Sec. 8-211. - Special commercial building provisions.

(a) Swinging exterior glass doors, wood or metal doors with glass panels, solid wood or metal doors shall be constructed or protected as follows: (electronic sliding doors are prohibited) (1) Wood doors shall be of solid core construction with a minimum thickness of one and three-fourths (1¾) inches. Hollow metal doors shall be constructed of a minimum equivalent to sixteen (16) U.S. gauge steel and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around the locking device. (2) Except when double cylinder deadbolts are utilized or safety glazing is required by Chapter 54 of the Uniform Building Code, any glazing installed within forty (40) inches of any door locking mechanism shall be constructed or protected as follows: a. Fully tempered glass or rated burglary resistant glazing; or b. Iron or steel grills of at least one-eighth (⅛) inch mesh secured with nonremovable bolts on the inside of the glazing may be utilized; and framing for iron or steel grills shall be by one (1) inch by one-fourth (¼) inch flat metal secured by nonremovable bolts; or c. The glazing shall be covered with iron or steel bars of at least one-half (½) inch round or one (1) inch by one-fourth (1 x ¼) inch flat metal, spaced not more than five (5) inches apart and secured with nonremovable bolts. d. Items b. and c. above shall not interfere with the operation of opening windows if such windows are required to be openable by the Uniform Building Code. (b) All swinging exterior doors with the exception of aluminum frame swinging doors shall be equipped as follows: (1) A single or double door shall be equipped with a double or single cylinder deadbolt. The bolt shall have a minimum projection of one (1) inch and be constructed so as to repeal cutting tool attack. The deadbolt shall have an embedment of at least three-fourths (¾) inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five (5) pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth (¼) inch in diameter. All deadbolts will be equipped with a locked indicator. Exposed installation screws on double cylinder deadbolts shall be nonremovable. The provisions of this subsection do not apply where (1) panic hardware is required, or (2) an equivalent device is approved by the enforcing authority. Locking devices shall be mounted at a height of not less than thirty (30) nor more than forty-four (44) inches above the finished floor. (2) Hinges for outshowing doors shall be equipped with nonremovable hinge pins or a mechanical interlock to preclude removal of the door from the exterior by removing the hinge pins. (3) Whenever a mail slot is located within forty (40) inches of the primary locking device on any exterior door it shall be covered by an interior hood which will discourage manipulation of the primary locking device. (4) Strikeplates shall be constructed of minimum sixteen (16) U.S. gauge steel, bronze or brass, a minimum of three and one-half (3½) inches in length and secured to the jamb with screws a minimum of two and one-half (2½) inches in length. (c) All exterior double doors shall be equipped as follows: (1) The inactive leaf of double doors shall be equipped with automatic releasing metal flushbolts having a minimum embedment of five-eighths (⅝) inch into the header and threshold of the door frame or by panic hardware which contains a minimum of two (2) locking points, one (1) located at the header the other at the threshold of each door. (2) Double doors shall have a full length astragal, constructed of steel a minimum of .125 inch thick which will cover the opening between the doors. The astragal shall be a minimum of two (2) inches wide, and extent a minimum of one (1) inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with nonremovable bolts spaced apart on not more than ten (10) inch centers. (d) Aluminum frame swinging doors shall conform to the following: (1) The jamb on all aluminum frame swinging doors shall be so constructed or protected to withstand one thousand six hundred (1,600) pounds of pressure in both a vertical distance of three (3) inches and a horizontal distance of one (1) inch each side of the strike, so as to prevent violation of the strike. (2) Aluminum frame swinging doors shall be equipped with a two-point locking mechanism consisting of deadbolt having a minimum bolt projection of one and one-half (1½) inches, or a hook shaped or similar bolt that engages the strike sufficiently to prevent spreading and a metal automatic releasing threshold bolt having a minimum embedment of five-eighths (⅝) inch into the floor. The deadbolt lock shall have a minimum of five (5) pin tumblers, and a cylinder guard and shall be equipped with a locked indicator. (e) Panic hardware, whenever required by the Uniform Building Code or Title 24, California Administrative Code, shall be equipped and installed as follows: (1) Panic hardware shall contain a minimum of two (2) locking points on each door, one (1) located at the header, the other at the threshold of the door; or (2) On single doors, panic hardware may have one (1) locking point which is not to be located at either the top or bottom rails of the door frame. The door shall have an astragal constructed of steel .125 inch thick which shall be attached with nonremovable bolts to the outside of the door. The astragal shall extend a minimum of six (6) inches vertically above and below the latch of the panic hardware. The astrogal shall be a minimum of two (2) inches wide and extend a minimum of one (1) inch beyond the edge of the door to which it is attached. (3) Double doors containing panic hardware shall have a full length astragal constructed of steel, attached to the doors at their meeting point which will close the opening between them, but not interfere with the operation of either door. (f) Installation and construction of frames and jambs for exterior swinging doors shall be as follows: (1) Door jambs shall be installed with solid backing in such a manner that no voids exist between the strike side of the jamb and the frame opening for a vertical distance of six (6) inches each side of the strike. Finger joints are prohibited. (2) In wood framing, horizontal blocking shall be placed between studs at door lock height for three (3) stud spaces each side of the door openings. Trimmers shall be full length from the heads to the floor with solid backing against sole plates. (g) In multiple occupancy office buildings all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors. (h) In multiple occupancy buildings, interior walls dividing the individual suites shall not end at the false ceiling but shall continue to the real roof. (i) Exterior transoms or windows shall be deemed accessible if less than twelve (12) feet above ground or adjacent to any pedestrian walkway. Accessible windows and transoms having a pane or opening exceeding ninety-six (96) square inches, with the smallest dimension exceeding six (6) inches, and not visible from a public or private thoroughfare shall be protected in the following manner: (1) Fully tempered glass or burglary resistant glazing; or (2) The following window barriers may be used but shall be secured with bolts, which are nonremovable from the exterior: a. Interior or exterior steel or iron bars of at least one-half (½) inch round or one by one-quarter (1 x ¼) inch flat metal spaced not more than five (5) inches apart and securely fastened; or b. Interior or exterior iron or steel grills of at least one-eighth (⅛) inch metal with not more than a two (2) inch mesh and securely fastened. (3) The protective bars or grills shall not interfere with the operation of opening windows if such windows are required to be openable by the Uniform Building Code. (j) Roof openings shall be equipped as follows: (1) All skylights on the roof of any building or premises used for business purposes shall be provided with: a. Rated burglary resistant glazing; or b. Iron or steel bars of at least one-half (½) inch round or one by one-fourth (1 x ¼) inch flat metal spaced not more than five (5) inches on center to cross the narrowest dimension of the opening being covered. If the narrowest dimension of that opening exceeds eighteen (18) inches, cross members shall be welded into place, not more than eighteen (18) inches apart beginning with a cross member at the center of the opening. Cross members shall be welded to each and every bar it crosses. The entire bar assembly shall be mounted inside the skylight and shall be attached to the building structure by means of machine bolts spaced not more than sixteen (16) inches apart or attached by means of an equivalent method approved by the enforcing authority; or c. A steel or iron grill of at least one-eighth (⅛) inch metal with a maximum two (2) inch mesh mounted inside the skylight and secured by bolts which are nonremovable from the exterior. d. These requirements do not apply on any structure with a height of thirty-five (35) feet or more where there is no readily available roof access as determined by the enforcing authority. (2) All hatchway openings on the roof or any building or premises used for business purposes shall be secured as follows: a. If the hatchway is of wooden material, it shall be covered on the inside with at least sixteen (16) U.S. gauge sheet steel, or its equivalent, attached with screws. b. The hatchway shall be secured from the inside with a slide bar or slide bolts which are attached by nonremovable bolts. c. Outside hinges on all hatchway openings shall be provided with nonremovable pins when using pin-type hinges. (3) All air duct or air vent openings exceeding ninety-six (96) square inches on the roof or exterior walls of any commercial building shall be secured by covering same with either of the following: a. Iron or steel bars of at least one-half (½) inch round or one by one-fourth (1 x ¼) inch flat metal spaced no more than five (5) inches apart and securely fastened; or b. Iron or steel grills of at least one-eighth (⅛) inch metal with a maximum two (2) inch mesh and securely fastened. c. If the barrier is on the outside, it shall be secured with bolts which are nonremovable from the exterior. d. The above must not interfere with venting requirements, creating potentially hazardous conditions to health and safety, or conflict with the provisions of the Uniform Building Code or Title 19, California Administrative Code. (k) Permanently affixed ladders leading to roofs shall be fully enclosed with sheet metal to a height of ten (10) feet. This covering shall be locked against the ladder with a case hardened hasp, secured with nonremovable screws or bolts and a padlock with a minimum three-eighth (⅜) inch hardened steel shackle, locking at both heel and toe, and a minimum five (5) pin tumbler operation with nonremovable key when in an unlocked position. Hinges on the cover will be provided with nonremovable pins when using pin-type hinges. (l) A building located within eight (8) feet of utility poles, trees or similar structures which allow access to the building's roof, windows or other openings shall have such access area barricaded or fenced with materials to deter human climbing. (m) The following standards for lighting and address markings shall apply to commercial buildings: (1) The address number of every commercial building shall be located and displayed so that it shall be easily visible from the street. The numerals in these numbers shall be no less than six (6) inches in height and be of a color contrasting to the background. In addition, any business which affords vehicular access to the rear through any driveway, alleyway or parking lot shall also display the same numbers on the rear of the building. (2) All exterior doors shall be equipped with a lighting device which shall provide a minimum maintained one (1) footcandle of light at ground level during hours of darkness. Lighting devices shall be protected by vandal resistant covers. (3) All parking lots, and access thereto, providing more than ten (10) parking spaces and for use by the general public, shall be provided with a minimum maintained one (1) footcandle of light on the parking surface from dusk until the termination of business every operating day. At all other hours of darkness, a minimum maintained .25 footcandles of light shall be provided at ground level. (4) Exterior lighting shall not shine away from subject property. (n) Interior night lighting shall be maintained in those areas that are visible from the street (ground floors only). (o) All exterior block wall fencing shall have intervals providing visibility corridors which will allow visibility of the interior from outside the wall, and these visibility corridors shall be placed at regular intervals. This applies only to block walls visible from the street. (p) Passenger elevators, the interiors of which are not completely visible when the car door(s) is open, shall have mirrors so placed as to make visible the whole of the elevator interior to prospective passengers outside the elevator. (q) When access to or within a commercial complex is unduly difficult because of secured openings or where immediate access is necessary for life saving or fire fighting purposes, a key override is to be installed in an accessible location. The key override shall be mastered to both the fire department and police department keys. (r) Any structure four (4) stories in height or greater will have a repeater installed in its roof. (s) Establishments having specific type inventories shall be protected by the following alarm service: (1) Silent alarm system with a central station hook-up and required twenty-four-hour supervised service: a. Jewelry store—Manufacturing, wholesale or retail. b. Any establishment manufacturing, storing or selling firearms and ammunition. c. Establishments selling or storing wholesale liquor, tobacco or drugs. d. Facilities selling or storing furs. e. Precious metal storage facilities. f. Banks, savings and loan institutions and credit unions. (2) Silent alarm system not requiring a central station hookup or supervised service: a. Liquor stores. b. Pawnshops. c. Establishments manufacturing, storing or selling electronic equipment. d. Establishments dealing in coins and stamps. e. Establishments manufacturing, storing or selling industrial tool supplies. f. Establishments manufacturing, storing or selling cameras. (3) Local or audible alarm system: a. Antique dealers. b. Art galleries. c. Service stations. d. Food markets. (4) Nothing in this subsection shall preclude the use of an alarm system providing a higher level of security than that which is required.

(Ord. No. NS-1424, § 1, 6-5-78; Ord. No. NS-1502, § 1, 10-1-79; Ord. No. NS-1794, § 7, 10-14-85)

Ask a question about Santa Ana law

Corpus searches the Santa Ana sections it holds and shows the ones that match, with their citations. Free, no sign-in.