesthetic focal points of the building and be inviting to visitors. 4. Create varying patterns of shade, sunlight, and depth through varied wall planes, offsets, or recessed openings in combination with window groupings, recesses, awnings, and shade structures. 5. Treat the exterior of all buildings and structures with consistent architectural treatments and complementary permanently colored materials/treatments throughout the parcel. 6. Enhance the character and scale of the building through the design, shape, and slope of roof forms. Roof colors, where visible to the pedestrian, shall be coordinated with those of surrounding wall planes. 7. Reduce visual prominence of fasteners by using architectural panels, concealed fasteners, or other types of metal wall systems. 8. Reduce visual prominence of downspouts, unless they are used as a legitimate architectural detail, by coating the downspouts to match the wall color or concealing them within the walls. 9. For new structures, additions, expansions, and remodeling, landscaping shall not be used to mask substandard building design. C. Architectural Features. Architectural features are, generally, nonstructural design features that enhance the building elevation and provide massing and height relief. 1. Architectural features are permitted to exceed the maximum building height, consistent with the standards of Tables 20.230-3 and 20.230-4. 2. Massing of architectural features shall be limited to thirty percent (30%) of the linear roof square footage. 3. Architectural features shall enhance the overall design of the building and may include parapet walls, tower elements, unique roof treatments, and similar features; all features shall be architecturally compatible with the primary building's design. D. Materials. 1. Tilt-up concrete shall be designed with varied textures and color blocking. 2. All exterior wall elevations facing any street or street frontage shall integrate architectural enhancements; one hundred percent (100%) usage of tilt-up concrete shall not be permitted. 3. Masonry block with textured surfaces is permitted. 4. Use of architecturally enhancing materials, including glass, is encouraged. Use of a single material (such as one hundred percent (100%) glass) on exterior walls shall be discouraged and subject to Site Development Plan Review. 5. All outside and roof equipment, including overhead, rolling, and service doors, shall be painted or designed to be consistent with the architectural theme of the building. 6. Metal buildings, sheet or corrugated metal, asbestos, and similar materials used on exterior walls are prohibited. See Section 20.400.140 (Metal Buildings) for additional regulations. 7. Architectural features or treatments, including upgraded steel or metal, may be permitted where the metal/steel feature is consistent with the architectural theme and improves the design overall, as approved in Site Development Plan Review. E. Circulation Standards. 1. Ingress and Egress. All ingress and egress shall take place on paved ROWs or paved private easements. Circulation shall be designed to allow for turning around, and allow for proper circulation to prevent backing of vehicles onto streets, to the satisfaction of the City Engineer and Fire Marshal. 2. Driveways. Driveway spacing shall be determined by the City of San Marcos Street Design Criteria standards or its successor. a. Maximum of one (1) driveway for each property abutting the street is allowed, unless otherwise approved by the City Engineer. b. Complexes of two (2) or more buildings sharing access to a public street may be permitted two (2) driveways, as approved by the City Engineer. Shared driveways and reciprocal driveway access configurations are required where possible and feasible. c. Driveways shall be thirty (30) feet wide measured at the property line to properly facilitate all passenger and cargo vehicle movements. Driveway widths based on site configuration shall be approved by the City Engineer during Site Development Plan Review. d. Driveways shall provide a minimum of twenty (20) feet landscaped throat distance measured from the back of the ROW line. This minimum shall be increased as deemed necessary by the Site Development Plan Review process. e. All driveways and site access shall meet City's line-of-sight standards. f. Driveways shall conform to the City's "Radius Type Driveway" standards unless otherwise approved by the City Engineer. 3. Loading Areas. All loading facilities and maneuvering areas shall be on-site and shall comply with the standards of Chapter 20.340 (Off-Street Parking and Loading). F. Equipment Screening. Equipment screening is required for all structures within the Industrial Zones, per the standards of Section 20.400.090 (Equipment Screening). G. Lighting Standards. Appropriate lighting for access and safety is required for all structures within the Industrial Zones, per the standards of Chapter 20.300 (Site Planning and General Development Standards). All lights shall be shielded and directed away from adjacent residential uses.
Ask a question about San Marcos law
Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.