For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.08.050 — Service—For New Divisions of Land

Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 15.08.050

Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/f3d4502d-85fe-4a19-878c-76da1b2d0619

§ 15.08.050: Service—For New Divisions of Land.

A. Plans and specifications for water system improvements for new divisions of land shall be submitted to the engineer to ensure that the improvements will meet the requirements of this Division 1. B. 1. Before requesting the issuance of a final subdivision map clearance, the subdivider shall deposit with the City a sum estimated by the engineer to cover the actual cost of reviewing documents verifying fire requirements, reports, security improvements and conducting field investigations. If technical reviews of plans for water systems are required as determined by the engineer, the subdivider shall pay water main plan check fees in accordance with the following schedule: Water Main Plan Check Lineal Feet of Water Mains and/or Hydrant Laterals | Charge 1 to 150 | $245.00 151 to 500 | 680.00 501 to 1,000 | 1,230.00 1,001 to 2,000 | 1,430.00 2,001 to 3,000 | 1,640.00 3,001 to 4,000 | 1,850.00 4,001 to 5,000 | 2,050.00 2. For each 1,000 feet of water main, or fractional part thereof, in excess of 5,000 feet, an additional $160.00 shall be added. C. Plan Check for Booster Pump Station, Reservoirs, etc. To check the plans and specifications for the construction of water pumping plants and reservoirs), the charge shall be $1,200.00 plus a charge of 0.15 percentage of the estimated construction cost thereof; provided, however, that such a charge shall not be applied to a public water district or other local agency where such a charge is prohibited by the provisions of Section 53091 of the Government Code. E. The required water system plans and specifications shall include: 1. A statement from the serving water utility that the proposed water system will be operated by the water utility and that, under normal operating conditions, the system will meet the requirements of this Division 1. 2. Other evidence satisfactory to the engineer showing that the proposed system can be operated by a water utility and that adequate water can be supplied to said system in accordance with this Division 1. F. The water system improvements may include construction of source of supply facilities, water mains, booster pumping stations, reservoirs, and any other facilities necessary to provide the required flow for the duration required by the Fire Department. G. The Fire Department may require that fire hydrants be installed to meet the flow requirements established pursuant to Section 15.16.060.

( Ord. 88-24 , 6/9/1988 ; amend Ord. 90-18 , 7/24/1990 )

Ask a question about Santa Clarita law

Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.