Front yard: (a) One (1) 24-inch box canopy tree shall be provided for each twenty-five (25) linear feet of front yard (exclusive of driveways). Such trees may be placed in clusters. (b) Six (6) five-gallon size shrubs shall be provided per twenty-five (25) linear feet of front yard (exclusive of driveways). As an alternative, the use of three (3) five-gallon size shrubs and ten (10) one-gallon shrubs is acceptable provided the plant material adds color and variety to the design. (c) The front yard shall be planted in turf or acceptable dry climate ground cover. A ground cover is required in shrub areas and as accents in small pockets. Redwood header boards or similar barriers shall be placed between turf and other plant materials. (d) Berms in the front yard having more than a 4:1 slope shall be planted in ground cover. Turf is not acceptable. (e) When parkway trees are required by the city, they shall be integrated with the onsite landscape plan to ensure proper spacing and species selection. (f) A minimum five-foot wide landscape strip shall be planted and maintained where the off-street parking area abuts any public street, except at approved driveways. Parking area: (g) In parking areas available to parking by the general public, a landscape planter shall be provided for every ten (10) parking spaces. Each planter shall have minimum dimensions of six (6) feet in width and eighteen (18) feet in length including concrete curbing. Each planter shall be bordered on two (2) sides minimum by parking area. The planter strips shall run parallel to the parking spaces and be consistently spaced throughout the parking area. Each planter shall require one (1) 15-gallon size tree, five (5) five-gallon shrubs plus ground cover. (h) In lots that are solely used by employees of the company, a landscape planter shall be provided for every five (5) consecutive parking spaces. Each planter shall have minimal dimension of four (4) feet by four (4) feet, including concrete curb. Each planter shall require one (1) 15-gallon size tree and a suitable ground cover or low growing shrubs. These planters may be located between parking spaces so as to maximize the amount of available space for parking. Planters may also be consistent with general parking landscape requirements. Each parking area shall be enclosed by perimeter planters abutting the lot or parking spaces, except for the driveways. (i) The choice of plant material shall be trees and/or shrubs, with a ground cover in keeping with the size and limitations of the area. Ground covers alone are not acceptable. A minimum of one (1) 15-gallon tree shall be provided for each ten (10) parking spaces, or portion thereof. (j) Parking areas shall be designed so that parked vehicles shall not encroach into landscape areas. Buffer: (k) A landscaped planter of a width not less than ten (10) feet is required along any interior lot line to the extent such lot line abuts any property which is neither zoned for industrial uses, nor indicated on the general plan of the city as planned for industrial purposes. General: (l) A plant list shall be shown on the required plot plan to obtain a building permit for the building for which the parking area is provided. The list shall include the botanical and common names of the plant to be used, the sizes to be planted, and the quantity of each. The plants shall be listed alphabetically and assigned key numbers to be used in locating the plants on the plan. (m) All required yards shall be landscaped and maintained at all times. (n) Redwood chips, decorative stone and other inorganic materials are not acceptable substitutes for ground cover or turf. (o) All trees in parking areas shall be placed in root barriers. (p) All planting areas must be designed with an automatic irrigation system. Modifications shall be allowed for dry climate landscapes. Pop-up sprinklers shall be used in all areas other than installations against foundations for the sake of public safety. Drip, bubbler, or other low gallonage systems may be used in buffer areas and narrow strips. Sleeving must be called out wherever irrigation pipes are installed under hardscape. (q) The landscaping shall be contained in planting areas that are enclosed by minimum six-inch high concrete curbs. (r) Landscaping shall be installed and maintained in compliance with article XVI of this chapter, pertaining to water conservation. (s) Compliance with all provisions of this section shall be required except for minor modifications approved by the planning division. (t) All appurtenances, such as transformers, backflow preventers, trash enclosures, signage, meters, and lights, shall be shown on landscape plans and screened with plant materials.
(Code 1952, § 9230.286; Ord. No. NS-455, § 1, 6-20-60; Ord. No. NS-1301, § 3, 4-5-76; Ord. No. NS-2275, § 14, 12-18-95; Ord. No. NS-2801, § 10, 12-23-09)
Ask a question about Santa Ana law
Corpus searches the Santa Ana sections it holds and shows the ones that match, with their citations. Free, no sign-in.