§ 20.280.050 — Transit-Oriented Development Standards
Municipal Code of the City of San Marcos, California (Codified through Ordinance No. 2026-1582, enacted September 22, 2026. (Supp. No. 14)) · San Marcos Municipal Code § 20.280.050
Corpus is an independent public-information project, not the official City of San Marcos website. Stable reference: corpuslaw.us/code/bcffbabf-bc7c-44d8-92a0-6646d31acaa4
Section 20.280.050 - Transit-Oriented Development Standards
The new development, design, construction, or establishment of a transit-oriented housing development project, pursuant to the provisions of this chapter, shall conform to these regulations. Any standard of this chapter shall be modified or waived by the Planning Director to the extent necessary to avoid physically precluding the applicable density, Floor Area Ratio (FAR), or height permitted by Government Code Section 65912.157. A. Density, Height, FAR. A transit-oriented development shall comply with the following standards for density, height, and FAR: Table 20.280-1: Density, Height, & FAR Requirements for Transit-Oriented Development Quarter Mile Radius | Half Mile Radius Density Minimum | 30 du/ac 1 | 30 du/ac 1 Density Maximum | 100 du/ac 2 | 80 du/ac Height Maximum | 65 feet/6 stories 2 | 55 feet/5 stories FAR Maximum | 3.0 2 | 2.5 Unit Size | Each dwelling unit shall contain not less than 600 square feet of net habitable area. The average net habitable area of all dwelling units within a transit-oriented development project shall not exceed 1,750 square feet. These development standards are based on those identified in Government Code Section 65912.157 for Tier 2 transit-oriented development stops. Where state law authorizes greater density, height, or FAR, state law shall control. Footnotes: 1. A development of less than 30 dwelling units per acre (du/ac) would not be a transit-oriented development, pursuant to the provisions of this ordinance. 2. Notwithstanding any other law, a transit-oriented housing development project that meets any of the eligibility criteria under Government Code 65912.157(e) and is immediately adjacent to a transit-oriented development stop shall be eligible for an adjacency intensifier to increase the height limit by an additional 20 feet, the maximum density standard by an additional 40 dwelling units per acre, and the residential floor area ratio by 1 prior to the application of Government Code Section 65915. B. Open Space. A transit-oriented development shall have the following minimum open space requirements: Table 20.280-2: Open Space Requirements for Transit-Oriented Development Common Outdoor Open Space | Equal to at least ten percent (10%) of the gross lot area. Common outdoor open space shall: be designed and maintained for shared use by residents of the development; be open to the sky, except for permitted shade structures, awnings, trellises, canopies, or similar features; consist of at least one 400 square foot area with a minimum single dimension of ten (10) feet; may include courtyards, rooftop decks, plazas, paseos, recreation areas, landscaped areas, and outdoor seating areas; and not include vehicle drive aisles, parking areas, loading areas, or mechanical equipment areas. No more than one-quarter of the common outdoor open space area shall be used exclusively for a pet relief area (i.e., dog park). Common Indoor Open Space | Projects with fewer than 50 units: no indoor common space required. 50-75 units: minimum 500 sq. ft. 75-99 units: minimum 750 sq. ft. 100+ units: minimum 1,000 sq. ft. Required common indoor amenity space may include community rooms, lounges, fitness rooms, coworking areas, recreation rooms, multipurpose rooms, leasing and resident gathering areas, or similar indoor spaces designed for shared resident use. Areas used for building lobbies, leasing offices, storage rooms, mechanical equipment, corridors, or circulation shall not count toward the minimum required common indoor amenity space. Private Open Space | 36 sq. ft., minimum dimension 6 feet required for 50% of all residential units, provided as either a porch, patio, or balcony. Open Space shall be interpreted and applied in a manner that does not physically preclude achievement of the applicable density, height, or floor area ratio otherwise permitted by this chapter. C. Shadow and Solar Access Standards. A transit-oriented development project exceeding 45 feet in height and located adjacent to a residentially zoned property shall incorporate building modulation, upper-story stepbacks, orientation, spacing, façade articulation, or similar design measures to reduce shading impacts on adjacent properties. Development shall not result in a net increase of more than two consecutive hours of shadow on March 21 (spring equinox) between 9:00 am and 3:00 pm on any of the following areas on an adjacent residential property: primary outdoor recreation areas; existing ground-floor habitable room windows located within 20 feet of the shared property line; or solar energy systems protected pursuant to state law. Shadow and Solar Access Standards shall be interpreted and applied in a manner that does not physically preclude achievement of the applicable density, height, or floor area ratio otherwise permitted by this ordinance. D. Building Articulation and Façade Standards. A transit-oriented development project shall incorporate façade articulation and variation in order to reduce the appearance of blank wall planes and building massing. Compliance with this section shall be demonstrated through the following objective standards: 1. Building façades exceeding 40 horizontal feet in length shall incorporate at least two of the following elements at intervals not exceeding 40 feet: a. A change in wall plane of at least 2 feet in depth and 6 feet in width; b. Balconies, recessed balconies, bay windows, or projecting architectural features extending at least 18 inches from the façade; c. A vertical variation in materials, colors, or textures extending at least one story in height; d. Upper-story stepbacks with a minimum depth of 4 feet; e. Covered pedestrian entrances or architectural canopies. 2. Street-facing ground-floor façades located adjacent to a public street shall include transparent windows or doors comprising at least 25 percent of the ground-floor façade area between 2 and 10 feet above adjacent grade. 3. Blank wall areas exceeding 20 feet in horizontal length shall be prohibited along street-facing façades and shall incorporate architectural treatments, public art, green walls, etc. 4. Primary building entrances shall be clearly identifiable through at least one of the following: a. Recessed or projecting entry features; b. Canopies or awnings; c. Enhanced architectural detailing; d. Distinct material or color treatment. 5. Exterior building materials shall include a minimum of two material types or finishes on each street-facing façade. E. Parking and Mobility. A transit-oriented development shall provide the minimum parking and mobility requirements: 1. Automobile Parking. Automobile parking shall be provided in accordance with the applicable provisions of Chapter 20.340, to the extent not preempted or otherwise limited by state law, and in conformance with all applicable provisions of state law, including, but not limited to, Government Code Section 65863.2. 2. Bicycle Parking. a. Long-term bicycle parking shall be provided for residents at a minimum ratio of one (1) secure bicycle parking space per dwelling unit. Required long-term bicycle parking may be provided within dwelling units, within secured bicycle storage rooms, bicycle lockers, controlled-access parking areas, or other secure areas protected from theft and weather. b. Short-term bicycle parking for visitors and the public shall be provided at a minimum ratio of one (1) bicycle parking space per twenty (20) dwelling units, with a minimum of two (2) short-term bicycle parking spaces per development. Required short-term bicycle parking shall be located in a publicly accessible area near a primary pedestrian entrance. c. Developments containing twenty (20) or more dwelling units shall provide electric bicycle charging access for residents. Electric bicycle charging access may include standard electrical outlets, dedicated charging receptacles, or charging stations located within secure long-term bicycle parking areas. d. Bicycle parking areas shall be connected to an accessible pedestrian path of travel and shall be designed to allow convenient access without requiring the use of stairs. F. Accessible Path of Travel. A transit-oriented development project shall provide or be connected to the pedestrian access point of the applicable transit-oriented development stop by an accessible pedestrian path of travel. 1. The accessible pedestrian path of travel shall consist of a continuous, reasonably direct, and barrier-free route complying with applicable accessibility requirements of the California Building Code, the Americans with Disabilities Act, and applicable public right-of-way accessibility standards. The accessible pedestrian path of travel may include, but is not limited to: a. Sidewalks and walkways. b. Curb ramps and driveway crossings. c. Marked or signalized pedestrian crossings. d. Accessible pedestrian signals, where applicable. e. Pedestrian refuge areas, where applicable. f. On-site accessible routes connecting the public sidewalk to primary building entrances. 2. Any on-site improvements and any off-site improvements required as a condition of project approval shall comply with applicable accessibility requirements of the California Building Code and adopted engineering design standards.
(Ord. No. 2026-1580, § 4(Exh. C), 7-14-2026; Ord. No. 2026-1581, Exh. C, 7-28-2026)
Ask a question about San Marcos law
Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.
