Sec. 39-29. - Protection of public water supply.
(a) State regulations adopted. The regulations of the State of California related to Drinking Water Supplies, Title 17, as they are now in effect or as they may be amended in the future, insofar as the same are applicable to the protection of the water supply of this city, are hereby adopted, incorporated herein and made a part hereof. (b) Purpose; applicability. (1) The purpose of this section is: (A) To protect the public water supply against actual or potential cross-connection by isolating within the premises contamination that may occur because of some undiscovered or unauthorized cross-connection on the premises; (B) To eliminate existing connections between drinking water systems and other sources of water that are not approved as safe and potable for human consumption; (C) To eliminate cross-connections between drinking water systems and sources of contamination; and (D) To prevent the making of cross-connections in the future. (2) It is unlawful to make or maintain, for any period of time whatsoever, any cross-connection between plumbing pipes or water fixtures being served with water by the agency and any other source of water supply, or to maintain any sanitary fixture or other appurtenances or fixtures which may cause or allow backflow of water or other substances into the water supply system of the city and/or the service of water pipes or fixtures of any customer of the city. (3) No water service connection to any premises of a type specified in subsection (i) shall be installed or maintained unless the public water supply is protected as required by applicable state regulations and this section. (c) Approval. (1) Each backflow preventer required hereunder shall be approved by the agency prior to installation and shall be installed by and at the expense of the customer for continued service or before a new service will be granted. (2) The agency shall approve a device when the device has received approval by the Foundation for Cross-Connection Control and Hydraulic Research of the University of Southern California (or other qualified organization as designated by the agency), and will provide desired service and reliability. The agency shall provide, upon request, to any affected customer, a list of approved devices. (d) Installation. (1) Devices shall be installed as close as practical to the customer's service connection and shall be installed above grade in an accessible location approved by the agency. (2) Devices shall have at least the same cross-sectional area as the water meter. In those instances where it is determined that a continuous water supply is necessary, two (2) sets of devices shall be installed in parallel. Where parallel devices are required, the sum of the cross-sectional areas of the devices shall be at least equivalent to the cross-sectional area of the meter. (e) Maintenance, testing, and records. (1) The customer shall test and service such devices at least once a year and immediately after installation, relocation, or repair. A report, in a form acceptable to the agency, which sets forth the results of such test(s) shall be filed immediately with the agency. The agency may require a more frequent testing schedule if it is determined to be necessary and all costs shall be borne by the customer. (2) Devices shall be serviced, overhauled or replaced whenever they are found to be defective. All costs of such service, overhaul or replacement, including testing, repair, and maintenance shall be borne by the customer. The agency may require device information, such as location and pictures, to be submitted with the test forms. (3) The agency will supply affected customers with a list of persons acceptable to the agency to test devices. (4) The agency will notify affected customers when annual testing of a device is needed. Failure to notify shall not relieve the customer of the obligation to test and service its devices. (5) Upon the issuance of a third and final notice to test a device, the agency may impose a backflow preventer third-and-final-notice generation fee in an amount established by resolution of the city council. (6) The city reserves the right to hire a private tester to test the device and bill the customer for the cost of the test plus a backflow device testing administrative fee as set by resolution of the city council, which shall be the responsibility of the applicant, if a device has not been maintained and tested within six (6) months, or one hundred eighty (180) days, from the date when the first notice regarding testing was mailed. Reasonable efforts to notify the customer of the impending testing will be made. (f) Backflow prevention device removal. (1) Notification and approval. The agency must be notified and approval must be obtained from the agency before a device is removed. (2) Removal in general. The use of a device may be discontinued and the device removed from service upon presentation of sufficient evidence to the agency to verify that a hazard no longer exists or is not likely to be created in the future. (3) Removal for relocation. A device may be relocated following confirmation by the agency that the relocation will continue to provide the required protection to satisfy installation requirements. A retest will be required, prior to return to service, following the relocation of the device. (4) Temporary removal for repair. A device may be removed for repair or service, provided water use is either discontinued until repair is completed and the device is returned to service, or the service connection is equipped with backflow protection approved by the agency. A retest will be required, prior to return to service, following the repair or service of the device. (5) Temporary removal for replacement. A device may be removed and replaced, provided water use is discontinued until the replacement device is installed. All replacement devices must be approved by the agency prior to being put into service and must be commensurate with the degree of hazard involved. A retest will be required, prior to return to service, following the replacement of the device. (g) Water system survey. (1) Plans and specifications must be submitted to the agency upon request for review of possible cross-connection hazards for new or existing service connections. If it is determined that a device is necessary to protect the public water system, the required device must be installed before service will be provided or continued. (2) The agency may conduct an on-premises inspection or reinspection to evaluate cross-connection hazards. Any customer which cannot or will not allow an on-premises inspection of their piping system shall be required to install the device the agency considers necessary. (h) User supervisor. At each premises where it is necessary in the opinion of the agency, a user supervisor shall be designated by and at the expense of the customer. This user supervisor shall be responsible for the monitoring of the devices and for avoidance of cross-connections. In the event of contamination or pollution of the drinking water system due to a cross-connection on the premises, the agency shall be promptly notified by the user supervisor so that appropriate measures may be taken to overcome the contamination. The customer shall inform the agency of the user supervisor's identity on, as a minimum, an annual basis and whenever a change occurs. (i) Type of protection required. (1) The type of protection that shall be provided to prevent backflow into the approved water supply shall be commensurate with the degree of hazard that exists on the customer's premises. The type of device shall be one (1) of the following: (A) Approved air gap separation (hereinafter "AG"); (B) Approved double check valve assembly (hereinafter "DC"); or (C) Approved reduced pressure principle assembly (hereinafter "RP"). (2) The customer may choose a higher level of protection than required by the agency. The minimum types of backflow protection required to protect the approved water supply at the customer's water connection to premises, with varying degrees of hazard, are provided in Table 1. Situations which are not covered in Table 1 shall be evaluated on a case-by-case basis, and the appropriate backflow protection shall be determined by the agency. (3) In those instances where conditions warrant, the agency may modify the minimum installation herein indicated as appropriate to provide a degree of protection commensurate with the degree of hazard. TABLE 1. TYPE OF BACKFLOW PROTECTION REQUIRED Degree of Hazard | Minimum Type of Backflow Protection 1. | Aircraft and missile plants | RP 2. | Automotive plants | RP 3. | Auxiliary water systems (interconnected) | RP 4. | Auxiliary water systems (not interconnected) | RP 5. | Beverage bottling plants | RP 6. | Boilers | RP 7. | Breweries | RP 8. | Buildings greater than three (3) stories or greater than thirty-four (34) feet in height from curb level | DC 9. | Buildings with two (2) or more service connections (interconnected) | DC 10. | Buildings with house pumps and/or potable water storage tank | DC 11. | Buildings with wastewater pumping and/or treatment plants (not interconnected) | RP 12. | Canneries | RP 13. | Car wash facilities | RP 14. | Centralized heating and air conditioning plants | RP 15. | Chemical plants | RP 16. | Chemically treated potable water systems | RP 17. | Civil works (facilities not subject to city plumbing inspection) | RP 18. | Commercial laundries | RP 19. | Cooling towers | AG 20. | Dairies and cold storage plants | RP 21. | Dye works | RP 22. | Film processing laboratories | RP 23. | Fire protection system with biological or chemical additives | RP 24. | Fire protection system with unapproved auxiliary water supply (not interconnected) | DC 25. | Fire protection system with unapproved auxiliary water supply (interconnected) | RP 26. | Fire protection system with storage tanks or private reservoirs | DC 27. | Fire protection systems with two (2) or more service connections (interconnected) | DC 28. | Food processing plants | RP 29. | High schools and colleges | RP 30. | Holding tank disposal stations | RP 31. | Hospitals (major complexes) | RP 32. | Irrigation systems | RP 33. | Laboratories using toxic materials | RP 34. | Manufacturing, processing, and fabricating plants using toxic materials | RP 35. | Manufacturing, processing, and fabricating plants using nontoxic materials | RP 36. | Medical and dental buildings | RP 37. | Mobile home parks | DC 38. | Motion picture studios | RP 39. | Oil and gas production facilities | RP 40. | Paper and paper production plants | RP 41. | Plating plants | RP 42. | Premises where recycled water is used (not interconnected) | RP 43. | Radioactive materials processing facilities | RP 44. | Restricted, classified, or other closed facilities | RP 45. | Rubber plants | RP 46. | Sand and gravel plants | RP 47. | Sewage and storm drainage facilities | RP 48. | Any premises where there is a repeated history of cross-connections being established or reestablished | RP 49. | Unapproved water systems or private piping systems constructed without the approval of the agency or the city's planning and building agency | AG 50. | Premises where entry is restricted so that inspections for cross connections cannot be made with sufficient frequency or at sufficiently short notice to assure that they do not exist | RP (j) Discontinuance of water service. (1) Service of water to any premises may be discontinued by the agency, after notice, if a device is not installed, tested, and maintained as required by this section, or if any defect is found in an installed device, or it is found that a device has been removed or bypassed, or if unprotected cross-connections exist on the premises, or if the agency determines a hazard or potential hazard exists. Service will not be restored until such conditions or defects are corrected. (2) When the agency encounters water uses that represent a clear and immediate hazard to the potable water supply, the agency shall institute the procedure for discontinuing the city water service. (3) Conditions or water uses that create a basis for refusal to provide or termination of water service shall include, but are not limited to, any of the following items: (A) Refusal to install a required device. (B) Refusal to test a device. (C) Refusal to repair a faulty device. (D) Refusal to replace a faulty device. (E) Direct or indirect connection between the public water system and a sewer line. (F) Unprotected direct or indirect connection between the public water system and a system or equipment containing contaminants. (G) Unprotected direct or indirect connection between the public water system and an auxiliary water system. (H) A situation which presents an immediate health hazard to the public water system. (4) Water service termination procedures shall include the following items: (A) For conditions (3)(A), (3)(B), (3)(C) or (3)(D) of subsection (j) above, the agency will terminate service to a customer's premises after written notice has been sent, specifying the corrective action needed and the time period in which it must be done. If no action is taken within the allowed time period, water service may be terminated. (B) For conditions (3)(E), (3)(F), (3)(G) or (3)(H) of subsection (j) above, the agency will take the following steps: (i) Make a reasonable effort to advise customer of intent to terminate water service. (ii) Terminate water supply and lock service valve. The water service will remain inactive until correction of violations has been approved by the agency. (k) Information requests. Upon request, the agency will provide interested parties with copies of section 39-29, rules and regulations for the testing and maintenance of devices, and such other advice, information, illustrative sketches, drawings and data as may be necessary to familiarize the customers, engineers, architects and others with agency requirements.
(Ord. No. NS-2921, 5, 8-1-17)
Ask a question about Santa Ana law
Corpus searches the Santa Ana sections it holds and shows the ones that match, with their citations. Free, no sign-in.