For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20.445.030 — General Standards

Municipal Code of the City of San Marcos, California (Codified through Ordinance No. 2026-1582, enacted September 22, 2026. (Supp. No. 14)) · San Marcos Municipal Code § 20.445.030

Corpus is an independent public-information project, not the official City of San Marcos website. Stable reference: corpuslaw.us/code/df41b2d1-a3c1-4a4a-a464-e38262276add

Section 20.445.030 - General Standards

The following provisions and the standards of Table 20.445-1 shall apply to all commercial, industrial, public/institutional, mixed use, and multifamily development in any Zone: A. Adequate Facilities. In all Zones, refuse and recycling containers shall be adequate in capacity, number, and distribution to serve the existing and future occupants in an environment that is free from trash and debris. Recycling bins shall be provided in all locations where refuse bins are provided to enable convenience and ease in the recycling of materials. B. Enclosure. All refuse and recycling materials and collection bins shall be enclosed on four (4) sides unless the materials and bins are stored within a legally approved building. See Figure 20.445-1. 1. A swinging double door as an access gate with locking capabilities shall be included on one (1) side of the enclosure. The enclosure shall be designed with decorative heavy-gauge metal gates with cane bolts on the doors to secure the gates when in the open position. Doors or gates to the enclosure shall be self-closing. 2. Enclosures shall provide walk-in pedestrian access without having to open the main enclosure gate if said facility is larger than ten (10) by fourteen (14) feet in dimension. 3. Enclosures shall be constructed of solid masonry material with decorative exterior surface finish compatible to the main building(s). Split-face concrete block finish is recommended. Brick or tile veneer exterior finish should be avoided. Figure 20.445-1 Refuse and Recycling Enclosure Standards [image omitted; see the official code] 4. No material shall be stacked higher than the enclosure walls/fence. 5. A level reinforced concrete slab shall accommodate the entire structure footprint, extending forty-eight (48) inches in front of the access gates, and shall be constructed at the same level as the existing asphalt. Raised bumper guards shall be installed along the inside walls of the enclosure to prevent the dumpster from contacting the enclosure walls. 6. The enclosure shall have an architecturally compatible solid roof/cover feature, with the design to be approved by the Director. Open roof/covers may be permitted if the dumpsters and recycle bins have closable lids. 7. The access gate shall be painted steel and generally obscuring the view of the enclosure contents. C. Location. Recycling and refuse storage enclosures shall not be located in any required front setback, court, alley, or required landscape or parking space. 1. Enclosures shall not be located closer to the public ROW than the main structure. D. Accessible Design. Each recycling/refuse storage enclosure shall be consistent with Table 20.445-1 and the following standards. All standards shall be evaluated based on site design and circulation, subject to Director review and approval during Site Development Plan Review, if applicable. 1. The overhead clearance is required in all conditions, including at roof lines such as overhanging carports or cantilevered stories. 2. The structure shall contain concrete or asphalt drives of sufficient strength to accommodate 54,000 pounds distributed on ten (10) wheels. 3. The structure shall be designed so that vehicular backing movements into a public ROW are not necessary. Table 20.445-1 Refuse and Recycling Enclosure Standards Development Standard | Commercial/Industrial | Multifamily Design Feature Enclosure Size | 10 feet by 14 feet minimum; adequate per Director approval Enclosure Height | 6 feet | 6 feet Overhead Clearance | 16 feet vertical | 16 feet vertical Driveway Area | 18 feet wide | 18 feet wide Turn-Around (if required) | 36-foot radius | 36-foot radius Building Separation | 5 feet minimum | 5 feet Maximum Distance from Dwelling/Building | 150 feet from main structure | 250 feet from unit entry Setbacks Front PL | Behind front setback of main building/structure Interior PL | 5 feet | 10 feet Residential PL | 10 feet | 10 feet All standards are minimums unless otherwise notes. All standards are dependent on site design and circulation, subject to Director review and approval. PL = property line E. Architectural Compatibility. All recycling and refuse storage areas, including covers and doors, shall be compatible with the architectural treatment of the primary building on the parcel. F. Blank Walls Prohibited. Blank walls are prohibited. Where screening or security walls (excluding fences) are located within ten (10) feet of a public ROW, landscaping shall be provided between the wall and the ROW to a minimum height of forty-two (42) inches to minimize opportunities for crime and unsafe conditions. G. Multifamily Development. Refuse and recycling shall not be stored in balcony or porch spaces. The standards of Section 20.445.030 (General Standards) shall apply to all multifamily development.

Ask a question about San Marcos law

Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.